background image

15

10

5

0

5
10

10

5

0

5

10

Hot or cold air directed
onto sensor

Pets

Intermittent
heat sources

Windows

Figure 3.

Cross  traffic

Figure 4.

Blocking coverage pattern

6150-ID SHARPSHOOTER

 PIR

installation instructions

Sunlight or
reflected sunlight

Description

The 6150-ID (Figure 1) is an addressable PIR device that
interfaces with the PinPoint system. This system provides
flexible and reliable two-way communication between the
device and the controller.

Mounting location

Avoid false alarm sources (Figure 2)
The unit should not “see” sources of heat or cold. For
false alarm free operation, no part of an unwanted hot
spot should enter any part of a zone.

Locate for cross traffic (Figure 3)
Place the unit where intruders move across the beams,
not toward the unit. For best detection, an intruder
should cross the entire zone.

Do not block the coverage pattern (Figure 4)
The unit requires a clear line of sight. Inform end-users
not to block the coverage pattern with inventory or
furniture.

Figure 1. Exploded view

g

Figure 2.

False alarm sources

Sliding LED cover

Standard lens
(Masking kit included)

Swivel mounting bracket

#8 x 3/4"(2cm) screw
for ball joint shoe

Front cover

Two #6 x 3/4"(2cm) screws for
mounting the bracket or case
(Two #6 wall anchors are
included for sheet rock mounting)

Mounting knockouts

Lens shield/circuit
board assembly

Base

LED

Содержание SHARPSHOOTER 6150-ID

Страница 1: ...false alarm free operation no part of an unwanted hot spot should enter any part of a zone Locate for cross traffic Figure 3 Place the unit where intruders move across the beams not toward the unit For best detection an intruder should cross the entire zone Donotblockthecoveragepattern Figure4 The unit requires a clear line of sight Inform end users not to block the coverage pattern with inventory...

Страница 2: ...ensitivity DIP switches Figure 6 See DIP switches 5 Set the PinPoint address DIP switches Figure 6 Devices are shipped with DIP switches set to 255 This is an invalid address The device will not communicatewiththecontrollerandthewalktest LEDwillnotlightuntilavalidaddresshasbeenset Refer to the controller s manual to determine the correct address setting for each unit 6 Pull the PinPoint wiring thr...

Страница 3: ...curtain applications It requires the intruder to only pass through one curtain to triggeranalarm Notes Operation in the standard curtain mode is for the specified ranges of 33 feet 10 1m and 45 feet 13 7 m For operation in bi curtain mode the unit has 30 feet 9 1m of range only For ranges from 30 to 45 feet 9 1 to 13 7 m the unit will provide detection within 6 steps or 14 feet 4 3 m across the pl...

Страница 4: ...tain areas are entered The LED visible on the front cover lights to indicate an alarm 4 Walk test the detection pattern and make any necessary adjustments 5 Replace and walk test the unit to verify the unit is communicatingwiththecontroller Note After the walk test mode times out in 3 to 4 minutes the unit returns to normal operating mode In normal operating mode the unit LED is disabled to reduce...

Страница 5: ...t 6 1m 20ft 6 1m 6ft 10in 2 1m 0 Topview Sideview Figure 15 Pet alley 35ft 10 7m 0 35ft 10 7m 35ft 10 7m 0 3 ft 3 in 1 0m Topview Sideview 45ft 13 7m 40ft 12 2m 30ft 9 1m 20ft 6 1m 10ft 3 0m 0 0 10ft 3 0m 20ft 6 1m 30ft 9 1m 40ft 12 2m 45ft 13 7 m 6ft 10in 2 1m 60 30 15 Topview 4 Sideview 36 36 0 6 6ft 10in 2 1m 7ft 6in 2 3m 9ft 2 7m 90 27 5m Topview Sideview ...

Страница 6: ...tional 20 ft x 140 Listings FCC CE GE Security 12345 SW Leveton Drive Tualatin OR 97062 503 692 4052 USA Canada 800 547 2556 Tech Support 800 648 7424 www gesecurity com 1042134 Rev B September 2004 FCC compliance This device complies with Part 15 of the FCC rules Operation is subject to the following conditions 1 This device may not cause harmful interference 2 This device must accept any interfe...

Отзывы: