GPS Grandmaster Clock
50
RT430-TM-EN-5
4. CONFIGURATION
4.1
Web Interface
RT430 has a Web Interface that allows configuring network parameters, time synchronism, output
synchronism and PTP standard, updating firmware, changing key, controlling access and manipulating
configurations.
To connect to the Web Interface, enter the unit E
THERNET
port IP address into the address field of a web
browser. For information on factory default settings of the E
THERNET
ports, see
Chapter 3
. If the unit is not
using factory default settings, see
Chapter 5
for instructions to obtain the current IP address.
A start page containing the unit status information opens once the Web Interface is accessed. The remaining
monitoring and configuring sections are on a menu on the left. To access them, click the desired menu item.
The configuring sections are:
Ethernet: allows configuring the network parameters.
Time Settings: allows configuring the time parameters.
Time Signals: allows configuring signals sent by synchronism outputs.
PTP: allows configuring synchronism parameters through PTP.
Setup: allows manipulating configurations, changing access control and key, and updating firmware.
Chapter 5
. describes firmware updates and key information.
The configuration sections should be edited one by one and at the end of each section, it is necessary to
transmit the changes made to the unit. Otherwise, the changes will not be saved. When transmitting changes
to the unit, username and password will be required. Factory default username and password are:
TABLE 32: Factory default username and password to configure.
User name
Configuratio
Passaword
1234