background image

About the water softener system.

1.

To enter diagnostics, press and hold 
the 

MODE

button for 3 seconds until 

the Low Salt Alarm screen shows.

2.

Press the 

MODE

button 2 times 

to advance through Low Salt Alarm 
and Salt Efficiency options. See

Programming the Control

for 

details on these two options.

3. OPERATION OF DIAGNOSTICS

• Valve Position – 

Press the 

RECHARGE

button to initiate

a recharge cycle. Press again to manually index valve to
next position. See 

Service: Manually Advance Recharge

Check

for details.

0 – Service
1 – Fill
2 – Brine
3 – Backwash
4 – Fast Rinse

• Motor Operation – 

Two dashes will circulate around 

when motor should be running.

• Position Switch Operation – 

– Closed

– 

valve rotating to next position

– Open

– 

valve in position, service, fill, brine, etc.

• Water Meter – 

Indicates whether water is flowing 

through valve.

– 000 indicates no water is flowing through the valve

– Open nearby soft water faucet

– 000 to 141 (continual) shows water is flowing. Display

repeats for each gallon of water passing through the
meter. Control will beep at every gallon.

– If there is no reading in the display, with faucet open,

check the sensor. Pull the sensor from the valve outlet
port, and pass a small magnet in front of the sensor.
Counter should index in the display. If counter does
not index, check to make sure harness is connected 
to board properly. If there is a reading in the display,
there may be a problem associated with the turbine.
Turn off water supply, close the bypass valve and
disconnect bypass valve from body. Check turbine 
for binding or restriction due to debris. If this does 
not correct the problem, the Timer, Sensor or Turbine
may require replacement.

4. 

Historical data about the softener is available.

• Press and hold the UP 

button to display the number 

of days this control has had electrical power applied.

• Press and hold the DOWN 

button to display the

number of recharges initiated by this control since the
model code number was entered.

5.

Press the 

MODE

button to return to normal operation 

and display.

Service: Set Model Code

1.

To change or check model code, first press and hold the

MODE

button for 3 seconds until the Low Salt Alarm screen

shows.

2.

Press and hold the 

MODE

button again 

for 3 seconds. A display with 

at 

the top will appear.

3.

Press the UP 

or DOWN 

buttons to

select the correct model code.

F18–GXSF18G

4.

Press the 

MODE

button one time to return to normal

operation and display. If the model code was changed:

• the display will go blank momentarily, then display the

model code entered.

• the display will then return to the set present time display,

and the blue indicator light will flash. The control will have
to be reprogrammed. See 

Programming the Control

.

NOTE:

If the control is left in any of the above diagnostic

displays, or a flashing display when setting time, hardness,
etc., it will revert back to the normal display in 4 minutes.

Service: Manually Initiated Electronics Diagnostics

SALT

LEVEL

SALT

LEVEL

SALT

LEVEL

Water meter

Valve
position

Position
switch

Motor

Motor

Turbine

Turbine support
and shaft

Sensor
housing

Position
switch

Valve
outlet

18

Содержание SmartWater GXSF18G

Страница 1: ...spañol empieza en la página 33 Sistema Suavizante de Agua ge com 7289396 215C1173P027 49 50182 07 06 JR Write the model and serial numbers here Model ________________ Serial ________________ To find these numbers lift the cover and look on the rim below the control panel Model GXSF18G Owner s Manual Installation Instructions Water Softening System System tested and certified by NSF International a...

Страница 2: ...ROPER INSTALLATION Install or store where it will not be exposed to temperatures below freezing or exposed to any type of weather Water freezing in the system will break it Do not attempt to treat water over 100 F Do not install in direct sunlight Excessive sun or heat may cause distortion or other damage to non metallic parts Properly ground to conform with all governing codes and ordinances Use ...

