Pro Elite™ Professional Series  

Water Treatment System by GE

Operation Manual  

Pro Elite Analyzer

Содержание Pro Elite 268-716-100-1044

Страница 1: ...Pro Elite Professional Series Water Treatment System by GE Operation Manual Pro Elite Analyzer ...

Страница 2: ... Cursors 17 Button Functions 17 Programming Overview 18 Analyzer Control Operation 18 Level I Programming 18 Level l Programming Analyzer Conditioner 19 Level II Programming P Values 20 Programming the Lockout Feature 20 Level lll Cycle Programming C Values 21 Level IV Viewing History H Values 22 Program Reset 22 Placing 268 Water Conditioning System Into Operation Fill Brine Tank Last 23 Placing ...

Страница 3: ...ed to minimize the amount of regenerant brine and water used in its operation Efficiency rated water softeners shall have a rated salt efficiency of not less that 3350 grains of total hardness exchanged per pound of salt based on NaCl equivalency 477 grams of total hardness exchanged per kilogram of salt and shall not deliver more salt than its listed rating The rated efficiency of the water softe...

Страница 4: ...ightened plumber tape may be used on connections that do not use an O ring seal Do not use pipe dope type sealants on the valve body Do not use pliers or pipe wrenches Do not use petroleum based lubricants such as Vaseline oils or hydrocarbon based lubricants Use only 100 silicone lubricants Use only the power transformer supplied with this water conditioning system All electrical connections must...

Страница 5: ... x 36 48 3 x 91 5 cm 19 x 36 48 3 x 91 5 cm Salt Storage 240 lbs 109 kg 240 lbs 109 kg 240 lbs 109 kg Drain Water Rate 2 7 gpm 10 2 L m 3 9 gpm 14 7 L m 3 9 gpm 14 7 L m Service Connection Size 1 NPT 1 NPT 1 NPT Drain Connection Size 3 4 NPT 3 4 NPT 3 4 NPT Recharge Brine Connection Size 3 8 NPT 3 8 NPT 3 8 NPT Installation Space Requirements 21 x 42 x 72 53 3 x 106 6 x 182 8 cm 21 x 42 x 72 53 3 ...

Страница 6: ...e conditioner be installed in a protected environment When installing the water conditioning system outdoors several items must be considered Moisture The valve and control are rated for NEMA 3 locations Falling water should not affect performance The system is not designed to withstand extreme humidity or water spray from below Examples are constant heavy mist near corrosive environment or upward...

Страница 7: ...anism 3 Jacket Resin Tank 11 Tank Collar 4 Base 12 Riser Tube 5 268 Logix PE Valve w 716 Control 13 Upper Basket 6 Resin Tank 14 Cover 7 Door Access Sensor 15 Shield 8 Sensors Wired Probes Brine Tank 1 2 3 4 5 6 7 1 Cover 5 Brine Tube Assembly 2 Collar Tank 6 Foot Leveling 3 Tank Brine 7 Latch Mechanism 4 Base Tank ...

Страница 8: ...8 Equipment Installation Dimensions 36 9 938 1 60 7 1541 6 28 2 715 9 32 2 817 5 53 4 1356 6 55 1398 1 5 0 127 2 5 63 5 ...

Страница 9: ...n Floor Drain Figure 1 Standard Basement Before Installation Cold water lines shown Soft Water Hard Water Outside Faucet Outside Faucet Bath Tub Lavatory Toilet Kitchen Laundry Tubs Pump or Meter Hot Water Outlet Water Heater Brine Tank Overflow Drain Floor Drain Drain Line Bypass Softener Grounding Strap Figure 2 Softened Water Flow Diagram ...

Страница 10: ...ay the cover aside for now To Assemble the Media Tank 1 If the floor under the media tank is uneven the leveling feet may be installed Slowly lay the tank on its side Press or tap the feet into the pockets WARNING The media tank contains loose particles that will shift If the tank is turned upside down or laid back quickly the particles may enter the valve If this happens the valve may need to be ...

Страница 11: ... B Y P A S S B Y P A S S Water Conditioner Water Conditioner In Out In Out Figure 7 Model 1265 Bypass Included Water Conditioner Water Conditioner Water Conditioner Water Conditioner Normal Operation In Bypass Figure 8 Typical Three Valve Bypass Configuration Not provided by manufacturer WARNING Do not use tools to tighten plastic fittings Over time stress may break the connections Hand tighten th...

