Autotrol 

  Series 255 Valve  

 

Series 263 Valve

 

 

 

                                                                      

Series 268 Valve

 

 
 
 
 

 

 

     

       

 

740C-ET & 760C-ET  

Controllers 

 

 
 

Quick Start Manual 

 
 
 
 
 

                                       

 

Содержание Logix 740C-ET

Страница 1: ...Autotrol Series 255 Valve Series 263 Valve Series 268 Valve 740C ET 760C ET Controllers Quick Start Manual ...

Страница 2: ...utes elapses verify that the motor is turning the camshaft If it is not turning see the troubleshooting section in Dealer Installation and Service Manual INITIAL START UP STEP BY STEP INSTRUCTIONS Step 1 Program System Size This step may have been performed by your system s OEM manufacturer In this case proceed to step 2 Input tank diameter size in inch 7 8 9 10 11 12 13 14 16 Use UP and DOWN butt...

Страница 3: ...tep 5b Set number of days between time clock regeneration regen frequency Default time is 3 days Days can be adjusted from 1 2 5 to 99 days To change press SET to make the 3 flash Use the UP and DOWN buttons to change to the number of days desired Press SET to accept the regen frequency and advance to the next cycle To use the 7 day timer option see full Dealer Installation Manual Step 5a Regenera...

Страница 4: ...salt amount choice To return to regeneration frequency the days selected for the regeneration have to be deactivated The values related to the days between two following regenerations could be not equal to zero Step 5b Set Calendar Override 760 Demand Control Only If using 740 control proceed to step 6 Set number of days for calendar override on demand control 0 days is the default for calendar ov...

Страница 5: ...ess SET to accept the setting and advance to the next parameter If using 740 control programming is complete The control will return you to the normal operation mode Step 8 Enter Hardness 760 Demand Control Only Enter inlet water hardness at installation site Default hardness setting is 10 ppm 1 F To change hardness value press SET to make the setting flash Use the UP and DOWN buttons to scroll to...

Страница 6: ...ckwash C2 Regenerant Draw Slow Rinse not used in filter mode C3 Slow Rinse not used in filter mode C4 System Pause to repressurize tank C5 Fast rinse cycle 1 C6 Backwash cycle 2 not used in filter mode C7 Fast Rinse cycle 2 not used in filter mode C8 Regenerant refill not used in filter mode RESETTING THE CONTROL To reset the control 1 Press and hold SET and DOWN simultaneously for 5 seconds 2 H0 ...

Страница 7: ...e and replace it with the chlorine generator refill flow control See the illustrations to the right for the location of the refill controller Step 4 Insert the large connector of the chlorine generator chord to the end of the refill flow control Press it in firmly to make sure there is good contact Step 5 Reconnect power to the Logix Control and reinstall the control to the valve No programming is...

Страница 8: ...sin Volume liters 5 5 7 16 6 5 9 20 11 24 32 13 28 28 38 47 47 Valve Model Injector Type Backwash I backwash C1 min Brine Draw slow rinse C2 min 37 5 48 5 104 5 32 42 96 5 38 5 83 5 109 32 5 73 5 79 5 86 5 107 116 Pressurization C4 min I fast rinse C5 min II backwash C6 min II fast rinse C7 min Refill C8 min 2 2 5 5 5 2 5 3 7 4 8 10 4 9 5 12 5 13 16 21 Regeneration total time min 53 5 65 124 48 5 ...

Страница 9: ... liters 60 65 65 65 75 75 100 100 100 125 125 125 Valve Model Injector Type Backwash I backwash C1 min Brine Draw slow rinse C2 min 88 95 104 5 67 5 78 86 86 92 101 5 84 90 100 Pressurization C4 min I fast rinse C5 min II backwash C6 min II fast rinse C7 min Refill C8 min 20 21 5 29 21 5 25 33 26 5 33 44 34 42 55 Regeneration total time min 123 131 5 148 5 108 122 138 131 5 144 164 5 139 153 176 M...