Страница 3: ... Use care when handling the softener Do not turn upside down drop drag or set on sharp protrusions Maximum allowable inlet water pressure is 125 psi If daytime pressure is over 80 psi nighttime pressure may exceed the maximum Use a pressure reducing valve if necessary Adding a pressure reducing valve may reduce the flow The softener works on 24 volt 60 Hz electrical power only Be sure to use the i...

Страница 4: ...an be ordered from GE Parts at 800 626 2002 part number WS07X10004 If a rigid valve drain is needed to comply with plumbing codes you can buy the parts needed to connect a 1 2 copper tubing or plastic pipe drain See Step 4 Clean nugget or pellet water softener salt is needed to fill the brine tank See Step 8 WHERE TO INSTALL THE SOFTENER Place the softener as close as possible to a sewer drain or ...

Страница 5: ...ES HERE Brinewell O rings 2 1 NPT male adapter 2 Clips 2 1 female adapter 2 not supplied Clips O rings 2 INLET Hard water to outside faucets Fig 1 CROSSOVER Use if water supply flows from the left Include single or 3 valve bypass Hard water From softener outlet Soft water To softener inlet OPTIONAL 3 VALVE BYPASS INSTALLATION ILLUSTRATION Bypass valve Hard water to outside faucets Inlet valve Outl...

Страница 6: ...NOTE For easier installation remove the top cover Slide the salt hole cover open Locate the top cover release point Pull gently on the top cover at the release point lift up and rotate top cover backward to remove Remove all packing material located under top cover Turbine Valve outlet Turbine shaft and support NOTE Be sure the turbine and support are firmly in place in the valve outlet Blow into ...

Страница 7: ...tions to the bypass valve and snap clips into place Be sure the clips for the bypass valve and NPT adapters snap into place Pull on the bypass valve and NPT adapters to make sure the parts are held securely in place 3 Installation Instructions 7 IN OUT Turn bypass valve upside down to connect to floor level plumbing CONNECT AND RUN THE VALVE DRAIN HOSE Use the provided drain hose 20 length include...

Страница 8: ...on Instructions 8 LAUNDRY TUB SUMP STANDPIPE Clip 1 4 NPT threads 1 2 O D copper tube not provided Compression fitting 1 4 NPT x 1 2 O D tube not provided Cut barbs from drain fitting Barbs INSTALL THE BRINE TANK OVERFLOW FITTINGS AND HOSE Insert the rubber grommet into the 3 4 diameter hole in the brine tank sidewall as shown Push the end of the hose adapter elbow into the grommet as shown Attach...

Страница 9: ...found Be sure to observe previous caution notes Turn on the gas or electric supply to the water heater Light the pilot if applicable 7 ADD WATER AND SALT TO THE BRINE TANK Reinstall top cover assembly align cover with the top of the softener Push down to snap cover into place Open the salt hole cover and squeeze the top cover and the blue rim together near the top cover release point to completely...

Страница 10: ...t model A beep sounds while pressing buttons for control programming One beep signals a change in the control display Repeated beeps mean the control will not accept a change from the button you have pressed and you should select another button To program the control you will use the UP DOWN and MODE buttons Use the MODE button to scroll arrow to desired control function SET PRESENT TIME OF DAY 1 ...

Страница 11: ...e of brine well inside brine tank see illustration on page 5 3 Press UP or DOWN button to set the SALT LEVEL to correspond to level on yellow indicator in brine tank NOTE Each press of a button changes the level by increments of 0 5 up to 8 0 As the number increases the salt level bars increase on each whole number Lowering the salt level below zero turns the SALT LEVEL indicator OFF 4 Press the M...

Страница 12: ...ODE button to return to the normal run display SALT LEVEL SALT LEVEL E SALT LEVEL SIGNALS LOST TIME SIGNAL If time is lost on the display due to power interruption the blue indicator light will flash 4 times every second until the present time of day is entered LOW SALT SIGNAL When the DAYS TO EMPTY drops to 15 the blue indicator light and DAYS TO EMPTY in the display will flash every second and t...

