Dimensions and Installation Information 

For answers to your Monogram,

® 

GE Profile

 or  

GE

®

 appliance questions, visit our website at 

ge.com or call GE Answer Center

®

 service, 

800.626.2000.

Dimension and installation information are shown in inches.

Listed by 

Underwriters 

Laboratories

PGP989SN 

GE Profile

™ 

30" Downdraft Gas Cooktop

 

Specification Revised 4/09

230285

Installing the Ductwork: 

Use galvanized  

or aluminum duct in 6” round or 3-1/4” x  
10” size, or combination of both. 

PVC duct 

or locally approved piping should be used 

if installing under a poured concrete slab.

 

Local building code must be followed in  
specifying type and schedule of all duct used.

Note: 

Ductwork must be vented to outside. 

Do not vent into a wall, ceiling, crawlspace, 
attic or any concealed space. Always use  
an appropriate roof or wall cap with damper. 

Laundry-type wall caps should never 

be used. 

For maximum efficiency use the 

shortest and straightest duct run possible, 
with as few fittings as possible.  
For satisfactory performance the duct run 
should not exceed 100 feet equivalent length.  
Refer to the table of equivalent lengths  
(shown in installation instructions) for  
various duct configurations.

Rear Wall Venting

Downward Venting

Venting Options

Through Cabinet Toe Space

Inside Wall to Roof

Direct to Outside

Between Floor Joist

9-1/8

10-1/8

18-3/4

6-1/8