69 SBC622 Hardware Reference Manual
A.1.1 Backplane P0/J0 Connector
VPX
P0/J0
connects
to
power
management.
P0
Table A-1 Power Management (P0)
J0
Table A-2 Power Management (J0)
NOTE
Per VITA 46 specification for 6U boards, VS1=12V and VS3=5V nominal.
P1 Pin
Row G
Row F
Row E
Row D
Row C
Row B
Row A
1
Vs1
Vs1
Vs1
NC
NC
NC
NC
2
Vs1
Vs1
Vs1
NC
NC
NC
NC
3
Vs3
Vs3
Vs3
NC
Vs3
Vs3
Vs3
4
NC
NC
GND
-12V Aux
GND
SYSRESET#
NVMRO
5
NC
GA4#
GND
3v3 Aux
GND
SMB_CLK
SMB_DAT
6
GA3#
GA2#
GND
+12V Aux
GND
GA1#
GA0#
7
TCK
GND
TDO
TDI
GND
TMS
TRST#
8
GND
NC
NC
GND
NC
NC
GND
J1 Pin
Row I
Row H
Row G
Row F
Row E
Row D
Row C
RowB
Row A
1
Vs1
Vs1
Vs1
Vs1
NC
NC
NC
NC
NC
2
Vs1
Vs1
Vs1
Vs1
NC
NC
NC
NC
NC
3
Vs3
Vs3
Vs3
Vs3
NC
Vs3
Vs3
Vs3
Vs3
4
GND
NC
NC
GND
-12V Aux
GND
SYSRESET#
NVMRO
GND
5
GND
NC
GA4#
GND
3v3 Aux
GND
SMB_CLK
SMB_DAT
GND
6
GND
GA3#
GA2#
GND
+12V Aux
GND
GA1#
GA0#
GND
7
TCK
GND
GND
TDO
TDI
GND
GND
TMS
TRST#
8
NC
GND
NC
NC
GND
NC
NC
GND
NC
Содержание OpenVPX VPXcel6 SBC622
Страница 2: ...Document History Hardware Reference Document Number 500 9300527818 000 Rev B March 18 2011 ...
Страница 30: ...30 SBC622 Hardware Reference Manual Figure 1 2 SBC622 in Chassis VPX Backplane SBC622 inserted into Chassis ...
Страница 33: ...Installation and Setup 33 Figure 1 3 PMC Installed onto 2 PMC Site Model F ...
Страница 37: ...Installation and Setup 37 Figure 1 5 Front Panel SBC622 Isometric View Convection cooled F F ...