background image

Dimensions and Installation Information (in inches)

Installation Flexibility 

These ovens may be installed in combination with a Monogram 
warming drawer. 

Note: 

Cabinets installed adjacent to wall ovens must have an  

adhesion spec of at least a 194°F temperature rating.

Installation Information

: Before installing, consult installation  

instructions packed with product for current dimensional data.

For answers to your Monogram,

® 

GE Profile

 or  

GE

®

 appliance questions, visit our website at 

ge.com or call GE Answer Center

®

 service,  

800.626.2000.

Specification Revised 5/07

130186

ZET958SM/BM/WM 

GE Monogram

®

 30” Built-In Double Oven

 

KW Rating

240V

8.0

208V

6.0

Breaker Size

240V

40 Amps

208V

40 Amps

Listed by 

Underwriters 

Laboratories

28-1/2" Min.

        28-5/8" Max.

51-13/16"

Min.

51-15/16"

Max.

12"

Locate Junction Box 47"

Above Cutout Floor, Within 5"

of Right Rear Wall

30"

52-7/8"

23-1/4"

Recessed

Depth

29-3/4"

23-1/2"

Min.

28-1/2" Min.

        28-5/8" Max.

51-13/16"

Min.

51-15/16"

Max.

12"

Locate Junction Box 47"

Above Cutout Floor, Within 5"

of Right Rear Wall

30"

52-7/8"

23-1/4"

Recessed

Depth

29-3/4"

23-1/2"

Min.

The solid bottom or runners must be level with the bottom of the 
cutout, or the bottom trim may not install correctly and could 
interfere with the door opening. If the cabinet does not have a 
solid bottom, two braces or runners must be installed level with 
the bottom of the cutout to support the weight of the oven. The 
runners and braces must support 300 lbs. (135 kg).

NOTE: Install the

oven only with

specific models

listed on the label

located on top of

the oven.

Anti-Tip Block

Against Rear

Wall Per

Warming

Drawer

Requirement

2

 

 (5.1 cm)

Min.

1

 

 (2.5 cm) Min. Above Toekick

Per Warming

Drawer

Requirement

Отзывы: