8-4
W650 Wind Generator Protection System
GEK-113032A
8.4 OBJECT DICTIONARY
8 W650 CANOPEN PROFILE
8
8.4OBJECT DICTIONARY
8.4.1 STANDARD OBJECTS
Index
Object
Sub-Index
Name
Type
Attr
Default
1000h
VAR
0
Device Type
UNSIGNED32
RO
00000000h
1001h VAR
0
Error
Register
UNSIGNED8
RO
0
1002h
VAR
0
Manufacturer Status Register
UNSIGNED32
RO
0
1003h
ARRAY
Predefined Error Field
ARRAY
0
Number Of Errors
UNSIGNED8
RW
0
1
Standard Error Field
UNSIGNED32
RO
0
...
Standard Error Field
UNSIGNED32
RO
0
254
Standard Error Field
UNSIGNED32
RO
0
1005h
VAR
0
COB-ID SYNC
UNSIGNED32
RW
00000080h
1006h
VAR
0
Communication Cycle Period
UNSIGNED32
RW
0
1008h
VAR
0
Manufacturer Device Name
VIS-STRING
CONST
“W650”
1009h
VAR
0
Manufacturer Hardware Version VIS-STRING
CONST
100Ah
VAR
0
Manufacturer Software Version
VIS-STRING
CONST
100Ch
VAR
0
Guard Time
UNSIGNED16
RW
0
100Dh
VAR
0
Life Time Factor
UNSIGNED8
RW
0
1014h
VAR
0
COB-ID Emergency Object
UNSIGNED32
RW
000 Node-ID
1015h
VAR
0
Inhibit Time EMCY
UNSIGNED16
RW
0
1016h
ARRAY
Consumer Heartbeat Time
ARRAY
0
Number of Entries
UNSIGNED8
RO
1
1
Consumer Heartbeat Time
UNSIGNED32
RW
0
1017h
VAR
0
Producer Heartbeat Time
UNSIGNED16
RW
400 ms
1018h
RECORD
Identity Object
RECORD
0
Number of Entries
UNSIGNED8
RO
1
1
Vendor ID
UNSIGNED32
RO
00000180h
Server SDO Parameter
1200h
RECORD
1
st
Server SDO Parameter
SDO
Parameter
0
Number Of Entries
UNSIGNED8
RO
2
1
COB-ID Client->Server (rx)
UNSIGNED32
RO
000 Node-ID
2
COB-ID Server->Client (tx)
UNSIGNED32
RO
000 Node-ID
Receive PDO Communication Parameter
1400h
RECORD
1
st
Receive PDO Parameter
PDO CommPar
0
Largest Sub-Index Supported
UNSIGNED8
RO
5
1
COB-ID Used By PDO
UNSIGNED32
RW
800 Node-ID
2
Transmission Type
UNSIGNED8
RW
254
3
Inhibit Time
UNSIGNED16
RW
0
4
RESERVED
UNSIGNED8
RW
0
5
Event Timer
UNSIGNED16
RW
0
1401h
RECORD
2
nd
Receive PDO Parameter
PDO CommPar
0
Largest Sub-Index Supported
UNSIGNED8
RO
5
1
COB-ID Used By PDO
UNSIGNED32
RW
800 Node-ID
2
Transmission Type
UNSIGNED8
RW
254
Содержание Multilin W650
Страница 2: ......
Страница 10: ...VIII W650 Wind Generator Protection System GEK 113032A TABLE OF CONTENTS ...
Страница 30: ...1 20 W650 Wind Generator Protection System GEK 113032A 1 4 W650 HARDWARE 1 GETTING STARTED 1 ...
Страница 140: ...4 72 W650 Wind Generator Protection System GEK 113032A 4 3 WEB SERVER 4 HUMAN INTERFACES 4 ...
Страница 360: ...7 48 W650 Wind Generator Protection System GEK 113032A 7 2 IEC 61850 PROFILE FOR W650 7 IEC 61850 PROTOCOL 7 ...
Страница 368: ...8 8 W650 Wind Generator Protection System GEK 113032A 8 4 OBJECT DICTIONARY 8 W650 CANOPEN PROFILE 8 ...
Страница 406: ...11 22 W650 Wind Generator Protection System GEK 113032A 11 15 RECLOSER 79 11 COMMISSIONING 11 ...
Страница 422: ...13 6 W650 Wind Generator Protection System GEK 113032A 13 4 RELAY CONFIGURATION 13 FREQUENTLY ASKED QUESTIONS 13 ...
Страница 446: ...A 22 W650 Wind Generator Protection System GEK 113032A A 1 LOGIC OPERANDS APPENDIXA A ...
Страница 596: ...D 8 W650 Wind Generator Protection System GEK 113032A D 5 IEC 60870 5 104 POINT LIST APPENDIXD D ...
Страница 622: ...F 2 W650 Wind Generator Protection System GEK 113032A F 1 GE MULTILIN WARRANTY APPENDIXF F ...