Installation Preparation

5

ADVANCE PLANNING

Ductwork Planning

• Determine the exact location of the vent hood.
• Plan the route for venting exhaust to the outdoors.
• Use the shortest and straightest duct route possible. 

For satisfactory performance, duct run should  
not exceed 100 equivalent length for any duct  
configurations.

• Refer to “Duct Fittings” chart to compute  

the maximum permissible length for duct runs  
to the outdoors.

CAUTION: 

To reduce risk of fire and to 

properly exhaust air, be sure to duct air outside–Do not 

vent exhaust air into spaces within walls or ceilings  

or into attics, crawl spaces or garages.

PRUDENCE

 – Il faut prendre soin 

d’installer un conduit vers l’extérieur pour réduire le 

risque d’incendie et pouvoir évacuer l’air correctement. 

Il ne faut pas évacuer l’air dans l’espace entre les parois 

d’un mur, un plafond ou un grenier, un espace sanitaire 

ou un garage.

POWER SUPPLY

IMPORTANT – (Please read carefully)

WARNING:

 

FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE 
PROPERLY GROUNDED.

AVERTISSEMENT

POUR DES RAISONS DE SÉCURITÉ, CET APPAREIL 
DOIT ÊTRE CORRECTEMENT MIS À LA TERRE.

Remove house fuse or open circuit breaker before  
beginning installation.

Do not use an extension cord or adapter plug with this 
appliance. Follow National Electrical Code or prevailing 
local codes and ordinances. 

Electrical supply

This vent hood must be supplied with 120V, 60Hz, and 
connected to an individual, properly grounded branch 
circuit, and protected by a 15 or 20 amp circuit breaker 
or time delay fuse.
• Wiring must be 2 wire with ground.
• If the electrical supply does not meet the above  

requirements, call a licensed electrician before  
proceeding.

• Use metal ductwork. These hoods must use 8" round 

duct. It can transition to 3-1/4" x 12", reducing the 
maximum equivalent duct length to 75 feet.

• Install a wall cap with damper or roof cap at the  

exterior opening. Order the wall or roof cap  
and any transition needed in advance. 

Wall Framing for Adequate Support

• This vent hood is heavy. Adequate structural support 

must be provided. The hood must be secured to  
vertical studs in the wall, or to a horizontal support. 
See page 9. 

• We strongly recommend that the vent hood with duct 

cover be on site before final framing and wall  
finishing. This will also help to accurately locate  
the ductwork and electrical service.

• Route house wiring as close to the installation location 

as possible in the ceiling or soffit. Wiring should enter 
at least 4" above the bracket on the right side.

• Connect the wiring to the house wiring in accordance 

with local codes.

Grounding instructions

The grounding conductor must be connected  
to a ground metal, permanent wiring system, or an 
equipment-grounding terminal or lead on the hood.

WARNING:

 The improper connection of 

the equipment-grounding conductor can result in a risk 
of electric shock. Check with a qualified electrician or 
service representative if you are in doubt whether the 
appliance is properly grounded.

AVERTISSEMENT

Le mauvais branchement du fil de mise à la terre peut 
causer un choc électrique. En cas de doute, consulter un 
électricien qualifié ou un technicien pour déterminer si 
l’appareil est à la terre.

Содержание Monogram ZV950

Страница 1: ...If you have questions call 800 GE CARES or visit our website at www monogram com Installation Instructions ZV950 36 Stainless Steel Vent Hood 124 Cover Art ...

Страница 2: ...n CAUTION To reduce risk of fire and to properly exhaust air be sure to duct air outside Do not vent exhaust air into spaces within walls or ceilings or into attics crawl spaces or garages PRUDENCE Il faut prendre soin d installer un conduit vers l extérieur pour réduire le risque d incendie et pouvoir évacuer l air correctement Il ne faut pas évacuer l air dans l espace entre les parois d un mur ...

