PP9036DJ 

GE Profile

 Series 36" Built-In Touch Control Cooktop

 

Specification Revised 6/16

To insure accuracy, it is best to make a

template when cutting the opening in the counter

Electrical junction box 

16" MIN.

below countertop

Cooktop

36"

20-3/8"

18-7/8"

33-3/4"

19-1/8"

 to

19-1/4"

33-7/8"

to 

34"

CP9536SJ, PP9036DJ,

PP7036DJ, JP5036DJ

2-1/2" MIN.

Required

1-3/4" MIN.

to rear wall

13" MAX.

 depth of unprotected

overhead cabinets (when no

hood or microwave is installed)

15" MIN.

 height from countertop

to nearest cabinet (including

light rails) on both sides of

cooktop

3-1/4"

 at front of unit and

5-9/16"

 at conduit location

30" MIN.

 from countertop to

unprotected cabinet (when

no hood or microwave is

installed)

2" MIN.

 clearance

to side wall from cut-out

on both sides of cooktop

See label next

to nameplate for

MIN. clearance

to wall

IMPORTANT: 

Requires a 5" free area between 

the bottom of the cooktop to any combustible 

material, i.e., shelving. Free area not required 

when installing wall oven underneath cooktop. 
Refer to installation instructions. Requires 

a 15" minimum from cooktop to adjacent 

overhead cabinets. Units are furnished with a 
48" flexible armored cable. 

NOTE: 

36" Ribbon cooktops are approved for 

use over select GE 30" Single Wall Ovens and 
Warming Drawers. Refer to cooktop and wall 
oven/warming drawer installation instructions 
packed with product for current dimensional 
data. If installed with a GE Telescopic 
Downdraft System, consult both the cooktop 
and downdraft installation instructions packed 
with product before installing. Cooktop gas/
electric supply may need to be re-routed to 
install downdraft. The countertop cutout 
requires 23-1/2" minimum flat countertop 
surface and 25" minimum total countertop 
depth. In addition, other clearances to front 
edge of the countertop must be considered.  

Before installing, consult installation 
instructions packed with product for   
current dimensional data. 

DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)

APPROXIMATE COOKING DIMENSIONS

Listed by 

Underwriters 

Laboratories

ADA

COMPLIANT

VOLTAGE (60HZ AC)

240V

208V

CONNECTED LOAD (MAX.)

9.6kW

7.2kW

CURRENT DRAW (MAX.)

40.0 Amps 34.7 Amps

RECOMMENDED CIRCUIT BREAKER

40 Amps

40 Amps

NOTE:

 

Check local codes for required breaker size.