Страница 1: ...GE Monogram Installation Instructions Component Cooktop System Models ZEW145V ZG W124 EN3 ZG W125EN3 ZEW155N ZEW166 Y ZEW176 Y ...

Страница 2: ...st products or combustion air required by gas furnaces gas water heaters fireplaces or other naturally vented systems To minimize the chance of interference with such naturally vented systems follow the heating equipment manufacturer s guidelines and local codes Also follow tim guidelines in ASHRAE Standard 62 1989 Ventilation for Acceptable Indoor Air Quality section 5 8 When following these guid...

Страница 3: ...ssembly on an outside wall Product Dimensions ZEW145V Halogen and Ribbon Component 240and 208volt dual rated Parts suf plied 44 flexible conduit Onejoiner strip Two sets clamping screws One chassis support brace Allow additional 1rl depth for clearance of flexible conduit ZEW155N Updraft Grill Cooktop Component 240volt Parts suf plied Grease collection jar 48 flexible conduit Onejoiner strip Two s...

Страница 4: ... Down aft Grill Shipped With Discharge On Left Side 14 1 2 ZGW124EN3 GasCooktop Component with right hand controls ZGW125EN3 GasCooktop Component with left hand controls Parts supplied with each 1 2 inlet pipe Pressure regulator One joiner strip Two sets clamping screws One chassis support brace NOTE Gas components are designed for natural gas operations and cannot be converted to P operation If i...

Страница 5: ...t comply with the National Fuel Gas Code ANSI Z223 1 latest edition UL A G A appi oved Installation Opdons Multiple gas and electric components can be combined to form one custom cooking ai i angenlent Multiple electric components can operate fl om a singlejunction box if local codes permit Multiple gas components can operate from a manifold as permitted by local codes Updraft components can be ve...

Страница 6: ...t not be less than 24 Working areas next to the cooktops should have 18 nAnimum clearance between the countertop and the cabinet bottom EXCEPTION Installation of a listed microwave oven or cooking appliance over the cooktop s shall conform to tile installation instructions packed with that appliance Installation must conform with local codes Clearances When installed electric components require th...

Страница 7: ...ps in separate cutouts This clearance does not apply when multiple component cooktops are installed in one cutout 4 Minimum Between Cutouts Side to Side Orientation NOTE Donot installa downdraftvent ina sideto side orientationbehinda gasorhalogencomponent This wouldrequirethe userto reachovera heatedsurface to accessthe control Find Dimension A in chart below and on the following page 1 3 4 Min to...

Страница 8: ...6Y Downdraft Grill Component 20 3 4 ZEW155N Updraft Grill Component 15 3 8 Downdraft Vent ZEW176Y Component 5 1 8 Joiner Strip Connectioi1 between two cooktops including updraft grill and nonwent side of downdrafl grill 3 4 Downdraft Joiner Strip Connectioi1 between cooktop and downdraft vent or vent side of downdrafl grill 1 4 Provide finished look to Cooktop and component cooktop Downdrafl arran...

Страница 9: ...owndraft _ Halogen 19 7 8 Vent RH Gas _Downdraft _ Halogen 35 1 2 Grill RH Gas Halogen Downdraft 344 8 Vent LH Gas _Downdraft _ Halogen 50 3 4 Grill RH Gas Halogen Downdraf L _7_ Halogen Vent Halogen RH Gas Halogen RH Gas LH Gas Downdraft _ Halogen Vent LH Gas B Downdraft _7 Halogen 54 3 4 Vent Downdraft _ Halogen 55 1 4 Vent RH Gas RH Gas Downdraft _ Downdraft _ Halogen Vent Grill RH Gas Halogen ...

Страница 10: ...nce Planning Use tile shortest and straightest duct run possible Duct run for Downdraft Grill Component ZEW166Y should not exceed equivalent length of 100 feet Duct run for Downdraft Vent ZEW176Y should not exceed equivalent length of 150 feet Refer to Duct Fittings chart to calculate equivalent length for various duct configurations The downdrafl blower system is designed for use with 3 1 4 x 10 ...