Страница 12: ... drain line connection This will provide an adequate siphon trap Tie or wire the hose in place at the drain point Also provide an air gap of at least 1 1 2 inch between the end of the hose and the drain point 5 When the drain empties into an overhead sewer line a sink type trap must be used 6 Secure the end of the drain line to prevent it from moving Figure 9 Drain Line Connection WARNING Never in...

Страница 13: ...cure hose in place Drain Air Gap Figure 12 Electrical Connection Note There are no user serviceable parts in the AC adapter motor or the control board The Analyzer control operates on a 12 volt alternating current power supply This requires use of the Pentair Water supplied AC adapter AC adapters are available from your supplier for different applications They include AC Adapter Input Voltage Appl...

Страница 14: ...generant draw is completed when the air check closes Slow Rinse Downflow Cycle C3 Water flow moves the regenerant through the resin at a specific rate and rinses to the drain The resin is regenerated Repressurization Cycle C4 Pressure is balanced in the valve before continuing the regeneration Fast Rinse Downflow Cycle C5 Water passes through the resin bed and up through the riser to drain All rem...

Страница 15: ... optical sensor which is rotated approximately 90 degrees out of phase Note If electrical power is not available the camshaft can be rotated counterclockwise by hand if the motor is removed Cycle Indicators 0 Treated Water or brine make up if recharge cycle has started 1 Backwash Cycle 2 Regenerant Draw Cycle 3 Slow Rinse Cycle 4 System Pause 5 Fast Rinse Cycle 1 6 2nd Backwash 7 2nd Fast Rinse 8 ...

Страница 16: ...used such as those sold for commercial laundries adjust the dosage accordingly 1 Dosage Polystyrene resin 1 2 fluid ounce 35 5 mL per cubic foot Non resinous exchangers 0 8 fluid ounce 23 7 mL per cubic foot 2 Regenerant tank conditioners A Backwash the conditioner and add the required amount of hypochlorite solution to the well of the regenerant tank The regenerant tank should have water in it to...

Страница 17: ... as a solid icon during regeneration 12 When hourglass is flashing this indicates that the control is moving to a regeneration cycle Appears as a solid icon during a cancelled regeneration and the control is cycling directly back to the home position 13 Indicates the selected program setting has been locked out Lock settings are changed in Level II programming 14 Indicates double regeneration 15 N...

Страница 18: ...nformation in memory for 8 to 24 hours depending on the installation If the super capacitor is exhausted the Analyzer control will display four dashes immediately upon power up The Time of Day and Day of Week must be reset All other programmed parameters are stored in the static memory and are retained during power outages Level I Programming The Analyzer control can be quickly programmed by follo...

Страница 19: ...press then or press press then PM Cubic feet 1 0 to 2 0 Lbs ft 3 Time Day Regeneration Time Day Time Day Regeneration Time Day Time Day Regeneration Time Day Time Day Regeneration Time Day Time Day Regeneration Time Day Time Day Regeneration Time Day Time Day Regeneration Time Day Salt Amount SU MO TU WE TH FR SA DAYS Capacity KG press Time Day Regeneration Time Day Programming is complete Estimat...

Страница 20: ...alt Setting 3 18 50 290 1 10 9 110 Lbs Cu ft3 g L Set in Level I Programming P7 Capacity View Only 1 140 0 1 14 0 1 0 1 Calculated Kilograins Kilograms Values dependent on P9 setting P8 Not Used P9 Units of Measure 0 1 1 0 0 US 1 Metric P10 Clock Mode 0 1 1 0 0 12 Hr 1 24 Hr P11 Service Interval 0 99 1 0 Months 0 Disabled 30 Day Month P12 Minimum Days Between Regeneration 0 14 1 0 Days P13 Low Sal...

Страница 21: ... Flow rate dictated by size of drain line flow controller C2 Regenerant Draw Not Adjustable 1 Min See Notes Automatically calculated from resin volume and salt dosage settings C3 Slow Rinse 0 200 1 Min See Notes Automatically calculated from resin volume and salt dosage settings C4 Repressurization 0 200 1 Min 3 Allows system to equalize water pressure across valve discs C5 Fast Rinse 0 200 1 Min ...

Страница 22: ...wn for three seconds while H4 number of regenerations since last reset is being displayed will reset the numbers stored in H4 H5 H6 H7 and H8 Holding the set key down for three seconds while H9 months since last serviced is being displayed will reset the numbers stored in H4 H5 H6 H7 H8 and H9 Program Reset The Analyzer control can be reset to original factory parameters when viewing the H0 parame...

