LP Conversion Instructions
CONVERT SURFACE BURNERS
Remove all grates and burner modules.
With an adjustable wrench or an open end wrench,
remove the brass orifices.
Find the inscribed LP orifices in the holder in the front
of the electric cover beneath the cooktop.
Install the inscribed LP orifices in place of the natural
gas orifices.
Replace the burner modules and grates.
Keep all the spuds with your cooktop so you have
them if you move or get a different gas hook-up.
F
E
D
C
B
A
2
LP (Propane) Gas 10
″
W.C.P.
Burner Output Rating in BTU/HR
Location
BTUs
Orifice Size
Engraving
Left Rear (LR)
9,100
.0354
LP
Left Front (LF)
9,100
.0354
LP
Right Rear (RR)
9,100
.0354
LP
Right Front (RF)
9,100
.0354
LP
Turn counterclockwise to remove
Orifice
Turn clockwise to tighten
ADJUST GRILL BURNER AIR SHUTTER
The air shutters for the grill burner may need to be
adjusted to get better flame appearance and ignition.
The air shutters for the grill burner are located on
the bottom of the grill burner. To access the air shutters,
remove the grill grate, and then the grill burner. Loosen
the screw and slide the air shutter backward or forward
to increase or decrease the size of the air opening.
Re-tighten the screw.
3
Air shutter
Loosen screw
Adjust air shutter opening
Tighten screw
CHECK IGNITION
Connect electrical supply cord.
Turn on the gas; check for leaks using a liquid leak
detector at all joints in the system.
WARNING:
DO NOT USE A FLAME
TO CHECK FOR GAS LEAKS.
Push in one control knob
and turn to the LITE position.
The igniter will spark and the
burner will light. The first test
may require some time while air
is flushed out of the gas line. After
ignition, turn the control knob to
the HI position and wait until the flame settles.
Check to determine if your burner flames are normal.
If burner flames look like A, turn off the burner and
make sure all parts are assembled correctly.
Reassemble and check.
Normal burner flames should look like B or C,
depending on the type of gas you use. With LP gas,
some yellow tipping on outer cones is normal.
Turn the knob to OFF.
Repeat the procedure for each burner.
E
D
C
B
A
4
A–Yellow flames
Not normal;
check
alignments
B–Yellow tips
Normal for
LP gas
C–Soft blue flames
Normal for