Component/FRU Removal and Replacement
2097937-002 Rev G
T2100-ST1 Treadmill, 110V / T2100-ST2 Treadmill, 220V
125
11 March 2019
o
Ratchet
o
Ratchet extension 6”
o
(2X) Medium length long nose pliers
o
Wire Cutters or Utility knife
o
Pliers or adjustable wrench
Accessories
o
Grounded wrist strap
o
Service Grease (PN 2097829-072 tube received with treadmill)
o
Tape measure
o
Computer or laptop
o
Calibration Program (T2100-ST Series Calibration Software)
o
Stop watch or watch with a second hand
o
Chalk or some other temporary marking device
o
Serial or USB Communication Cable
Replacing the Hood
Tools Required
o
1/4” Hex Socket or Flat Blade Screw Driver
Approximate time to complete: 10 min
1.
Turn the treadmill’s power switch to the OFF position.
2.
Unplug the treadmill from the wall receptacle.
3.
Allow the treadmill to discharge for 1 minute.
4.
Remove the 5 hood-securing screws (2 on the front and 3
on the back side of the treadmill).
5.
Remove the hood and set it aside.
6.
Reverse the procedure to reinstall hood.
(5) Screw HHWHTS #8-32 x 3/8” Long