Страница 3: ... 35 5 8 124Dia1 25 The supplied duct cover fits 8 ft to 10 ft ceilings The vent hood must be installed 24 min and 30 max above the cooking surface The hood installation height from the cooking surface to the bottom of the hood depends upon ceiling height Installation Height Depending on Ceiling Height 36 Min Cooking surface to bottom of hood should be 25 1 2 max for 8 ft ceiling height 25 1 2 to 3...

Страница 4: ... 2 to 27 1 2 25 1 2 to 28 1 2 25 1 2 to 29 1 2 25 1 2 to 30 25 1 2 to 30 25 1 2 to 30 25 1 2 to 30 25 1 2 to 30 25 1 2 to 30 25 1 2 to 30 25 1 2 to 30 26 1 2 to 30 26 1 2 to 30 26 1 2 to 30 26 1 2 to 30 26 1 2 to 30 30 min 30 min 30 min 30 min 30 min 30 min 30 min Duct Cover ZX14SDSS SUPPLIED OPTIONAL ACCESSORIES ZX14SDSS optional stainless steel duct cover is available for ceiling heights greater...

Страница 5: ...rcuit breaker or time delay fuse Wiring must be 2 wire with ground If the electrical supply does not meet the above requirements call a licensed electrician before proceeding Use metal ductwork These hoods must use 8 round duct It can transition to 3 1 4 x 12 reducing the maximum equivalent duct length to 75 feet Install a wall cap with damper or roof cap at the exterior opening Order the wall or ...

Страница 6: ...lexible ducting If flexible metal ducting is used all the equivalent feet values in the table should be doubled The flexible metal duct should be straight and smooth and extended as much as possible Do NOT use flexible plastic ducting Total Duct Run Note Any home ventilation system such as a ventilation hood may interrupt the proper flow of combustion air and exhaust required by fireplaces gas fur...

Страница 7: ...VE THE PACKAGING The vent hood is shipped secured to a shipping board with a shipping bracket and 4 screws Remove the duct cover parts box and other packaging Lift the hood out of the box Remove and properly discard the plastic wrapping Locate and remove 2 screws at the top of the hood Remove 2 screws at the bottom behind the filter guides on the left and right sides Remove the shipping bracket fr...

Страница 8: ... 2 piece Decorative Duct Cover dimension shown for reference only Tape the template in position along the penciled line CHECK TO BE SURE THE TEMPLATE IS LEVEL Ceiling ducting If ductwork will vent straight up to the ceiling Use a level to draw a line straight up from the centerline on the template to the ceiling Measure 6 1 4 from the back wall to the centerline of a 8 1 2 hole on the ceiling Note...

Страница 9: ...for Ductwork 124Dia25 View From Rear Cleats 1 x 6 Min Mounting Support 2 INSTALL MOUNTING BRACKETS This vent hood must be secured to the horizontal support or wall studs With the template taped in place use a punch to mark all mounting screw locations Drill 1 8 pilot holes at the 6 punched locations Remove the template The 4 support bracket holes must enter studs or the horizontal support Note Scr...

Страница 10: ...mounting brackets Tighten lower mounting screws Tighten screws B located at the top of the mounting bracket against the hood to clamp the position Do not overtighten screws 3 INSTALL DUCT BRACKET The duct bracket must be installed against the ceiling This bracket will hold the decorative duct cover in place at the top Install the 2 small screws into the sides of the duct bracket Remove the screws ...

Страница 11: ...nd wire a ground must be provided by the installer When house wiring is aluminum be sure to use U L approved anti oxidant compound and aluminum to copper connectors AVERTISSEMENT Si la maison n est pas câblée avec deux fils et un fil de terre l installateur doit installer un fil de terre Quand les fils sont en aluminium il faut prendre soin d utiliser des connecteurs aluminium à cuivre avec une pâ...

Страница 12: ... film covering the control panel on the front face of the hood and any other packaging materials Refer to the Owner s Manual for operating instructions Note While performing installations described in this book safety glasses or goggles should be worn For MonogramTM local service in your area call 1 800 444 1845 Note Product improvement is a continuing endeavor at General Electric Therefore materi...