Страница 13: ...o illustration on page 5 3 IMPORTANT Press and hold for 3 seconds the faceplate RECHARGE button to start an immediate recharge RECHARGE begins to flash in the display The bleach will be drawn through the water softener and out the drain This process takes approximately 2 hours 4 If after sanitization water from the house faucet tastes salty or has a slight color this is a preservative from the res...

Страница 14: ...ll with the hard water Automatic Hard Water Bypass During Recharge Fill Salt dissolved in water is called brine Brine is needed to clean the hard minerals from resin beads To make the brine water flows into the salt storage area during the fill stage Brining During brining brine travels from the salt storage area into the resin tank Brine is the cleaning agent needed to remove hard minerals from t...

Страница 15: ...nk during recharge If it becomes plugged with sand dirt etc the water softening system will not work and you will get hard water To get to the nozzle and venturi remove the water softening system top cover Be sure the water softening system is in service cycle no water pressure at nozzle and venturi Then while holding the nozzle and venturi housing with one hand remove the cap Lift out the screen ...

Страница 16: ...ng system begins an immediate recharge and when over in about two hours you will have a new supply of soft water Once started you cannot cancel this recharge Feature Optional Recharge Controls Feature Memory If electrical power to the water softening system is interrupted the control display is blank and the blue indicator light is off but the control keeps correct time for about 6 hours When powe...

Страница 17: ...ou are not getting soft water and an error code is not displayed use the procedures below to find the problem First make the following visual checks VISUAL CHECKS 1 Is there electrical power to the outlet the water softening system transformer is plugged into 2 Is there sufficient salt in the storage tank 3 Is the softener bypass valve directing water for soft water service 4 Is the valve drain ho...

Страница 18: ...ly close the bypass valve and disconnect bypass valve from body Check turbine for binding or restriction due to debris If this does not correct the problem the Timer Sensor or Turbine may require replacement 4 Historical data about the softener is available Press and hold the UP button to display the number of days this control has had electrical power applied Press and hold the DOWN button to dis...

Страница 19: ...salt See Care and cleaning of the water softening system section If the water softening system does not draw brine check nozzle and or venturi dirty or defective defective nozzle and venturi seal nozzle and venturi not seated properly on gasket other inner valve defect rotor seal rotor and disc wave washer etc restricted drain check drain fitting and hose NOTE If water system pressure is low an el...

Страница 20: ...amond Crystal Red Out brand salt Checking the Salt Storage Level and Refilling Your water softening system takes hardness minerals calcium and magnesium out of the water Also it can control some see the Specification Guidelines section clear water iron With clear water iron water from a faucet is clear when first put into a glass After 15 to 30 minutes the water begins to cloud or turn rust colore...

Страница 21: ...n Electrical outlet on a circuit that can NOTE The electrical outlet for the softener should be continuously be switched off live so it cannot be accidentally switched off Manual bypass valve in bypass position Be sure the bypass valve stem is positioned properly with the knob in the OUTposition Observe instructions on the decal at the end of the stem Valve drain hose pinched plugged Any restricti...

Страница 22: ...em section page 15 Water is blue color Acidic water in copper plumbing Have the water tested at once after water softening system was installed Water softening system Meter turbine stuck See the Service Manually Initiated Electronics Diagnostics not regenerating section for troubleshooting procedures page 18 Call for service Sensor wire not plugged into See the Service Manually Initiated Electroni...

Страница 23: ...from the unit This is normal into a drain during recharge Water has air bubbles Air in system after installation Will go away after it runs for a while and is cloudy Error Code on control Wiring may have worked loose See page 17 for details in the control Unplug transformer Remove control cover release clips on side Check for loose incorrect wiring connections to electronic board or switch Reconne...

Страница 24: ...24 Notes ...

Страница 25: ...25 Notes ge com ...

Страница 26: ...26 Notes ...

