background image

Remove the plastic battery isolation tag from the remote control by pulling it out. (see below picture B)
Point the remote control towards the IR Receive sensor on the White controller box. (see below picture C) 

 

Do not have the sensor pointing directly towards strong sunlight. The remote control need to be in line 

of sight to a maximum of around 5 metres from the Black sensor on the cable.

Locate and unfasten the first coaxial connector of the additional set to remove the control box.
Connect the exposed connection with open end connector from the first set
Repeat for all additional sets
Connect up to 3 sets only of GE brand StayBright® sets ONLY 

Encuentre y afloje el primer conector coaxial del juego adicional para quitar la caja de control
Conecte la conexión expuesta con el conector de extremo abierto del primer juego
Lo repite para todos los juegos adicionales
Conecte hasta 3 juegos solamente de equipos StayBright® de la marca GE SOLAMENTE

PRINTED IN/IMPRESO EN VIETNAM

 

 

MADE IN/HECHO EN VIETNAM

©2021 Nicolas Holiday Ltd., 9F., No. 37, Guangfu N. Rd. Taipei, Taiwan 10560. All rights reserved./Todos los derechos reservados

NV 0421

Remote control User Manual  / Manual del usuario de control remoto  

Picture/Imagen 

 C



  

 

    

 

 

     

    
    

    

    

    
    

    

Picture/Imagen B

 

IR R eceive

Product connection  /  Conexión de producto

For questions and/or assistance, call customer service at/Para dudas y/o asistencia,llame al servicio de atención al cliente al 

1-877-398-7337 or visit us on the web at/o visite nuestra web www.geholidaylighting.com

Quita y tirando la etiqueta de aislamiento de la batería de plástico del control remoto. (vea la imagen 

B de abajo)
Apunte el control remoto hacia el sensor de infrarrojos en la caja del controlador blanca. (vease siguiente 

imagen C)

No apunte el sensor directamente hacia la luz solar intensa. El control remoto debe estar en la línea de 

visión a un máximo de unos 5 metros desde el sensor negro en el cable

 

Sensor IR



   

 

     

  

    

  

ó

     

     

     

     

  

  

     

    

   

ó

  

Non-rechargeable batteries are not to be recharged.
Batteries are to be inserted with the correct polarity.

Exhausted batteries are to be removed from the product.
DO NOT DISPOSE OF BATTERIES IN FIRE. BATTERIES MAY EXPLODE OR LEAK.

Caution for ingestion(small batteries only).

Las baterías no recargables no se deben recargar.

Las baterías deben insertarse con la polaridad correcta.
Las pilas gastadas deben retirarse del producto.

NO TIRE LAS BATERÍAS AL FUEGO, A LO CONTRARIO SE EXPLOTARÁ O INCENDIARÁ.

Prevenir trago (solo baterías pequeñas).

Содержание LT-FCB-WF-5050-4W-30L-6M-Ex-C-RGB-120V

Страница 1: ...s where subject to flexing o Do not mount or secure tape light in a manner that can cut the outer jacket or damage the cord insulation Inspect the tape light carefully before use and discard any tape light that have broken outer jacket loose connections or frayed wire insulation p Risk of fire Do not replace attachment plug Contains a safety device fuse that should not be removed Discard product i...

Страница 2: ...Required Accessories Inclused B C B C B C C Part Descrip on Quan ty A Fuse 1 B Screw 14 C Clip 7 HOW TO REPLACE THE FUSE This plug contains an electrical fuse a safety feature Disconnect power before replacing the fuse Grasp plug and remove from the receptacle or other outlet device Do not unplug by pulling on the cord Slide open by unscrew the fuse access cover on top of attachment plug Remove ol...

Страница 3: ...que pueda cortar la cubierta exterior o dañar el aislamiento del cable Revise la cadena de luz con detenimiento antes de usarla y deseche cualquier cadena que tenga la cubierta exterior rota conexiones sueltas o el aislamiento del cable desgastado p Riesgo de incendio No sustituya el enchufe Contiene un dispositivo de seguridad fusible que no debe ser retirado Deseche el producto si el enchufe est...

Страница 4: ...je las pinzas de montaje con clavos o tornillos en las superficies de soporte La Figura 1 2 3 depende de los medios de montaje previstos del este producto consulte Parte de Accesorios E Deben disponer uniformemente las pinzas de montaje y la ventosa las ambas deben estar separados al máximo de 1M Figura 4 F Compruebe de que la distancia entre dos líneas de cadenas de iluminación sea al menos 12 mm...

Страница 5: ... NV 0421 Remote control User Manual Manual del usuario de control remoto Picture Imagen C Picture Imagen B IRRecei ve Product connection Conexión de producto For questions and or assistance call customer service at Para dudas y o asistencia llame al servicio de atención al cliente al 1 877 398 7337 or visit us on the web at o visite nuestra web www geholidaylighting com Quita y tirando la etiqueta...

Отзывы: