GE Multilin
G60 Generator Protection System
B-45
APPENDIX B
B.4 MEMORY MAPPING
B
AA15
...Repeated for IEC 61850 GOOSE analog input 4
AA1C
...Repeated for IEC 61850 GOOSE analog input 5
AA23
...Repeated for IEC 61850 GOOSE analog input 6
AA2A
...Repeated for IEC 61850 GOOSE analog input 7
AA31
...Repeated for IEC 61850 GOOSE analog input 8
AA38
...Repeated for IEC 61850 GOOSE analog input 9
AA3F
...Repeated for IEC 61850 GOOSE analog input 10
AA46
...Repeated for IEC 61850 GOOSE analog input 11
AA4D
...Repeated for IEC 61850 GOOSE analog input 12
AA54
...Repeated for IEC 61850 GOOSE analog input 13
AA5B
...Repeated for IEC 61850 GOOSE analog input 14
AA62
...Repeated for IEC 61850 GOOSE analog input 15
AA69
...Repeated for IEC 61850 GOOSE analog input 16
IEC 61850 XCBR configuration (read/write settings)
AB24
Operand for IEC 61850 XCBR1.ST.Loc status
0 to 65535
---
1
F300
0
AB25
Command to clear XCBR1 OpCnt (operation counter)
0 to 1
---
1
F126
0 (No)
AB26
Operand for IEC 61850 XCBR2.ST.Loc status
0 to 65535
---
1
F300
0
AB27
Command to clear XCBR2 OpCnt (operation counter)
0 to 1
---
1
F126
0 (No)
AB28
Operand for IEC 61850 XCBR3.ST.Loc status
0 to 65535
---
1
F300
0
AB29
Command to clear XCBR3 OpCnt (operation counter)
0 to 1
---
1
F126
0 (No)
AB2A
Operand for IEC 61850 XCBR4.ST.Loc status
0 to 65535
---
1
F300
0
AB2B
Command to clear XCBR4 OpCnt (operation counter)
0 to 1
---
1
F126
0 (No)
AB2C
Operand for IEC 61850 XCBR5.ST.Loc status
0 to 65535
---
1
F300
0
AB2D
Command to clear XCBR5 OpCnt (operation counter)
0 to 1
---
1
F126
0 (No)
AB2E
Operand for IEC 61850 XCBR6.ST.Loc status
0 to 65535
---
1
F300
0
AB2F
Command to clear XCBR6 OpCnt (operation counter)
0 to 1
---
1
F126
0 (No)
IEC 61850 LN name prefixes (read/write settings)
AB30
IEC 61850 logical node LPHD1 name prefix
0 to 65534
---
1
F206
(none)
AB33
IEC 61850 logical node PIOCx name prefix (72 items)
0 to 65534
---
1
F206
(none)
AC0B
IEC 61850 logical node PTOCx name prefix (24 items)
0 to 65534
---
1
F206
(none)
AC53
IEC 61850 logical node PTUVx name prefix (13 items)
0 to 65534
---
1
F206
(none)
AC7A
IEC 61850 logical node PTOVx name prefix (10 items)
0 to 65534
---
1
F206
(none)
AC98
IEC 61850 logical node PDISx name prefix (10 items)
0 to 65534
---
1
F206
(none)
ACB6
IEC 61850 logical node RBRFx name prefix (24 items)
0 to 65534
---
1
F206
(none)
ACFE
IEC 61850 logical node RPSBx name prefix
0 to 65534
---
1
F206
(none)
AD01
IEC 61850 logical node RRECx name prefix (6 items)
0 to 65534
---
1
F206
(none)
AD13
IEC 61850 logical node MMXUx name prefix (6 items)
0 to 65534
---
1
F206
(none)
AD25
IEC 61850 logical node GGIOx name prefix (5 items)
0 to 65534
---
1
F206
(none)
AD34
IEC 61850 logical node RFLOx name prefix (5 items)
0 to 65534
---
1
F206
(none)
AD43
IEC 61850 logical node XCBRx name prefix (6 items)
0 to 65534
---
1
F206
(none)
AD55
IEC 61850 logical node PTRCx name prefix (6 items)
0 to 65534
---
1
F206
(none)
AD67
IEC 61850 logical node PDIFx name prefix (6 items)
0 to 65534
---
1
F206
(none)
AD73
IEC 61850 logical node MMXNx name prefix (6 items)
0 to 65534
---
1
F206
(none)
ADE2
IEC 61850 logical node CSWIx name prefix (6 items)
0 to 65534
---
1
F206
(none)
AE3C
IEC 61850 logical node XSWIx name prefix (6 items)
0 to 65534
---
1
F206
(none)
IEC 61850 XSWI configuration (read/write settings)
AECF
Operand for IEC 61850 XSWI1.ST.Loc status
0 to 65535
---
1
F300
0
AED0
Command to clear XSWI1 OpCnt (operation counter)
0 to 1
---
1
F126
0 (No)
AED1
Repeated for IEC 61850 XSWI2
AED3
Repeated for IEC 61850 XSWI3
AED5
Repeated for IEC 61850 XSWI4
AED7
Repeated for IEC 61850 XSWI5
AED9
Repeated for IEC 61850 XSWI6
AEDB
Repeated for IEC 61850 XSWI7
Table B–9: MODBUS MEMORY MAP (Sheet 38 of 58)
ADDR
REGISTER NAME
RANGE
UNITS
STEP
FORMAT
DEFAULT
Содержание G60 UR Series
Страница 2: ......
Страница 4: ......
Страница 12: ...xii G60 Generator Protection System GE Multilin TABLE OF CONTENTS ...
Страница 32: ...1 20 G60 Generator Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Страница 102: ...3 48 G60 Generator Protection System GE Multilin 3 4 MANAGED ETHERNET SWITCH MODULES 3 HARDWARE 3 ...
Страница 132: ...4 30 G60 Generator Protection System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Страница 392: ...5 260 G60 Generator Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Страница 418: ...6 26 G60 Generator Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Страница 446: ...8 18 G60 Generator Protection System GE Multilin 8 3 ENERVISTA SECURITY MANAGEMENT SYSTEM 8 SECURITY 8 ...
Страница 452: ...9 6 G60 Generator Protection System GE Multilin 9 1 PHASE DISTANCE THROUGH POWER TRANSFORMERS 9 THEORY OF OPERATION 9 ...
Страница 482: ...A 12 G60 Generator Protection System GE Multilin A 1 PARAMETER LISTS APPENDIXA A ...
Страница 604: ...D 10 G60 Generator Protection System GE Multilin D 1 IEC 60870 5 104 APPENDIXD D ...
Страница 616: ...E 12 G60 Generator Protection System GE Multilin E 2 DNP POINT LISTS APPENDIXE E ...
Страница 634: ...x G60 Generator Protection System GE Multilin INDEX ...