Страница 27: ...3 3 3 7 8 9 10 11 12 56 55 14 16 17 18 19 20 21 22 23 24 25 26 27 13 146 28 4 55 56 LITERATURE 999 5 37 38 39 27 Parts list ge com ...

Страница 28: ...28 Parts list ...

Страница 29: ...X10003 CLAMP HOSE 2 0026 WS22X10016 ADAPTER HOSE 1 0027 WS22X10017 GROMMET 1 0028 WS35X10035 GROUND CLAMP KIT 1 0029 WS15X10045 BRINE VALVE ASM 1 0030 WS35X10036 FLOAT STEM GUIDE 1 0031 WS03X10006 CLIP 1 0032 WS15X10006 VALVE BODY BRINE 1 0033 WS03X10007 CLIP 1 0034 WS03X10008 SCREEN 1 0035 WS07X10002 TUBING ASM 1 0036 WS07X10021 BRINE TUBE ASM 1 0037 WS31X10031 ELECTRONICS 1 0038 WS02X10029 SPACE...

Страница 30: ...N HOSE 1 0133 WS03X10021 O RING 5 8 X 13 16 1 0134 WS03X10022 PLUG FLOW RINSE CONTROL 1 0135 WS03X10023 CLIP 1 0136 WS26X10003 CAM GEAR 1 0137 WS26X10004 BEARING 1 0138 WS26X10005 PLATE MOTOR 3 4 1 0139 WS02X10015 SCREW 6 20 X 3 8 2 0140 WS26X10011 MOTOR ASM 1 0141 WS02X10016 SCREW 6 20 X 7 8 2 0143 WS60X10013 ADAPTER NPT THREADED STD VALVE 2 0145 WS60X10004 CLIP 4 0146 WS28X10017 HARNESS WIRE SEN...

Страница 31: ...damage caused by possible defects with this appliance its installation or repair Product not accessible to provide required service This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA If the product is located in an area where service by a GE Authorized Servicer is not available you may be responsible for a trip charge or ...

Страница 32: ...lated service costs original purchase Service trips to your home to teach you how to use the product Improper installation delivery or maintenance Failure of the product if it is abused misused altered used commercially or used for other than the intended purpose Use of this product where water is microbiologically unsafe or of unknown quality without adequate disinfection before or after the syst...

Страница 33: ...ones 49 Servicio 46 50 52 Sistema de descalcificación de agua 46 52 Cuidado y limpieza 53 Consejos para la solución de averías 54 56 Soporte al cliente Garantía 62 Lista de partes catálogo 58 61 Soporte al consumidor 63 Escriba aquí los números de modelo y de la serie Modelo No ________________ Serie No __________________ Para encontrar estos números levante la cubierta y mire en el borde debajo d...

Страница 34: ...e no quede expuesto a temperaturas por debajo del punto de congelación ni esté expuesto a ningún tipo de inclemencias atmosféricas Si el agua llega a congelarse dentro del sistema éste podría romperse No intente dar tratamiento al agua si se encuentra a una temperatura por encima de 38 ºC 100 ºF No instale expuesto a los rayos directos del sol Exposición al sol a calor excesivos podrían causar dis...

Страница 35: ... lo apoye en protuberancias La presión de entrada máxima permitida es de 125 psi Si la presión durante el día es por encima de 80 psi la presión nocturna podría exceder el máximo Use una válvula reductora de presión para reducir el flujo si es necesario Agregar una válvula reductora de presión podría reducir el flujo El sistema de descalcificación funciona solamente con 24 voltios 60 Hz Cerciórese...

Страница 36: ...l 800 626 2002 no de parte WS07X10004 Si necesita una válvula rígida de drenaje para cumplir con los códigos de plomería podrá comprar las partes necesarias para conectar un drenaje de tubería de cobre o plástico de 1 2 1 27 cm Consulte el Paso 4 Sal del descalcificador en una pepita limpia o bolita de agua es necesaria para llenar el tanque de agua salmuera Consulte el Paso 8 DONDE INSTALAR EL DE...

