1.5 INSTALLATION
The following section provides information for installing an 86445-31 FXS unit.
The unit is shipped from the factory configured as per the Node Assignment
Drawing for the purchased system. All spare units or loose units are shipped
with factory default settings in memory.
CAUTION
The 86445-31 2W FXS unit has ESDS components and therefore standard
static protection
precautions should be observed when handling, packing
or shipping the unit.
Pre-installation
Visually check the unit for damage. Ensure that screws are firmly tightened and
in place. Keep the shipping containers and packing materials for future use. If a
unit is damaged, file a claim with the shipping agent or the local GE Multilin
representative.
Set the unit line impedance, network build-out capacitance (NBOC), and current
limiting as desired. Refer to the strapping options in Table 1. Factory default
settings are 600
Ω
for line impedance, 0nF for NBOC, and 20mA for current
limiting.
Function Jumper
Notes
NBOC 1
P4-19 to P4-20
Adds 22 nF to network build-out capacitance
NBOC 2
P4-17 to P4-18
Adds 47 nF to network build-out capacitance
R=900
Ω
P4-13 to P4-14
Line impedance at 2W VF port
R=600
Ω
P4-15 to P4-16
Line impedance at 2W VF port
Z=R
P4-11 to P4-12
Sets impedance to resistive only
Z=R+Xc
P4-9 to P4-10
Adds capacitive reactance to impedance (2.15 µF in
series)
P4-1 to P4-2
Current limiting is 20 mA
P4-3 to P4-4
Current limiting is 30 mA
P4-5 to P4-6
Current limiting is 40 mA
Current
Limiting
P4-7 to P4-8
Current limiting is 50 mA
Table 1:
86445-31 FXS Unit Strapping Options