CHAPTER 5: SETTINGS
469 MOTOR MANAGEMENT RELAY – INSTRUCTION MANUAL
5–55
FIGURE 5–13: Voltage Dependent Overload Protection at 100% Voltage
Unbalance Bias
Unbalanced phase currents also cause additional rotor heating not accounted for by
electromechanical relays and also not accounted for in some electronic protective relays.
When the motor is running, the rotor rotates in the direction of the positive-sequence
current at near synchronous speed. Negative-sequence current, with a phase rotation
opposite to positive-sequence current (and hence, opposite to the rotor rotation),
generates a rotor voltage that produces a substantial rotor current. This induced current
has a frequency approximately 2 times the line frequency: 100 Hz for a 50 Hz system or
120 Hz for a 60 Hz system. The skin effect in the rotor bars at this frequency causes a
significant increase in rotor resistance and therefore a significant increase in rotor heating.
1
1
2
3
4
5
6
7
8
2
3
4
5
6
7
8
9
10
20
30
40
50
60
7
0
80
9
0
100
HIGH INERTIA LOAD OVERLOAD CURVES
8800 HP, 13.2 kV, REACTOR COOLANT PUMP
TIME
T
O
TRIP
(SECONDS)
MULTIPLES OF FULL LOAD AMPS
200
300
400
500
600
7
00
800
9
00
1000
GE Multilin
806826A4.CDR
Содержание Masoneilan 469 Series
Страница 4: ......
Страница 91: ...CHAPTER 3 INSTALLATION 469 MOTOR MANAGEMENT RELAY INSTRUCTION MANUAL 3 27 3 2 14 2 Speed Motor Wiring ...
Страница 92: ...3 28 469 MOTOR MANAGEMENT RELAY INSTRUCTION MANUAL CHAPTER 3 INSTALLATION ...
Страница 256: ...5 112 469 MOTOR MANAGEMENT RELAY INSTRUCTION MANUAL CHAPTER 5 SETTINGS ...
Страница 298: ...6 42 469 MOTOR MANAGEMENT RELAY INSTRUCTION MANUAL CHAPTER 6 ACTUAL VALUES ...
Страница 300: ...7 2 469 MOTOR MANAGEMENT RELAY INSTRUCTION MANUAL CHAPTER 7 TESTING FIGURE 7 1 Secondary Injection Test Setup ...
Страница 319: ...CHAPTER 8 APPENDIX 469 MOTOR MANAGEMENT RELAY INSTRUCTION MANUAL 8 7 HGF5C 808841A1 HGF8 808842A1 ...
Страница 321: ...CHAPTER 8 APPENDIX 469 MOTOR MANAGEMENT RELAY INSTRUCTION MANUAL 8 9 808712A1 CDR ...
Страница 330: ...8 18 469 MOTOR MANAGEMENT RELAY INSTRUCTION MANUAL CHAPTER 8 APPENDIX ...