
5-66
L60 Line Phase Comparison Relay
GE Multilin
5.4 FLEXLOGIC™
5 SETTINGS
5
Some operands can be re-named by the user. These are the names of the breakers in the breaker control feature, the ID
(identification) of contact inputs, the ID of virtual inputs, and the ID of virtual outputs. If the user changes the default name/
ID of any of these operands, the assigned name will appear in the relay list of operands. The default names are shown in
the FlexLogic™ operands table above.
The characteristics of the logic gates are tabulated below, and the operators available in FlexLogic™ are listed in the Flex-
Logic™ operators table.
INPUTS/OUTPUTS:
Virtual Inputs
Virt Ip 1
On
↓
Virt Ip 64
On
Flag is set, logic=1
↓
Flag is set, logic=1
INPUTS/OUTPUTS:
Virtual Outputs
Virt Op 1 On
↓
Virt Op 96 On
Flag is set, logic=1
↓
Flag is set, logic=1
LED TEST
LED TEST IN PROGRESS
An LED test has been initiated and has not finished.
REMOTE DEVICES
REMOTE DEVICE 1 On
↓
REMOTE DEVICE 16 On
Flag is set, logic=1
↓
Flag is set, logic=1
REMOTE DEVICE 1 Off
↓
REMOTE DEVICE 16 Off
Flag is set, logic=1
↓
Flag is set, logic=1
RESETTING
RESET OP
RESET OP (COMMS)
RESET OP (OPERAND)
RESET OP (PUSHBUTTON)
Reset command is operated (set by all 3 operands below)
Communications source of the reset command
Operand (assigned in the
INPUTS/OUTPUTS
RESETTING
menu) source
of the reset command
Reset key (pushbutton) source of the reset command
SELF-
DIAGNOSTICS
ANY MAJOR ERROR
ANY MINOR ERROR
ANY SELF-TEST
BATTERY FAIL
DIRECT DEVICE OFF
DIRECT RING BREAK
DSP ERROR
EEPROM DATA ERROR
EQUIPMENT MISMATCH
FLEXLOGIC ERR TOKEN
IRIG-B FAILURE
LATCHING OUT ERROR
LOW ON MEMORY
NO DSP INTERRUPTS
PRI ETHERNET FAIL
PROGRAM MEMORY
PROTOTYPE FIRMWARE
REMOTE DEVICE OFF
SEC ETHERNET FAIL
SNTP FAILURE
SYSTEM EXCEPTION
UNIT NOT CALIBRATED
UNIT NOT PROGRAMMED
WATCHDOG ERROR
Any of the major self-test errors generated (major error)
Any of the minor self-test errors generated (minor error)
Any self-test errors generated (generic, any error)
See description in Chapter 7: Commands and Targets.
See description in Chapter 7: Commands and Targets.
See description in Chapter 7: Commands and Targets.
See description in Chapter 7: Commands and Targets.
See description in Chapter 7: Commands and Targets.
See description in Chapter 7: Commands and Targets.
See description in Chapter 7: Commands and Targets.
See description in Chapter 7: Commands and Targets.
See description in Chapter 7: Commands and Targets.
See description in Chapter 7: Commands and Targets.
See description in Chapter 7: Commands and Targets.
See description in Chapter 7: Commands and Targets.
See description in Chapter 7: Commands and Targets.
See description in Chapter 7: Commands and Targets.
See description in Chapter 7: Commands and Targets.
See description in Chapter 7: Commands and Targets.
See description in Chapter 7: Commands and Targets.
See description in Chapter 7: Commands and Targets.
See description in Chapter 7: Commands and Targets.
See description in Chapter 7: Commands and Targets.
See description in Chapter 7: Commands and Targets.
UNAUTHORIZED
ACCESS ALARM
UNAUTHORIZED ACCESS
Asserted when a password entry fails while accessing a password-protected
level of the relay.
USER-
PROGRAMMABLE
PUSHBUTTONS
PUSHBUTTON x ON
PUSHBUTTON x OFF
Pushbutton Number x is in the ’On’ position
Pushbutton Number x is in the ’Off’ position
Table 5–8: FLEXLOGIC™ GATE CHARACTERISTICS
GATES
NUMBER OF INPUTS
OUTPUT IS ‘1’ (= ON) IF...
NOT
1
input is ‘0’
OR
2 to 16
any input is ‘1’
AND
2 to 16
all inputs are ‘1’
NOR
2 to 16
all inputs are ‘0’
NAND
2 to 16
any input is ‘0’
XOR
2
only one input is ‘1’
Table 5–7: L60 FLEXLOGIC™ OPERANDS (Sheet 7 of 7)
OPERAND TYPE
OPERAND SYNTAX
OPERAND DESCRIPTION
Содержание L60
Страница 2: ......
Страница 4: ......
Страница 24: ...1 14 L60 Line Phase Comparison Relay GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1...
Страница 42: ...2 18 L60 Line Phase Comparison Relay GE Multilin 2 2 SPECIFICATIONS 2 PRODUCT DESCRIPTION 2...
Страница 78: ...3 36 L60 Line Phase Comparison Relay GE Multilin 3 3 DIRECT INPUT OUTPUT COMMUNICATIONS 3 HARDWARE 3...
Страница 368: ...8 28 L60 Line Phase Comparison Relay GE Multilin 8 2 SINGLE POLE TRIPPING 8 THEORY OF OPERATION 8...
Страница 470: ...D 10 L60 Line Phase Comparison Relay GE Multilin D 1 PROTOCOL APPENDIXD D...
Страница 482: ...E 12 L60 Line Phase Comparison Relay GE Multilin E 2 DNP POINT LISTS APPENDIXE E...
Страница 498: ...x L60 Line Phase Comparison Relay GE Multilin INDEX Z ZERO SEQUENCE CORE BALANCE 3 9...