PP942SM
GE Profile
™
30" Built-In CleanDesign Electric Cooktop
220587
Listed by
Underwriters
Laboratories
†
Note:
Check local codes for required breaker size
Important:
Requires a 5” free area between
the bottom of the cooktop to any combustible
material, i.e., shelving. Free area not required
when installing wall oven underneath cooktop.
Refer to installation instructions. Requires a
15” minimum from cooktop to adjacent
overhead cabinets. Units are furnished with
a 48” flexible armored cable.
Note:
30” Ribbon cooktops are approved for use over select GE 30” Single
Wall Ovens and Warming Drawers. All 30" ribbon cooktops can be installed
over 27" wall ovens and warming drawers. Refer to cooktop and wall oven/
warming drawer installation instructions packed with product for current
dimensional data. If installed with a GE Profile
™
Telescopic Downdraft System,
consult both the cooktop and downdraft installation instructions packed
with product before installing. Cooktop gas/electric supply may need to be
re-routed to install downdraft. The countertop must be at least 26" deep with
a flat surface area of 23-1/2" or more, front to back. In addition, other
clearances to the front edge of the countertop must be considered.
Consult cabinet and countertop manufacturer’s specs for flush mount
installation prior to install.
Installation Information:
Before installing, consult installation instructions
packed with product for current dimensional data.
KW Rating
240V
7.8
208V
5.9
Breaker Size
240V
40 Amps
†
208V
30 Amps
†
3-1/4*
Cooktop
2-1/2**
Required
28-1/2
19-5/8
29-7/8
30_ss_cktp_install.eps
21-1/2
Electrical junction box 16" MIN.
below countertop
30" MIN. to
unprotected
cabinet
Cut should
not interfere
with cabinet
structure
at front
1-1/2" MIN.
clearance to
side wall
from cut-out
1-1/2" MIN.
clearance to
side wall
from cut-out
1-3/4" to
rear wall
13" MAX.
depth
* Depth of unit at conduit connection location (rear) is
6-1/2" on models PP980/950 and 4-5/8" on models
PHP900/PP975/972/962/945/942/932/912,
JP655/356/346.
**Raised bull nose countertops may require up to
3/8" additional clearance to prevent interference
with curved front.
15" MIN.
to cabinet
Specification Revised 12/07
Dimensions and Installation Information (in inches)