Dimensions and Installation Information (in inches)
Installation Flexibility
These ovens may be installed in combination with a Monogram
warming drawer.
Note:
Cabinets installed adjacent to wall ovens must have an
adhesion spec of at least a 194°F temperature rating.
Installation Information
: Before installing, consult installation
instructions packed with product for current dimensional data.
For answers to your Monogram,
®
GE Profile
™
or
GE
®
appliance questions, visit our website at
ge.com or call GE Answer Center
®
service,
800.626.2000.
Specification Revised 5/07
130186
ZET958SM/BM/WM
GE Monogram
®
30” Built-In Double Oven
KW Rating
240V
8.0
208V
6.0
Breaker Size
240V
40 Amps
208V
40 Amps
Listed by
Underwriters
Laboratories
28-1/2" Min.
28-5/8" Max.
51-13/16"
Min.
51-15/16"
Max.
12"
Locate Junction Box 47"
Above Cutout Floor, Within 5"
of Right Rear Wall
30"
52-7/8"
23-1/4"
Recessed
Depth
29-3/4"
23-1/2"
Min.
28-1/2" Min.
28-5/8" Max.
51-13/16"
Min.
51-15/16"
Max.
12"
Locate Junction Box 47"
Above Cutout Floor, Within 5"
of Right Rear Wall
30"
52-7/8"
23-1/4"
Recessed
Depth
29-3/4"
23-1/2"
Min.
The solid bottom or runners must be level with the bottom of the
cutout, or the bottom trim may not install correctly and could
interfere with the door opening. If the cabinet does not have a
solid bottom, two braces or runners must be installed level with
the bottom of the cutout to support the weight of the oven. The
runners and braces must support 300 lbs. (135 kg).
NOTE: Install the
oven only with
specific models
listed on the label
located on top of
the oven.
Anti-Tip Block
Against Rear
Wall Per
Warming
Drawer
Requirement
2
(5.1 cm)
Min.
1
(2.5 cm) Min. Above Toekick
Per Warming
Drawer
Requirement