For answers to your Monogram,
®
GE Profile
™
or
GE
®
appliance questions, visit our website at
ge.com or call GE Answer Center
®
service,
800.626.2000.
Listed by
Underwriters
Laboratories
Dimensions and Installation Information (in inches)
R
557ZEU669
16" Min
Junction
Box
21-1/4" at
center
1-3/4"
Min.
*3-1/4"
36"
33-7/8"
2-1/2"
Min.
to Front
Edge
19-1/8"
2" Min.
to Side Walls
605Dia128
Combination Installations
Consideration must be given to the electrical supply
locations when the cooktop is installed with other
products in the same cabinet. Always refer to each
product's installation instructions for clearances
and electrical requirements.
• Install these cooktops with any exhaust hood of the
same or greater width; 300 CFM or greater air flow.
• The cooktop may be installed with a 36" Monogram
downdraft vent.
Electrical Requirements
Product rating is 120/208V or 120/240V, 60Hz. For 240V,
connect to a 40-amp circuit; connect to a 30-amp circuit
for 208V operation. The cooktop must be connected to
a supply circuit of the proper voltage and frequency and
protected by a time-delay fuse or circuit breaker.
* 3-1/4" deep at the front. 4-5/8" deep at the rear conduit location.
Allow 5" minimum clearance below the cooktop bottom to
combustible materials.
Specification Created 12/04
130250
ZEU36KSK/WK/BK
GE Monogram
®
36" Ribbon Cooktop
R