Specification Revised 10/07

220241

PT916BM/CM/WM 

GE Profile

 30" Built-In Single Convection Wall Oven

 

KW Rating

240V

4.5

208V

3.4

Breaker Size

240V

20 Amps

208V

20 Amps

Dimensions and Installation Information (in inches)

Most 30” Wall Cabinets can be used with this unit.
Note:

 

These ovens are not approved for 

stackable installations.

 Cabinets installed 

adjacent to wall ovens must have an adhesion 
spec of at least a 194°F temperature rating.
Door handle protrudes 3" from door face. Cabinets 
and drawers on adjacent 45° and 90° walls should 
be placed to avoid interference with the handle.

Electric wall ovens are not approved for 

installation with a plug and receptacle. They 

must be hard wired in accordance with  

installation instructions

Installation Information:

 Before installing, consult 

installation instructions packed with product for 
 current dimensional data.
Side-by-side installations rerquire at least 2" 
between cutouts.

CL

2 x 4 or

equivalent

runners

Suitable

bracing

to support

runners

21-5/8"

over centerline

of cabinet

(must support 275 lbs.)

Cutout width
28-1/2'' MIN.
28-5/8'' MAX.

29-3/4

C

30

Recommended 

cutout location 

32-1/2" 

from floor

21

Junction 

box

location

Allow minimum of 21'' for clearance

to adjacent corners, drawers, walls, or etc.
A=Allow 1" overlap of oven over top and bottom edges of cutout.

B=Allow 11/16"-3/4" for overlap of oven over side edges of cutout.

C=28-1/4" without trim and 28-3/4" with trim.

Conduit

(72" 

long)

5

27-1/4'' MIN.
27-5/16'' MAX.
Cutout height

A

B

23-1/2'' MIN.

Cutout depth

22'' MIN.

CL

2 x 4 or

equivalent

runners

Suitable

bracing

to support

runners

21-5/8"

over centerline

of cabinet

(must support 275 lbs.)

Cutout width
28-1/2'' MIN.
28-5/8'' MAX.

29-3/4

C

30

Recommended 

cutout location 

32-1/2" 

from floor

21

Junction 

box

location

Allow minimum of 21'' for clearance

to adjacent corners, drawers, walls, or etc.
A=Allow 1" overlap of oven over top and bottom edges of cutout.

B=Allow 11/16"-3/4" for overlap of oven over side edges of cutout.

C=28-1/4" without trim and 28-3/4" with trim.

Conduit

(72" 

long)

5

27-1/4'' MIN.
27-5/16'' MAX.
Cutout height

A

B

23-1/2'' MIN.

Cutout depth

22'' MIN.