GE Multilin
L60 Line Phase Comparison Relay
B-39
APPENDIX B
B.4 MEMORY MAPPING
B
9B94
Teleprotection Channel 2 Number of Lost Packets
0 to 65535
---
1
F001
0
9B95
Teleprotection Network Status
0 to 2
---
1
F134
2 (n/a)
9BA0
Teleprotection Channel 1 Input States
0 to 1
---
1
F500
0
9BA1
Teleprotection Channel 2 Input States
0 to 1
---
1
F500
0
9BB0
Teleprotection Input 1 States, 1 per register (16 items)
0 to 1
---
1
F108
0 (Off)
9BC0
Teleprotection Input 2 States, 1 per register (16 items)
0 to 1
---
1
F108
0 (Off)
VT Fuse Failure (Read/Write Setting) (6 modules)
A040
VT Fuse Failure Function
0 to 1
---
1
F102
0 (Disabled)
A041
...Repeated for module number 2
A042
...Repeated for module number 3
A043
...Repeated for module number 4
A044
...Repeated for module number 5
A045
...Repeated for module number 6
Pilot POTT (Read/Write Setting)
A070
POTT Scheme Function
0 to 1
---
1
F102
0 (Disabled)
A071
POTT Permissive Echo
0 to 1
---
1
F102
0 (Disabled)
A072
POTT Rx Pickup Delay
0 to 65.535
s
0.001
F001
0
A073
POTT Transient Block Pickup Delay
0 to 65.535
s
0.001
F001
20
A074
POTT Transient Block Reset Delay
0 to 65.535
s
0.001
F001
90
A075
POTT Echo Duration
0 to 65.535
s
0.001
F001
100
A076
POTT Line End Open Pickup Delay
0 to 65.535
s
0.001
F001
50
A077
POTT Seal In Delay
0 to 65.535
s
0.001
F001
400
A078
POTT Ground Direction OC Forward
0 to 65535
---
1
F300
0
A079
POTT Rx
0 to 65535
---
1
F300
0
A07A
POTT Echo Lockout
0 to 65.535
s
0.001
F001
250
Selector Switch Actuals (Read Only)
A400
Selector 1 Position
1 to 7
---
1
F001
0
A401
Selector 2 Position
1 to 7
---
1
F001
1
Selector Switch (Read/Write Setting) (2 modules)
A410
Selector 1 Function
0 to 1
---
1
F102
0 (Disabled)
A411
Selector 1 Range
1 to 7
---
1
F001
7
A412
Selector 1 Timeout
3 to 60
s
0.1
F001
50
A413
Selector 1 Step Up
0 to 65535
---
1
F300
0
A414
Selector 1 Step Mode
0 to 1
---
1
F083
0 (Time-out)
A415
Selector 1 Acknowledge
0 to 65535
---
1
F300
0
A416
Selector 1 Bit0
0 to 65535
---
1
F300
0
A417
Selector 1 Bit1
0 to 65535
---
1
F300
0
A418
Selector 1 Bit2
0 to 65535
---
1
F300
0
A419
Selector 1 Bit Mode
0 to 1
---
1
F083
0 (Time-out)
A41A
Selector 1 Bit Acknowledge
0 to 65535
---
1
F300
0
A41B
Selector 1 Power Up Mode
0 to 2
---
1
F084
0 (Restore)
A41C
Selector 1 Target
0 to 2
---
1
F109
0 (Self-reset)
A41D
Selector 1 Events
0 to 1
---
1
F102
0 (Disabled)
A41E
Reserved (10 items)
---
---
1
F001
0
A428
...Repeated for Selector 2
DNP/IEC Points (Read/Write Setting)
A500
DNP/IEC 60870-5-104 Binary Input Points (256 items)
0 to 65535
---
1
F300
0
A600
DNP/IEC 60870-5-104 Analog Input Points (256 items)
0 to 65535
---
1
F300
0
Flexcurves C and D (Read/Write Setting)
A900
FlexCurve C (120 items)
0 to 65535
ms
1
F011
0
A978
FlexCurve D (120 items)
0 to 65535
ms
1
F011
0
Non Volatile Latches (Read/Write Setting) (16 modules)
AA00
Non-Volatile Latch 1 Function
0 to 1
---
1
F102
0 (Disabled)
AA01
Non-Volatile Latch 1 Type
0 to 1
---
1
F519
0 (Reset Dominant)
Table B–9: MODBUS MEMORY MAP (Sheet 32 of 47)
ADDR
REGISTER NAME
RANGE
UNITS
STEP
FORMAT
DEFAULT
Содержание L60
Страница 2: ......
Страница 4: ......
Страница 24: ...1 14 L60 Line Phase Comparison Relay GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1...
Страница 42: ...2 18 L60 Line Phase Comparison Relay GE Multilin 2 2 SPECIFICATIONS 2 PRODUCT DESCRIPTION 2...
Страница 78: ...3 36 L60 Line Phase Comparison Relay GE Multilin 3 3 DIRECT INPUT OUTPUT COMMUNICATIONS 3 HARDWARE 3...
Страница 368: ...8 28 L60 Line Phase Comparison Relay GE Multilin 8 2 SINGLE POLE TRIPPING 8 THEORY OF OPERATION 8...
Страница 470: ...D 10 L60 Line Phase Comparison Relay GE Multilin D 1 PROTOCOL APPENDIXD D...
Страница 482: ...E 12 L60 Line Phase Comparison Relay GE Multilin E 2 DNP POINT LISTS APPENDIXE E...
Страница 498: ...x L60 Line Phase Comparison Relay GE Multilin INDEX Z ZERO SEQUENCE CORE BALANCE 3 9...