background image

Specification Revised 9/04

220824

TM

JDP47BF/CF/WF – GE Profile

™ 

 30" Drop-In Electric Range

Dimensions (in inches)

KW Rating

240V

11.6

208V

8.7

Breaker Size

240V

40 Amps

208V

40 Amps

R

Listed by 

Underwriters 

Laboratories

For answers to your Monogram,

®

 GE Profile

 or 

GE appliance questions, visit our website at

GEAppliances.com or call 

GE Answer Center

®

 service, 800.626.2000.

Optional Kits For Drop-In Electric Ranges 

(Available At Additional Cost)

Note:

 Cabinets installed adjacent to drop-in electric ranges must have an 

adhesion spec of at least a 194°F temperature rating.

Note:

 All 30" Drop-In Radiant Ranges conform to U.L. requirements for 0" 

spacing from range to adjacent walls below countertop. To reduce possibility 

of scorching the side walls above the countertop when no load is present on 

burners, it is recommended that a minimum 6" spacing from adjacent side 

wall be allowed for possible extended high-heat element operation.

Installation Information:

 Before installing, consult installation instructions 

packed with  product for current dimensional data.

IMPORTANT:

30" DROP-IN RANGES ARE DESIGNED TO HANG 

FROM THE COUNTERTOP. IT DOES NOT REST ON THE FLOOR. 

FOR INSTALLATION ALTERNATIVES, REFER TO INSTALLATION 

INSTRUCTIONS PACKED WITH  PRODUCT.

Maintop Filler

(Fills gap between cooktop and 
wall when unit is installed in 
30" free-standing cutout)
JXS66WW—White
JXS66CC—Bisque
JXS66BB—Black

Accessory Backguards

(Attaches to the back of range as 
a backguard when unit is installed 
in 30" free-standing cutout)
JXS37WW—White
JXS37CC—Bisque
JXD37BB—Black/Stainless

Lower Trim Kits

(When a drop-in is installed in an 
existing cutout greater than 27-1/4" 
from the counter to the cabinet 
cross-rail, a lower trim kit should 
be used to fill the gap at the 
bottom of the range)
JXS96WW—White
JXS96CC—Bisque

Acceptable Electrical Outlet 

Area Also In Adjacent

Cabinet Or Under Floor

Conduit is 40" long

Shave Raised Edge To Clear

31-1/8" Wide Control Panel

9/16

30" Min.

30" Min.

15" Min.

6" Min.  

from walls

7-1/2

2-7/8"

To Front Surface  

of Countertop 

30

36

27-1/2

25

23-3/16

If necessary,  

build upsides  

to 1-1/4" thick  

to provide  

countertop 

support

2000_drop_in.eps

26-1/2

27

20-5/8" Door  

Clearance  

From Front  

Surface of  

Countertop

24

31-1/4

30

A/B

Accessory 

Backguard

Acceptable Electrical Outlet 

Area Also In Adjacent

Cabinet Or Under Floor

Conduit is 40" long

Shave Raised Edge To Clear

31-1/8" Wide Control Panel

9/16

30" Min.

30" Min.

15" Min.

6" Min.  

from walls

7-1/2

2-7/8"

To Front Surface  

of Countertop 

30

36

27-1/2

25

23-3/16

If necessary,  

build upsides  

to 1-1/4" thick  

to provide  

countertop 

support

2000_drop_in.eps

26-1/2

27

20-5/8" Door  

Clearance  

From Front  

Surface of  

Countertop

24

31-1/4

30

A/B

Accessory 

Backguard

an Anti-Tip device. The installation 

of this device is an important, 

required step in the installation 

of the range.

Отзывы: