Performance RHM 100
Max Flow Rate Qmax = 12,000 kg/min (26,455 lb/min) and Qnom (*) = 10,000 kg/min (22,046 lb/min)
Standard Models
Flow Rate
Uncertainty
kg/min
lb/min
in % of reading
12000
26455
0.20
6000
13228
0.20
3000
6614
0.20
800
1764
0.20
300
661
0.50
Goldline Models (**) - selected sensors
Flow Rate
Uncertainty
kg/min
lb/min
in % of reading
9000
19842
0.15
7000
15432
0.15
5000
11023
0.15
3000
6614
0.15
1800
3968
0.15
Low Flow Models (**) - selected sensors
Flow Rate
Uncertainty
kg/min
lb/min
in % of reading
12000
26455
0.20
6000
13228
0.20
800
1764
0.20
300
661
0.50
200
441
0.60
Uncertainty % DP (bar)
Flow Rate kg/min
Uncertainty % DP (bar)
Flow Rate kg/min
Uncertainty % DP (bar)
Repeatability
Better ± 0.1% of rate,
Goldline 0.05%
Density
Down to 0.5% uncertainty
Temperature
Better ± 1°C
Flow Rate kg/min
(*) Nominal flow Qnom refers to roughly 8 - 10 m/s
(26 - 33 ft/s) velocity in measuring loops for best
performance.
(**) Selected sensors are only available in combination
with temperature options T1, TA, standard material and
pressure range.
• Uncertainty of reading (incl. zero drift) indications refer
to reference conditions H
2
O, 18-24°C (66 - 76°F), 1 - 3
bar (15 – 45 psi) and installation according to field
manual.
• Calibration at factory only up to 11,000 kg/min.
• Pressure drop indications refer to H
2
O, with measuring
loops type P0.
• For calibration to customer range and / or with
improved uncertainty, please consult your local
agent.