Страница 23: ...trol reaches the backwash cycle the hourglass is no longer displayed and the motor will turn off Pressing the SET button will display the time remaining for the current cycle 4 Fill the media tank with water A While the Analyzer control is in cycle Backwash open the water supply valve very slowly to approximately the 1 4 open position Water will begin to enter the media tank Air will begin to be p...

Страница 24: ...th the control in the treated water position press and hold the REGEN button on the control for five seconds This will initiate a manual regeneration The control will display an hourglass indicating that the motor and camshaft are turning The control also displays the total regeneration time remaining When the control reaches the pre pressurize cycle the hourglass is no longer displayed and the mo...

Страница 25: ...ther regeneration Advance the controller to the brine refill position C8 to prime the line between the regenerant tank and the valve conditioner only A Slowly open the main water supply valve again to the fully open position Be sure not to open too rapidly as that would push the media out of the media tank Note As you advance through each cycle there will be a slight delay before you can advance t...

Страница 26: ... immediate manual regeneration A solid regeneration icon will be displayed The control will immediately begin a regeneration Delayed Second Regeneration Pressing and releasing the REGEN button while the control is in regeneration will program the control for a delayed second regeneration A flashing x2 icon next to the regeneration icon will appear indicating a second regeneration will start when t...

Страница 27: ...27 Pro Elite Valve Exploded View and Parts List BYPASS BYPASS 20 21 22 23 24 1 2 3 4 5 6 7 8 9 10 12 13 14 15 16 17 18 19 11 12 ...

Страница 28: ... 18 1010154 O Ring Tank 1 4000585 Skirt Pro Elite Lt Gray 1 19 1232370 O Ring Riser Tube 1 8 1000811 Transformer 120 VAC 60 Hz N American Plug 1 20 4001033 Probe Cable Clips Kit 1 9 3019221 Motor Optical Cable 1 1041174 Valve Disc Kit 1 10 1000226 Screen Cap Assembly w O Ring 1 21 1040930 1265 Bypass Valve 1 11 Drain Control Assembly 1 22 Drain Line Flow Control Options 1 1000212 No 10 2 7 gpm 10 ...

Страница 29: ...29 19 21 22 23 24 25 2 3 4 5 6 7 9 10 12 13 14 15 16 17 18 11 Conditioner Tank and Regenerant Tank Assembly Exploded View and Parts List 1 A A A 26 20 8 27 28 5 26 29 ...

Страница 30: ...utton GE Logo 1 4 1 26 1234170 Screw 8 18 x 9 16 Type 25 4 10 4000347 Cover Brine Tank Pro Elite 1 27 4001265 Washer Countersunk Finishing SS 4 11 4000348 Collar Brine Tank Pro Elite 1 28 4001266 Screw Flat HD Phil SS 4 12 4000349 Tank Brine Pro Elite 1 28 4001033 Kit Logix Sensor 1 13 4000350 Base Brine Tank Pro Elite 1 4000871 Valve Brine Connection Fitting Female Elbow 3 8 NPT x 3 8 NPT 14 4000...

Страница 31: ... CH15024 Cap Brine Well 4 Dia Caplug STP 4 1 6 60068 8 06 Brine Float w One Grommet As Purchased 1 7 60002 27 Air Check Assembly 1 8 BR10332 Tubing Insert Brass 2 CH20774 Overflow Fitting Assembly 1 CH15031 1 Overflow Elbow 1 CH15031 2 Overflow Nut 1 CH16331 Gasket 1 CH20731 1 Polypro Washer 1 Items includetd but not shown Shipped in a plastic bag along with Brine Well Assembly 1 2 3 4 5 6 7 8 8 C...

Страница 32: ...tical sensor is connected and in place Verify that motor gear has engaged cam gear If everything is connected try replacing in this order 1 Wire harness motor optical sensor assembly 2 Control Camshaft is turning more than five minutes to find Home position Verify that optical sensor is in place and connected to wire Verify that camshaft is connected appropriately Verify that no dirt or rubbish is...

Страница 33: ...ding to instructions b Remove restriction c Clean injector and screen d Replace injector and cap Contact dealer e Remove foreign matter from disc and check disc for closing by pushing in on stem Replace if needed Contact dealer f Put control momentarily into brine refill Replace or repair air check if needed Contact dealer Control will not regenerate automatically a AC adapter or motor not connect...

Страница 34: ...Pentair Residential Filtration LLC 5730 North Glen Park Road Milwaukee WI 53209 4454 USA 262 238 4400 Phone 262 238 4402 Fax 2011 Pentair Residential Filtration LLC P N 4001051 Rev D MR14 ...