Страница 37: ...tóricos 2 ENTRADA Fig 1 VÍA DE ENLACE Úsela si el flujo de suministro fluye desde la izquierda Incluya una derivación sencilla o de 3 válvulas Agua dura Agua descalcificada Hacia la entrada del descalcificador ILUSTRACIÓN DE LA INSTALACIÓN OPCIONAL DE UNA DERIVACIÓN DE 3 VÁLVULAS Fig 2 VÍA DE ENLACE Úsela si el flujo de suministro fluye desde la izquierda Incluya una derivación sencilla o de 3 vál...

Страница 38: ...ierta de la sal hasta abrirla Localice el punto de liberación de la cubierta superior Tire ligeramente en la cubierta superior en el punto de liberación levante y rote la cubierta superior hacia atrás para remover Remueva todo el material de empaquetado localizado debajo de la cubierta superior Turbina Salida de la válvula Eje y soporte de la turbina NOTA Cerciórese de que la turbina y el soporte ...

Страница 39: ...ss y asegure los clips en su lugar Compruebe que los clips para la válvula de bypass y los adaptadores NPT se aseguran en su lugar Jale la válvula de bypass y los adaptadores NPT para verificar que las piezas se mantienen seguras en su lugar 3 Instrucciones de instalación 39 CONECTE Y HAGA FUNCIONAR LA MANGUERA DE DRENAJE DE LA VÁLVULA Use la manguera de drenaje se ha incluido una de 20 pies para ...

Страница 40: ...ador Para las presiones de entrada entre 20 y 50 psi no eleve más de 8 pies 2 67 m por encima del piso Para la presión de entrada por encima de 50 psi la manguera de drenaje podría levantarse a una altura máxima de 14 pies CÓMO CONECTAR UN TUBO DE DRENAJE DE VÁLVULA RÍGIDA Para adaptar un tubo de drenaje de cobre al descalcificador use una sierra de arco para cortar el extremo de púa del accesorio...

Страница 41: ...e llevar a cabo y repare inmediatamente si encuentra alguna Cerciórese de observar las notas de precaución anteriores Conecte el suministro de gas o eléctrico hacia el calentador de agua Encienda el piloto si es aplicable 7 AGREGUE AGUA Y SAL AL TANQUE DE SALMUERA Reinstale la ensambladura de la cubierta superior alinee la cubierta con la parte superior del descalcificador Empuje hacia abajo para ...

Страница 42: ...ego oprima el botón MODE modo para aceptar el modelo correcto Un bip sonará mientras usted oprime los botones para la programación del control Un bip significa un cambio en la pantalla de control Sonidos repetidos significan que el control no acepta un cambio del botón que usted ha oprimido y que usted debe oprimir otro botón Para programar el control usted usará los botones UP DOWN y MODE modo Ut...

Страница 43: ...ro del tanque de salmuera vea la ilustración de la página 37 3 Presione el botón UP o DOWN para fijar el SALT LEVEL nivel de sal que corresponda al nivel en el indicador amarillo en el tanque de salmuera NOTA Cada vez que presione el botón el nivel cambia en incrementos de 0 5 hasta 8 0 A medida que el número aumenta las barras del nivel de sal aumentan en cada número entero Disminuir el nivel de ...

Страница 44: ...LT LEVEL E SALT LEVEL SEÑALS SEÑAL DE HORA PERDIDA Si la hora se pierde en la pantalla debido a una interrupción en el suministro eléctrico la luz indicadora azul se enciende cuatro veces intermitentemente cada segundo hasta que se ingrese la hora actual del día SEÑAL DE BAJO NIVEL DE SAL Si la opción de la alarma de bajo nivel de sal está activada y la función DAYS TO EMPTY días hasta vacío está ...

