background image

INSTALL TUBING

Push the tubing firmly into the collet on the

faucet adapter fitting until the pencil mark 

is pushed next to the collet. (If the tubing 

is removed, recut the end, measure, mark 

and reinsert.)

Tubing must be fully inserted to avoid leaks.
To remove tubing: Depress and hold the white

collet; pull the tubing out to remove.

Pull out slightly on the tubing to ensure a good seal.
Press the other end of the tubing into the outlet

side of the filter.

6

C

B

A

3

Installation Instructions

CUTTING THE TUBING

Determine the length of tubing necessary from

the filter head/bracket to the faucet and from the

water supply line to the filter head/bracket by

holding the tubing in place to ensure it is the

correct length.

NOTE:

6 feet of tubing is supplied. Cut the 

tubing into two sections according to your

requirements.
Cut tubing.

NOTE: 

Do not kink tubing.

NOTE: 

Check the end of the tubing to make sure

there are no cuts, nicks, flat spots or sharp edges.

If any of these are present, cut the end of the

tube with a utility knife.
Measure 3/4” from the end of the tubing

provided and mark with a pencil. 

B

A

C

5

INSTALL THE HEAD/BRACKET

Using the filter head/bracket as a guide, mark

hole locations so that there is 1” between the

center of each screw. Fasten the filter

head/bracket to the wall with the Phillips screws

provided with the unit.

NOTE:

Predrill 1/8

holes for easier installation.

Make sure to leave at least 2-1/2”

from the bottom of the system 

to allow for easy replacement 

of the filter cartridge.
Install screws only halfway so

you can slip the bracket onto the wall during

installation.

NOTE:

There are three installation configurations.

Select the appropriate screws for installation: For

Cabinet Side Wall Installations, use 1

screws; For

Drywall into Stud Installations, use 1-1/4

screws; 

For Drywall with No Stud Installations, use lag bolts.

CAUTION:

Be sure screw point does not

protrude through the wall into adjacent cabinet.

Tighten screws to secure the bracket.

D

C

B

A

4

2-1/2”

3/4” 

INCORRECT CUT

CORRECT CUT

3

4

"

Engagement

3/4” (1/4” tubing)

White Collet 

(DO NOT REMOVE)

Pencil mark line

Insert tubing

3/4”

INSTALL FAUCET ADAPTER

Install the 3/8” x 1/2” faucet adapter to the faucet

threads.
DO NOT OVERTIGHTEN.
Option A – Typical Installation

Option B – Optional Installation
If you have copper tubing with a compression

adapter, you will NOT use the 1/2” faucet adapter.
Use a section of tubing, slide the compression

hex nut and 3/8” ferrule (tapered end away from

the compression nut) onto the tubing, and put in

the tubing insert.

3

3/8” Compression adapter

Copper tubing

Insert

Ferrule

Hex nut

Tubing

Adapter

Faucet Threads

Содержание GXULQ

Страница 1: ...he Installation Instructions before it is used Check with your local public works department for plumbing codes You must follow their guides as you install the Kitchen and Bath Main Faucet Filtration...

Страница 2: ...rtically or horizontally DO NOT MOUNT THE SYSTEM UPSIDE DOWN B A 1 DISCONNECT COLD WATER SUPPLY Remove items from under the sink Place a bucket and some towels under the sink to collect any water that...

Страница 3: ...between the center of each screw Fasten the filter head bracket to the wall with the Phillips screws provided with the unit NOTE Predrill 1 8 holes for easier installation Make sure to leave at least...

Страница 4: ...General Contactusatge com orcalltoll freeat800 952 5039intheU S or866 777 7627inCanada Installation Instructions FINAL CHECK Insert the filter into the filter head bracket Turn the filter 1 4 turn to...

Страница 5: ...5 Notes...

Страница 6: ...e filtre l ext rieur ou un endroit expos au rayonnement solaire 6 MESURES DE S CURIT Consultez le service local des travaux publics au sujet des codes de plomberie et de raccordement aux gouts L insta...

Страница 7: ...t Effluent Reduction R duction Param tre MCL influent concentration moyen Moyenne Maximum Moyenne Minimum moyenne Go t et odeur de chlore 2 0 mg L 10 1 9 mg L 0 05 mg L 0 05 mg L 97 4 97 4 50 Particul...

Страница 8: ...installation S lectionnez les vis qui conviennent votre configuration pour une installation sur la paroi lat rale d une armoire utilisez des vis de 1 pour une installation sur cloison s che avec mont...

Страница 9: ...dans l autre Apr s l installation de nouvelles piles ou un changement de filtre poussez et tenez enfonc le bouton bleu de r initialisation du minuteur pendant environ 5 secondes Rel chez le bouton apr...

Страница 10: ...s particuliers mais vous pouvez galement avoir d autres droits qui varient d tat tat Pour conna tre vos droits juridiques consultez le bureau de protection du consommateur de votre localit de votre ta...

Страница 11: ...Notes 11...

Страница 12: ...las Instrucciones de instalaci n antes de ser usado Consulte con su departamento de obras p blicas local para los c digos de plomer a Usted debe seguir sus gu as a medida que instale el Sistema de fi...

Страница 13: ...l hasta seis meses Medici n en part culas ml Las part culas usadas eran de 0 5 1 micr n Requisitos de presi n 20 100 psi 1 4 6 9 bar Temperatura 1 1 38 C 34 100 F CALIENTE FR A ENTRADA SALIDA Instala...

Страница 14: ...ciones de las paredes laterales del gabinete use tornillos de 1 Para paneles de yeso con instalaciones con montajes use tornillos de 1 1 4 Para paneles de yeso sin instalaciones con montajes use perno...

Страница 15: ...OTA Para v lvulas de cierre con ajustes de compresi n de 1 2 o 7 16 utilice adaptadores adecuados incluidos con el kit Conecte el otro extremo del lado de la entrada como lo indica la flecha de la cab...

Страница 16: ...icos y usted podr a tener otros derechos que variar n de estado aestado Para saber cu les son sus derechos legales consulte a la oficina de asuntos del consumidor local o la oficina del Attorney Gener...

Отзывы: