background image

For answers to your Monogram,

® 

GE Profile

 or  

GE

®

 appliance questions, visit our website at 

ge.com or call GE Answer Center

®

 service,  

800.626.2000.

321356

Specification Created 10/06

Listed by 

Underwriters 

Laboratories

JP346SMSS 

GE

® 

30" Built-In CleanDesign Electric Cooktop

Dimensions and Installation Information (in inches) 

Note:

 If installing with a GE Profile

 Telescopic 

Downdraft System, consult both cooktop and 

downdraft installation instructions packed with 

product before installing. Cooktop gas/electric supply 

may need to be re-routed to install downdraft. 

Note:

 Consult cabinet and countertop 

manufacturer’s specs for flush mount installation 

prior to install.

Installation Information:

 Requires a 5" free 

area between the bottom of the  cooktop to any 

combustible material, i.e., shelving. Free area not required when installing 

wall oven underneath cooktop. Refer to installation instructions. Requires 

a 15" minimum from cooktop to adjacent overhead cabinets. Units are 

furnished with a 48" flexible armored cable.
Before installing consult installation instructions, packed with product, for 

current dimensional data. 36" Ribbon cooktops are approved for use over GE 

30" Single Wall Ovens only. 30" Ribbon cooktops are approved for use over 

select GE 27" and GE 30" Single Wall Ovens. Refer to cooktop and wall oven 

installation instructions packed with product for current dimensional data.

Filler Trim Kit

 

When replacing an old GE 30" cooktop (with larger opening) use the following 

one-piece trim kit to fill in the over-size hole. Available at additional cost.

JXTR32B (Black glass with black, white or bisque pattern)

3-1/4*

Cooktop

2-1/2**

Required

28-1/2

19-5/8

29-7/8

30_ss_cktp_install.eps

21-1/2

Electrical junction box 16" MIN. 

below countertop

30" MIN. to

unprotected

cabinet

Cut should 

not interfere 

with cabinet

structure 

at front

1-1/2" MIN.

clearance to

side wall

from cut-out

1-1/2" MIN.

clearance to

side wall

from cut-out

1-3/4" to

rear wall

13" MAX.

depth

  * Depth of unit at conduit connection location (rear) is 

6-1/2" on models PP980/950 and 4-5/8" on models 

PP975/972/962/945/942/932/912, JP655/356/346.

 **Raised bull nose countertops may require up to 

3/8" additional clearance to prevent interference 

with curved front.

15" MIN.  

to cabinet

KW Rating

240V

7.6

208V

5.7

Breaker Size

240V

40 Amps

208V

30 Amps

Отзывы: