![GE Hydran 201i Скачать руководство пользователя страница 228](http://html.mh-extra.com/html/ge/hydran-201i/hydran-201i_instruction-manual_128390228.webp)
Chapter 12 • Troubleshooting
12-12
Rev. 6, March 2011
Part 17997
12.1.20 SensTemp H
•
Alarm type
: Fail alarm
•
Non-abbreviated description
: Sensor temperature High
•
Priority
: Low
•
Parameter(s) involved
:
–
SensTemp H
;
SysOK Relay;FaultTrig.
submenu; Section 4.5.7 on page 4-23
–
STempAlr H
(alarm set point);
Temperature
submenu; Section 4.5.3 on page 4-17
–
TempoAlr Delay
;
Temperature
submenu; Section 4.5.3 on page 4-17
•
Alarm cause(s)
: Temperature of the Hydran 201 sensor above the
STempAlr H
alarm
set point
Although the H201 sensor is not affected by the temperature, monitor its temperature
regularly.
12.1.21 SensTemp HH
•
Alarm type
: Fail alarm
•
Non-abbreviated description
: Sensor temperature High-High
•
Priority
: Medium
•
Parameter(s) involved
:
–
SensTemp HH
;
SysOK Relay;FaultTrig.
submenu; Section 4.5.7 on page 4-23
–
STempAlr HH
(alarm set point);
Temperature
submenu; Section 4.5.3 on page 4-17
–
TempoAlr Delay
;
Temperature
submenu; Section 4.5.3 on page 4-17
•
Alarm cause(s)
: Temperature of the Hydran 201 sensor above the
STempAlr HH
alarm
set point
Proceed as follows:
1.
The oil is probably too hot at the location where the H201 sensor is installed; install
the Hydran 201T
i
at another location on the transformer tank, preferably at the
bottom. For details on typical installations, see Section 5.2.2.2 on page 5-10.
2.
If not already done, install the finned, high-temperature adaptor shown in Figure B-6
on page B-4; it can be purchased from General Electric Canada.
CAUTION
WARNING
Exposing the H201 sensor to temperatures above the STempAlr HH
alarm set point can damage the sensor.
Содержание Hydran 201i
Страница 1: ...GE Energy Services Digital Energy Hydran Instruction Manual 201i System ...
Страница 6: ...Instruction Manual vi Rev 6 March 2011 Part 17997 PAGE LEFT INTENTIONALLY BLANK ...
Страница 8: ...Instruction Manual viii Rev 6 March 2011 Part 17997 PAGE LEFT INTENTIONALLY BLANK ...
Страница 22: ...Instruction Manual xxii Rev 6 March 2011 Part 17997 PAGE LEFT INTENTIONALLY BLANK ...
Страница 36: ...Chapter 1 Introduction 1 10 Rev 6 March 2011 Part 17997 PAGE LEFT INTENTIONALLY BLANK ...
Страница 72: ...Chapter 3 Hydran 201Ci Controllers 3 16 Rev 6 March 2011 Part 17997 PAGE LEFT INTENTIONALLY BLANK ...
Страница 114: ...Chapter 5 Before Installation 5 16 Rev 6 March 2011 Part 17997 PAGE LEFT INTENTIONALLY BLANK ...
Страница 143: ...Installation Part 17997 Rev 6 March 2011 6 29 Figure 6 9 Installing the CPU Module ...
Страница 176: ...Chapter 8 Hydran 201Ci 1 Installation 8 16 Rev 6 March 2011 Part 17997 PAGE LEFT INTENTIONALLY BLANK ...
Страница 190: ...Chapter 9 Communications and Networking 9 14 Rev 6 March 2011 Part 17997 PAGE LEFT INTENTIONALLY BLANK ...
Страница 216: ...Chapter 11 Operating the Hydran 201i System 11 8 Rev 6 March 2011 Part 17997 PAGE LEFT INTENTIONALLY BLANK ...
Страница 236: ...Chapter 12 Troubleshooting 12 20 Rev 6 March 2011 Part 17997 PAGE LEFT INTENTIONALLY BLANK ...
Страница 244: ...Chapter 13 Maintenance 13 8 Rev 6 March 2011 Part 17997 PAGE LEFT INTENTIONALLY BLANK ...
Страница 254: ...Appendix B Mechanical Drawings B 2 Rev 6 March 2011 Part 17997 Figure B 3 1 5 In Adaptor ...
Страница 255: ...Hydran 201Ti Intelligent Transmitter Part 17997 Rev 6 March 2011 B 3 Figure B 4 1 In Adaptor ...
Страница 262: ...Appendix C Functional Block Diagrams C 4 Rev 6 March 2011 Part 17997 PAGE LEFT INTENTIONALLY BLANK ...
Страница 282: ...Appendix F Default Values of the Parameters F 4 Rev 6 March 2011 Part 17997 PAGE LEFT INTENTIONALLY BLANK ...
Страница 284: ...Appendix G Unit Conversions G 2 Rev 6 March 2011 Part 17997 PAGE LEFT INTENTIONALLY BLANK ...
Страница 298: ...Appendix I Glossary I 12 Rev 6 March 2011 Part 17997 PAGE LEFT INTENTIONALLY BLANK ...
Страница 299: ......