11-3
TABLE 11-3
GENERAL CABINET SPECIFICATIONS
NOTE:
All specifications do not include measurement instumentation accuracy.
3-2General Input Power Specifications
TABLE 11-4
MODEL DEPENDENT SPECIFICATIONS
Dimensions
Generator Cabinet
Height: 1600
mm
Width: 550
mm
Depth: 450
mm
Weight: 150kg
PARAMETER JEDI
GENERATOR
Input Voltage
380/400/415/440/460/480VAC three phase and Ground without neutral
Daily Voltage Variations
+/– 10% (in this range, the generator shall operate without any derating in accuracy)
Line Impedance Specification
IEC Specification
Line Impedance
The apparent line impedance guaranteed by the customer should be equal or less
than the values indicated below, according to the voltage value and the commercial
power of the generator.
Voltage range (V)
line impedance (Ohms)
3 (phase)
65kW
80 kW
380 0.12
0.09
415 0.14
0.11
440 0.15
0.125
480 0.18
0.15
HV cable type
IB EEC: 22mm cable de Lyon (<=150pF/m)
USA: 22mm DSI (<=165pF/m)
EEC: 16mm Claymount (<=165pF/m)
HV cable connector=Federal standard
Ground Wire
Same as power cable
Inrush Current
600A
Normal Frequency
50/60Hz
Daily Frequency Variation
+/–6%