Страница 45: ...TANTE Oprima y sostenga oprimido por 3 segundos el botón RECHARGE recarga del plato para comenzar una recarga inmediata El indicador de RECHARGE recarga aparece intermitente en la pantalla El cloro es llevado a través del descalcificador de agua Este proceso dura aproximadamente 2 horas 4 Si después de la desinfección el agua de la llave de la casa tiene un sabor salado o tiene un color ligero est...

Страница 46: ... es llamada salmuera La salmuera es necesaria para limpiar los minerales duros de las diminutas partículas de resina Para formar la salmuera el agua fluye hacia el interior del tanque de sal durante el período de llenado Salado Durante el proceso de salado la salmuera se desplaza del área del tanque de almacenamiento de la sal hacia el tanque de la resina La salmuera es el agente de limpieza neces...

Страница 47: ...puente de sal La sal debe estar floja desde arriba hasta el fondo del tanque Tome un palo de escoba o algo parecido y con cuidado empújelo hacia el interior del depósito de sal introduciéndolo y sacándolo Si el instrumento golpea un objeto duro cerciórese de que lo que golpea no es el fondo o las paredes laterales del tanque es posible que exista un puente de sal Con cuidado rompa el puente con el...

Страница 48: ...a hasta que estén limpios Si es necesario use un cepillo pequeño para remover el hierro o la suciedad También inspeccione y limpie la junta NOTA Algunos modelos tienen un pequeño tapón de flujo localizado en la boquilla y el Venturi y o un pequeño filtro en forma de cono en el alojamiento Cerciórese de inspeccionar y limpiar estas partes si su modelo está equipado con ellos Con cuidado reemplace t...

Страница 49: ...ecarga inmediata y cuando termine en unas dos horas usted tendrá un nuevo suministro de agua descalcificada Una vez haya iniciado usted no puede cancelar la recarga Función Controles opcionales de recargado Función Memoria Si el suministro eléctrico del sistema de descalcificación de agua es interrumpido la pantalla de control estará en blanco y la luz indicadora azul se apaga pero el control mant...

Страница 50: ...nte procedimiento para encontrar la fuente del problema Primero realice las siguientes inspecciones visuales INSPECCIONES VISUALES 1 Hay energía eléctrica entrando hacia el tomacorriente en el cual el transformador del sistema de descalcificación de agua está conectado 2 Hay suficiente sal en el tanque de almacenamiento 3 Está la válvula de bypass de descalcificación dirigiendo el agua para el ser...

Страница 51: ...e agua que pasar por el metro El control produce un sonido por cada galón Si no hay una indicación en la pantalla con el grifo abierto revise el sensor Hale el sensor del puerto de salida de la válvula y pase un pequeño imán por el frente del sensor El contador debe aparecer en la pantalla Si el contador no aparece revise para cerciorarse de que los cables están conectados correctamente al tablero...

Страница 52: ...var el llenado presione el botón RECHARGE recarga para llevar al sistema de descalcificación de agua al proceso de salado Un flujo lento de agua hacia el drenaje debe comenzar Verifique la extracción de la salmuera del tanque alumbrando con una linterna hacia el depósito de la salmuera y observando un goteo evidente en el nivel de líquido durante un período de tiempo extenso NOTA Cerciórese de que...

Страница 53: ...rystal Red Out Inspeccione el nivel de almacenamiento de la sal y el rellenado Su sistema de descalcificación de agua toma la dureza de los materiales calcio y magnesio y la extrae del agua También puede controlar una cantidad considerable del hierro del agua clara Consulte la sección Directrices de especificaciones Con hierro de agua clara el agua de un grifo es clara cuando se coloca en un vaso ...

Страница 54: ...TA El tomacorriente para el interruptor del El tomacorriente está en un circuito que descalcificador debe estar permanentemente conectado para que no no puede ser desconectado pueda ser desconectado accidentalmente La válvula de bypass manual está en Cerciórese de que la palanca de la válvula de bypass se encuentre la posición de bypass en la posición correcta con el botón en la posición OUT afuer...

