PrecisionLine  RCR-90

PrecisionLine

 

 

 

 

 

RCR-90

Dual Technology Motion Sensor

Installation Instructions

Description

The RCR-90 combines range-controlled radar (RCR) technology
with a passive infrared (PIR) system to increase false alarm
immunity by allowing it to sense human-sized objects within a
specified range. Both the RCR and PIR systems must be triggered
to set off an alarm, unless in

 

radar-only mode.

The detector is designed to use a 12VDC power supply provided
by a UL Listed alarm control panel.

Features

 

The detector provides the following features:

High-security (radar-only) mode - Internal jumper allows you
to disable the PIR, and use the radar-only mode to detect
intruders faster. This mode can be used for covert installations
(mounted behind ceiling panels or walls).

Selectable range up to 90 feet (27.4m) - Internal jumper
allows radar range selection to optimize coverage.

LED indicator - A multi-color LED provides detector status.

Tamper switch - Activated when the pins on the circuit board
are removed from the terminal sockets on the base.

Selecting a Location for the
Detector

The detector can be mounted in a corner or on a flat wall. Use the
following guidelines to determine the best location to install the
detector:

Mount the detector so the expected movement of an intruder is
across the detection pattern. See Figure 2.

Mount the detector on a stable surface 8 to 12 feet (2.4 to 3.7m)
high.

DO NOT mount the detector within 2 feet (0.6m) of  metallic
objects or within 5 feet (1.5m) of florescent lights.

DO NOT place objects in front of the detector that may prevent
a clear line of sight. (Not applicable in radar-only mode.)

Avoid locations that expose the detector to possible false alarm
sources such as:

– Moving or vibrating objects (fans, pulleys, conveyor belts)

– Electronic fields (electric motors, high voltage equipment)

– Water spray or corrosive environments

– Heat sources in the field of view (heaters, radiators)

– Windows in the field of view

– Strong air drafts on the detector (fans, air conditioners)

When installing multiple detectors:

– DO NOT mount detectors facing each other.

– Mount detectors at least 20 feet (6.1m) apart.

– Use shorter range settings to avoid overlapping radar coverage.

Figure 2.  Coverage Pattern

Figure 1.  Detector (Exploded)

Base

Front cover/electronic module

Bracket

Closing screw

10’
(3m)

10’
(3m)

35’
(11m)

50’
(15m)

90’
(27m)

80’(24m)

90’(27m)

70’(12m)

50’(15m)

50’(15m)

90’(27m)

80’(24m)

70’(12m)

60’(18m)

60’(18m)

Preliminary
August 7, 2003

Содержание PrecisionLine RCR-90

Страница 1: ...in a corner or on a flat wall Use the following guidelines to determine the best location to install the detector Mount the detector so the expected movement of an intruder is across the detection pattern See Figure 2 Mount the detector on a stable surface 8 to 12 feet 2 4 to 3 7m high DO NOT mount the detector within 2 feet 0 6m of metallic objects or within 5 feet 1 5m of florescent lights DO NO...

Страница 2: ...g screw See Figure 1 10 Apply power The green LED should light for approximately 25 seconds and then go out 11 Walk test the coverage pattern as follows Walk throughout the intended coverage area Verify the detector alarms See Understanding the LED Note Most units walk test more accurately if the person testing waits 10 seconds between tripping the unit and walking again This allows the detector t...

Страница 3: ...verage area may cause false alarms J3 LED ON LED enabled factory default OFF LED disabled J4 PIR ON Radar only enabled OFF PIR and Radar enabled factory default Understanding the LED The multi color LED located on the bottom of the detector indicates the status of the unit as described in the following table In Radar only mode LED Status Red PIR and Radar detection The detector is in alarm and the...

Страница 4: ... relay stealth mode tamper contacts 90 foot 27 4m maximum range www GE Interlogix com 2003 GE Interlogix 12345 SW Leveton Drive Tualatin OR 97062 Phone 503 692 4052 USA Canada 800 547 2556 Technical Service 800 648 7424 FaxBack 800 483 2495 GE Interlogix Maintaining the Detector When installed and used properly the detector provides many years of service with minimal maintenance You should walk te...

Отзывы: