background image

General Dimensions RHM 03

3

PF0

 (parallel, sealless construction with flange connection)

Process Connection

Face to face length (L)  Order Code

mm

in

Standard

Flange DIN DN15/PN40

220

8.66

D1

Flange DIN DN15/PN100

220

8.66

D2

Flange ANSI ½" 150# RF/SF 

220

8.66

A1

Flange ANSI ½" 300# RF/SF 

220

8.66

A2

Flange ANSI ½'' 600# RF/SF 

220

8.66

A3

Flange ANSI ½" 1500# RF/SF

300

11.81

A6

Flange ANSI ½'' 1500# RTJ 

300

11.81

R1

Optional

Flange DIN DN15 / PN 160

220

8.66

D3

Flange DIN DN25 / PN 40

260

10.24

D4

Flange ANSI ½" 2500# RF/SF

300

11.81

A8

Flange ANSI ½'' 2500# RTJ

300

11.81

R2

Flange JIS RF 10k 15A (1/2")

220

8.66

J1

Flange JIS RF 20k 15A (1/2")

220

8.66

J2

Grayloc Hub 1 GR4 (1")

300

11.81

H3

Type parallel, welded measuring loops without seals and flange connection

PFT/SFT/SHT 

(parallel/serial, sealless construction with 

thread connection) 

 

 

Type PFT/SFT/SHT - welded measuring loops without seals and thread connection

Process Connection

Face to face length (L)  Order Code

mm

in

Standard

PFT/SFT

Female Thread G ¼"

220

8.66

G1

Female Thread ¼" NPT

220

8.66

N1

Swagelok ¼" tube inlet (SS-

400-1-4W)

300

11.81

W1

Standard

SHT

Female Thread ¼" NPT

220

8.66

N1

Autoclave 3/8" MP (9/16-18 

UNF female thread)

220

8.66

P2

A1 = 130 mm (5.12 in)   

B1 = 25 mm (0.98 in) 

 

Terminal box (without cable gland) 125 x 80 x 58 mm (4.92 x 3.15 x 2.28 in) 

A2 = 145 mm (5.71 in)   

B2 = 40 mm (1.57 in) 

 

W = 0 mm for Temperature Range T1 and TA 

 

 

H1 = 173 mm (6.79 in)   

 

 

 

W = 100 mm (3.94 in) for Temperature Range T2, T3 and T4 

H2 = 205 mm (8.07 in)   

 

 

 

 

 

       

       

For weights and packaging dimensions please see last page of this section. 

 

 

 

 

 

 

Содержание RHM 03

Страница 1: ...r Typical measuring ranges from 0 05 kg min to 5 kg min Minimal flows as low as 38 g min Versatile Coriolis Mass Flowmeter for Low Flow and Very High Pressure Applications Customization possible Extra compact design with minimal space requirement Hazardous Area Approvals ATEX CSA Advantages Torsion oscillator design assures most stable and basically drift free measurement and increased signal to n...

Страница 2: ... in PHH parallel very high pressure manifold construction Process Connection Face to face length L Order Code mm in PM0 SM0 Standard Female Thread G 50 1 97 G1 Female Thread NPT 50 1 97 N1 PH0 SH0 Standard Female Thread G 70 2 76 G1 Female Thread NPT 70 2 76 N1 Autoclave 3 8 MP 9 16 18 UNF female thread 70 2 76 P2 Type parallel very high pressure manifold with PTFE seals and thread connection orie...

Страница 3: ...81 H3 Type parallel welded measuring loops without seals and flange connection PFT SFT SHT parallel serial sealless construction with thread connection Type PFT SFT SHT welded measuring loops without seals and thread connection Process Connection Face to face length L Order Code mm in Standard PFT SFT Female Thread G 220 8 66 G1 Female Thread NPT 220 8 66 N1 Swagelok tube inlet SS 400 1 4W 300 11 ...

Страница 4: ...DN25 PN 40 260 10 24 D4 Flange DIN DN25 PN160 260 10 24 D5 Flange JIS RF 10k 15A 1 2 220 8 66 J1 Flange JIS RF 20k 15A 1 2 220 8 66 J2 A1 130 mm 5 12 in B1 25 mm 0 98 in Terminal box without cable gland 125 x 80 x 58 mm 4 92 x 3 15 x 2 28 in A2 145 mm 5 71 in B2 40 mm 1 57 in W 0 mm for Temperature Range T1 and TA H1 173 mm 6 79 in W 100 mm 3 94 in for Temperature Range T2 T3 and T4 Weight in stan...

Страница 5: ...3 x 0 4 mm 0 12 x 0 016 in bar C psi F 460 50 6672 122 390 120 5656 248 320 210 4641 410 256 350 3713 662 pmax of PA measuring loops low DP version M0 standard material 1 4539 904 L OD x WT 3 x 0 3 mm 0 12 x 0 012 in bar C psi F 270 50 3916 122 200 120 2901 248 160 210 2321 410 150 350 2176 662 pmax of PH measuring loops HP optional material HP160 OD x WT 3 x 0 6 mm 0 12 x 0 024 in bar C psi F 106...

Страница 6: ...locity in measuring loops for best performance Selected sensors are only available in combination with temperature options T1 TA standard material and pressure range Serial single path versions offer the same accuracy at half the flow Qmax serial version 2 5 kg min No relevant pressure effect due to torsional oscillation and semi circle non deforming measurement section Uncertainty of reading incl...

Страница 7: ... cable length between RHM and RHE is 100m 330 ft 200m 660 ft only with factory approval Material of Wetted Parts 1 4539 SS 904 L UNS N08904 standard measuring loops material 1 4571 SS 316 Ti UNS S31635 standard connection part material optional measuring loops material 2 4602 Alloy C22 UNS N06022 Tantalum HP 160 Others on request Sensor Enclosure Housing Stainless Steel 1 4301 SS 304 optional in 1...

Страница 8: ...oops Seal Less Version pmax 213 bar PFT Parallel Measuring Loops Seal Less Version for Thread Connection pmax 530 bar SFT Serial Measuring Loops Seal Less Version for Thread Connection pmax 213 bar PH0 Parallel Measuring Loops with High Pressure Manifold and PTFE Seals pmax 540 bar SH0 Serial Measuring Loops with High Pressure Manifold and PTFE Seals pmax 540 bar PHH Parallel Measuring Loops with ...