AA02
Non-Volatile Latch 1 Set
0 to 65535
---
1
F300
0
AA03
Non-Volatile Latch 1 Reset
0 to 65535
---
1
F300
0
AA04
Non-Volatile Latch 1 Target
0 to 2
---
1
F109
0 (Self-reset)
AA05
Non-Volatile Latch 1 Events
0 to 1
---
1
F102
0 (Disabled)
AA06
Reserved (4 items)
---
---
---
F001
0
AA0A
...Repeated for Non-Volatile Latch 2
AA14
...Repeated for Non-Volatile Latch 3
AA1E
...Repeated for Non-Volatile Latch 4
AA28
...Repeated for Non-Volatile Latch 5
AA32
...Repeated for Non-Volatile Latch 6
AA3C
...Repeated for Non-Volatile Latch 7
AA46
...Repeated for Non-Volatile Latch 8
AA50
...Repeated for Non-Volatile Latch 9
AA5A
...Repeated for Non-Volatile Latch 10
AA64
...Repeated for Non-Volatile Latch 11
AA6E
...Repeated for Non-Volatile Latch 12
AA78
...Repeated for Non-Volatile Latch 13
AA82
...Repeated for Non-Volatile Latch 14
AA8C
...Repeated for Non-Volatile Latch 15
AA96
...Repeated for Non-Volatile Latch 16
Digital Counter (Read/Write Setting) (8 modules)
AB00
Digital Counter 1 Function
0 to 1
---
1
F102
0 (Disabled)
AB01
Digital Counter 1 Name
---
---
---
F205
“Counter 1"
AB07
Digital Counter 1 Units
---
---
---
F206
(none)
AB0A
Digital Counter 1 Block
0 to 65535
---
1
F300
0
AB0B
Digital Counter 1 Up
0 to 65535
---
1
F300
0
AB0C
Digital Counter 1 Down
0 to 65535
---
1
F300
0
AB0D
Digital Counter 1 Preset
-2147483647 to 2147483647
---
1
F004
0
AB0F
Digital Counter 1 Compare
-2147483647 to 2147483647
---
1
F004
0
AB11
Digital Counter 1 Reset
0 to 65535
---
1
F300
0
AB12
Digital Counter 1 Freeze/Reset
0 to 65535
---
1
F300
0
AB13
Digital Counter 1 Freeze/Count
0 to 65535
---
1
F300
0
AB14
Digital Counter 1 Set To Preset
0 to 65535
---
1
F300
0
AB15
Reserved (11 items)
---
---
---
F001
0
AB20
...Repeated for Digital Counter 2
AB40
...Repeated for Digital Counter 3
AB60
...Repeated for Digital Counter 4
AB80
...Repeated for Digital Counter 5
ABA0
...Repeated for Digital Counter 6
ABC0
...Repeated for Digital Counter 7
ABE0
...Repeated for Digital Counter 8
IEC 61850 GSSE Configuration (Read/Write Setting)
AD80
Default GSSE Update Time
1 to 60
s
1
F001
60
AD81
Remote Input/Output Transfer Method
0 to 2
---
1
F226
1 (GSSE)
AD82
IEC 61850 GOOSE VLAN Transmit Priority
0 to 7
---
1
F001
4
AD83
IEC 61850 GOOSE VLAN ID
0 to 4095
---
1
F001
0
AD84
IEC 61850 GOOSE ETYPE APPID
0 to 16383
---
1
F001
0
AD85
Reserved (22 items)
0 to 1
---
1
F001
0
IEC 61850 Server Configuration (Read/Write Settings/Commands)
ADA0
TCP Port Number for the IEC 61850 Protocol
1 to 65535
---
1
F001
102
ADA1
IEC 61850 Logical Device Name
---
---
---
F213
“IECDevice”
ADB1
Include Non-IEC 61850 Data
0 to 1
---
1
F102
1 (Enabled)
ADB2
Number of Status Indications in GGIO1
8 to 128
---
8
F001
8
ADB3
IEC 61850 Server Data Scanning Function
0 to 1
---
1
F102
0 (Disabled)
Table B–9: MODBUS MEMORY MAP (Sheet 33 of 47)
ADDR
REGISTER NAME
RANGE
UNITS
STEP
FORMAT
DEFAULT
Содержание L60
Страница 2: ......
Страница 4: ......
Страница 24: ...1 14 L60 Line Phase Comparison Relay GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1...
Страница 42: ...2 18 L60 Line Phase Comparison Relay GE Multilin 2 2 SPECIFICATIONS 2 PRODUCT DESCRIPTION 2...
Страница 78: ...3 36 L60 Line Phase Comparison Relay GE Multilin 3 3 DIRECT INPUT OUTPUT COMMUNICATIONS 3 HARDWARE 3...
Страница 368: ...8 28 L60 Line Phase Comparison Relay GE Multilin 8 2 SINGLE POLE TRIPPING 8 THEORY OF OPERATION 8...
Страница 470: ...D 10 L60 Line Phase Comparison Relay GE Multilin D 1 PROTOCOL APPENDIXD D...
Страница 482: ...E 12 L60 Line Phase Comparison Relay GE Multilin E 2 DNP POINT LISTS APPENDIXE E...
Страница 498: ...x L60 Line Phase Comparison Relay GE Multilin INDEX Z ZERO SEQUENCE CORE BALANCE 3 9...