background image

For answers to your Monogram,

® 

GE Profile

 or  

GE

®

 appliance questions, visit our website at 

ge.com or call GE Answer Center

®

 service, 

800.626.2000.

220595

Listed by 

Underwriters 

Laboratories

Note:

 Check local codes for required breaker size

Important:

 Requires a 5” free area between 

the bottom of the cooktop to any combustible 
material, i.e., shelving. Free area not required 
when installing wall oven underneath cooktop. 
Refer to installation instructions. Requires a  
15” minimum from cooktop to adjacent  
overhead cabinets. Units are furnished with  
a 48” flexible armored cable. 

Note:

 30” Ribbon cooktops are approved for use over select GE 30” Single 

Wall Ovens and Warming Drawers. All 30" ribbon cooktops can be installed 
over 27" wall ovens and warming drawers. Refer to cooktop and wall oven/
warming drawer installation instructions packed with product for current 
dimensional data. If installed with a GE Profile

™ 

Telescopic Downdraft System, 

consult both the cooktop and downdraft installation instructions packed 
with product before installing. Cooktop gas/electric supply may need to be 
re-routed to install downdraft. The countertop must be at least 26" deep with 
a flat surface area of 23-1/2" or more, front to back. In addition, other  
clearances to the front edge of the countertop must be considered.  
Consult cabinet and countertop manufacturer’s specs for flush mount  
installation prior to install. 

Before installing, consult installation  

instructions packed with product for current dimensional data.

 

KW Rating

240V

7.4

208V

5.6

Breaker Size

240V

40 Amps

208V

30 Amps

3-1/4*

Cooktop

2-1/2**

Required

28-1/2

19-5/8

29-7/8

30_ss_cktp_install.eps

21-1/2

Electrical junction box 16" MIN. 

below countertop

30" MIN. to

unprotected

cabinet

Cut should 

not interfere 

with cabinet

structure 

at front

1-1/2" MIN.

clearance to

side wall

from cut-out

1-1/2" MIN.

clearance to

side wall

from cut-out

1-3/4" to

rear wall

13" MAX.

depth

  * Depth of unit at conduit connection location (rear) is 

6-1/2" on models PP980/950 and 4-5/8" on models 

PHP900/PP975/972/962/945/942/932/912, 

JP655/356/346.

 **Raised bull nose countertops may require up to 

3/8" additional clearance to prevent interference 

with curved front.

15" MIN.  

to cabinet

PP950SM 

GE Profile

™ 

30" Built-In CleanDesign Electric Cooktop

 

Specification Revised 12/07

Dimensions and Installation Information (in inches)

Отзывы: