05-2806A01, Rev. L
MDS iNET Series Reference Manual
61
Figure 2-49. Remote Radio Serial Port Configuration
2.6.10 Point-to-Point Serial-to-Serial Application Example
Once the transceivers are configured and the changes have been executed, they begin processing any data
presented at the
COM
ports. Data presented at the Access Point’s
COM
port will be packetized and sent via
UDP to the Remote. Upon receiving the packet, the Remote strips the data out of the UDP packet and sends
it out its
COM
port. Likewise, data presented at the Remote’s
COM
port is packetized, sent to the Access
Point, stripped, and sent out the Access Point’s
COM
port. This configuration does not use multicast
addressing.
Invisible place holder
Figure 2-50. Point-to-Point Serial-to-Serial Application Diagram
Table 2-3. Serial Port Application Configuration
Transceiver Location
Menu Item
Setting
Access Point (COM2)
1
Status
Enabled
Data Baud Rate
9,600 (Example)
Flow Control
Hardware (Example)
Serial Mode
Seamless
SIFD
2
4
IP Protocol
UDP
Remote IP
Address
192.168.0.2
(IP address of the Remote radio)
Remote IP Port
30011
Local IP Port
30011
EIA-232
RTU
EIA-232
Terminal
or Computer
192.168.0.10
192.168.0.1
192.168.0.2
Remote
Access Point
LA
N
COM
1
COM
2
PW
R
LIN
K
Содержание MDS iNET Series
Страница 12: ...x MDS iNET Series Reference Manual 05 2806A01 Rev L...
Страница 159: ...05 2806A01 Rev L MDS iNET Series Reference Manual 147 Figure A 22 EDS Wizard Completion Screen...
Страница 165: ...05 2806A01 Rev L MDS iNET Series Reference Manual 153 NOTES...
Страница 166: ...154 MDS iNET Series Reference Manual 05 2806A01 Rev L NOTES...
Страница 173: ...GE MDS LLC Rochester NY 14620 General Business 1 585 242 9600 FAX 1 585 242 9620 Web www gemds com 175 Science Parkway...