Страница 11: ...blower can be mounted in the cabinet or under tim floor The blower will fit between floorjoists on 16 centers For installation where the blower is mounted inside the cabinet attach the mounting supports to the bottom corners of the blower housing The motor is on the bottom side the 6 round opening is the top side If the blower is installed under the floor attach the mounting suf ports to the top c...

Страница 12: ...inimizettle chance d interruptionof sucllnaturally ventedsystems follow ttle heating equipmentmanufacturer s guidelinesand safetystandards suchasthosepublishedby NFPA andASHRAE Total Equivalent Quantity Equivalent Duct Piece Dimensions Lengtb Used Length lft 6 round pen foot straight length lit 3 1 4 x 10 pen foot straight lengtb 6 90 elboN 15 ft _ 6 45 elbow 9 ft 3 1 4 10 x 90 elbow 15 ft 3 1 4 x...

Страница 13: ...t off valve if supply is opted to enter from rear Both left and right controlled gas compo nents are illustrated together in order to compare their supply rough in locations Electrical Supply Halogen and ribbon components operate on 240 208 volt 60 Hz Updraft grill and downdraft grill components operate on 240 volt 60 Hz Gas and downdraft vent compo nents operate on 120 volt 60 Hz from a separate ...

Страница 14: ...ith a 5 16 n u tdriver Discard nuts Attach joiner strip to first cooktop by tightening flanged nuts supplied over the flanges Place the two cooktops into the countertop cutout Slide the cooktops together so that the slots in the joiner strip are engaged by the studs There should be no gaps between cooktops andjoiners Press together firmly to assure a tight fit Place flanged nuts in end of 5 16 nut...

Страница 15: ...through holes and then backing out before installation This will make the joining process easier Replace endcap with downdraft joiner strip using the same three nuts If the vent is to be installed at the end of the countertop opening attach downdraft endcap to that side Place the downdraft vent and cooktop into the cutout Remove two screws fl om the fl ont of cooktop chassis Drive the two screws i...

Страница 16: ...oining process easier Attach downdraft joiner strip to cooktop Place cooktop next to downdraft vent in the cutout Drive two i hillips head screws into pre tapped holes Use a phillips screwdriver bit socket To install additional vent or cooktop s refer to Joining Multiple Cooktops _ecllFe Cooktop s to Countertop Loosen screws on hold down brackets at each end of cooktop Extend the bracket to reach ...

Страница 17: ...stic plug fi om tim blower motor assembly to tim 3 pin plastic socket on tim underside of tim vent controls Fasten the wire box on tim conduit over tim l lug and onto tim bottom of tim control box with screws provided The blower conduit is long enough to reach the vent connection when installed in the cabinet below The conduit will also reach some blower installations below the cabinet floor If th...

Страница 18: ...gray Ground unit by connecting bare conductor of cooktop to branch circuit bare or green lead ground lead The fl ames of these appliances are grounded to neutral Updraft grill has no white neutral wire Connect only black red and bare wires as showl I 3 Conductor Branch Circuit 120VAC Neutral Branch Circuit Cooktop Red White or Gray White _ Bare or Green 120VAC Black _ Black 4 Conductor Branch Circ...

Страница 19: ...igh position Make sure each element heats up Gas Components Electrical connections should be complete Plug power cord into outlet Assemble burner s as shown Check for proper ignition Push in control knob and turn 90 to HIGH position First test may require some time while air is flushed out of the gas line Turn knob to OFF Repeat tile procedure for each burner _ _Burner er Cap Ring Do not operate t...

Страница 20: ...umer information service at 800 G2G 2000 tq _illle dltv o1 ii_hr For Monogram local service in yoln area call 1 800 ddd 18d5 NO It Product imprt vtqntqat is a c ntinuing endeavor at Gtq_ ral qectlic her R r materials mpealanct 7rod sp _cmcali_ns ar _ s_d ject _ change withotl I oliCe Pub No 49 8834 Dwg No 164D3333P076 1997 GE Appliances Printed il_ USA ND 751 97 General E ctr Company 953 0559 000 ...