Table 5-2: Analog Output Options
Setting
Description
Available Options
Output A Parameter
Choose which parameter will be
output on analog channel A.
Humidity, Temperature, Pressure or
User Equation
Output A Units
Choose the units for scaling this
parameter.
See Table 4-1 on page 4-4 for the
parameter chosen.
Output A Upper
Set the parameter value that will
produce full-scale output.
Enter a number.
Output A Lower
Set the parameter value that will
produce zero output.
Enter a number.
Output B Parameter
Choose which parameter will be
output on analog channel A.
Humidity, Temperature, Pressure or
User Equation
Output B Units
Choose the units for scaling this
parameter.
See Table 4-1 on page 4-4 for the
parameter chosen.
Output B Upper
Set the parameter value that will
produce full-scale output.
Enter a number.
Output B Lower
Set the parameter value that will
produce zero output.
Enter a number.
Table 5-3: Communication Parameter Options
Setting
Description
Available Options
Serial Mode
Set whether data is transmitted
continuously or on demand.
All, Query (see Query Mode Format on
page 4-17)
Baud
Set the baud rate to be compatible
with the receiving device.
300, 1200, 2400, 4800, 9600, 19200,
38400, 57600
Parity
Set the parity as required by the
receiving device.
None, Odd, Even, Mark or Space
Number of Data Bits
Set the number of data bits as
required by the receiving device.
7 or 8
Number of Stop Bits
Set the number of stop bits as required
by the receiving device.
1, 1.5 or 2
Serial Flow Control
Set the flow control as required by the
receiving device.
None, Software, Hardware
Содержание Optica
Страница 1: ...GE Sensing Optica General Eastern Dew Point Analyzer Operator s Manual ...
Страница 11: ...Chapter 1 ...
Страница 20: ...Chapter 2 ...
Страница 43: ...Chapter 3 ...
Страница 58: ...Chapter 4 ...
Страница 80: ...Chapter 5 ...
Страница 81: ...Programming the 4x40 Optica Introduction 5 1 Programming Technique 5 2 Programmable Functions 5 4 ...
Страница 94: ...Chapter 6 ...
Страница 95: ...Network Based Programming Introduction 6 1 Programming Screens 6 1 ...
Страница 99: ...Chapter 7 ...
Страница 109: ...Appendix A ...
Страница 114: ...Appendix B ...
Страница 115: ...Humidity Equations and Conversion Chart Introduction B 1 Vapor Pressure B 1 Humidity B 2 ...
Страница 118: ...Humidity Equations and Conversion Chart B 3 January 2006 Figure B 1 Graphical Humidity Conversion Chart ...
Страница 119: ...Appendix C ...
Страница 120: ...Configuring the Serial Interface Wiring to a Personal Computer C 1 ...
Страница 122: ...Appendix D ...
Страница 123: ...Chilled Mirror Sensors Introduction D 1 Depression D 1 Measurement Range D 2 Comparing Optica Models D 3 ...
Страница 127: ...Appendix E ...
Страница 128: ...Glossary ...
Страница 130: ...Appendix F ...
Страница 133: ...Appendix G ...
Страница 134: ...Communicating with the OPTICA Using Ethernet Direct Communication G 1 Computer Communication G 1 ...