– 9 –
4. Loosen the 2 wire retaining screws and
remove the wires from the surface light
socket.
Screw
Screw
Clamp
Clamp
Socket
Trim Ring
Trim Ring
Surface Lights
Removal and Replacement
WARNING:
Surface lights may be hot.
The surface lights are 120 volt, 50 watt, par-16
halogen flood bulbs. Part No. WB08X10028.
1. Turn the trim ring counterclockwise until it falls
from the socket.
2. Remove the light from the socket.
Surface Light Sockets
Removal and Replacement
1. Remove the
Heat Lamp Panel
.
2. Remove the
Surface Lights
.
3. Press the socket clamps in and pull the
socket from the overhead light panel.