Страница 55: ...a descalcificación de agua El sistema de El sistema de descalcificación de No usa tanta sal para regenerarse es muy eficiente descalcificación de agua agua es una unidad de demanda no está usando ninguna sal Posible puente de sal Consulte la sección Sobre el sistema de descalcificación de agua en la página 47 La boquilla o el Venturi Consulte la sección Sobre el sistema de descalcificación de agua...

Страница 56: ...nguera de drenaje restringida Limpie y reconecte la manguera Revise en busca de giros en la línea de drenaje Agua de color La unidad estuvo inoperante Complete los Procedimientos de desinfección de la página 45 café amarillo por un periodo de tiempo Las partículas de resina Distribuidor agrietado Llame para solicitar servicio aparecen en el agua potable y en los lavamanos Un sonido que usted Agua ...

Страница 57: ...57 Notas ge com ...

Страница 58: ...3 3 3 7 8 9 10 11 12 56 55 14 16 17 18 19 20 21 22 23 24 25 26 27 13 146 28 4 55 56 LITERATURE 999 5 37 38 39 Lista de partes 58 ...

Страница 59: ...59 ge com ...

Страница 60: ...0027 TORNILLO 1 0024 WS32X10023 TANQUE DE SALMUERA COMPACTO 1 0025 WS18X10003 ABRAZADERA DE LA MANGUERA 2 0026 WS22X10016 ADAPTADOR DE LA MANGUERA 1 0027 WS22X10017 ARANDELA DE GOMA 1 0028 WS35X10035 KIT DE ABRAZADERAS PARA 1 CONEXIÓN A TIERRA 0029 WS15X10045 ENSAMBLADURA DE LA VÁLVULA 1 DE LA SALMUERA 0030 WS35X10036 ENSAMBLADURA DE FLOTE 1 PALANCA Y GUÍA 0031 WS03X10006 CLIP 1 0032 WS15X10006 CU...

Страница 61: ... VENTURI 0130 WS35X10005 KIT DEL SELLO 3 4 1 0132 WS22X10023 ADAPTADOR MANGUERA 1 DE DRENAJE PARA DRENAJE 0133 WS03X10021 ARO TÓRICO 5 8 X 13 16 1 0134 WS03X10022 TAPÓN DE FLUJO CONTROL 1 DE ENJUAGUE 0135 WS03X10023 CLIP 1 0136 WS26X10003 LEVA Y ENGRANAJE 1 0137 WS26X10004 RODAMIENTO 1 0138 WS26X10005 PLATO DEL MOTOR 3 4 1 0139 WS02X10015 TORNILLO 6 20 X 3 8 2 0140 WS26X10011 ENSAMBLADURA DEL MOTO...

Страница 62: ... causada por defectos posibles de este electrodoméstico su instalación o reparación Producto no accesible para facilitar el servicio requerido Lo que no está cubierto Esta garantía se extiende al comprador original y cualquier comprador posterior de productos comprados para uso residencial dentro de Estados Unidos Si el producto está situado en un área que no dispone de servicio por parte de un pr...

Страница 63: ...amar al 800 626 2224 durante horas normales de oficina GE Consumer Home Services estará aún ahí cuando su garantía termine Piezas y accesorios ge com Aquellos individuos con la calificación necesaria para reparar sus propios electrodomésticos pueden pedir que se les manden las piezas o accesorios directamente a sus hogares aceptamos las tarjetas VISA MasterCard y Discover Haga su pedido en línea h...

Страница 64: ...ffect You can purchase it on line anytime or call 800 626 2224 during normal business hours GE Consumer Home Services will still be there after your warranty expires Parts and Accessories ge com Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes VISA MasterCard and Discover cards are accepted Order on line today 24 hours every day or by...

Отзывы: