6 ACTUAL VALUES
6.2 STATUS
6
6.2.15 IEC 61850 GOOSE INTEGERS
PATH: ACTUAL VALUES
ÖØ
STATUS
ÖØ
IEC 61850 GOOSE UINTEGERS
The G60 Generator Protection System is provided with optional IEC 61850 communications capability.
This feature is specified as a software option at the time of ordering. Refer to the
Ordering
section of chap-
ter 2 for additional details. The IEC 61850 protocol features are not available if CPU type E is ordered.
The IEC 61850 GGIO5 integer input data points are displayed in this menu. The GGIO5 integer data values are received
via IEC 61850 GOOSE messages sent from other devices.
6.2.16 EGD PROTOCOL STATUS
a) FAST EXCHANGE
PATH: ACTUAL VALUES
Ö
STATUS
ÖØ
EGD PROTOCOL STATUS
Ö
PRODUCER STATUS
Ö
FAST EXCHANGE 1
These values provide information that may be useful for debugging an EGD network. The EGD signature and packet size
for the fast EGD exchange is displayed.
b) SLOW EXCHANGE
PATH: ACTUAL VALUES
Ö
STATUS
ÖØ
EGD PROTOCOL STATUS
Ö
PRODUCER STATUS
ÖØ
SLOW EXCHANGE 1(2)
These values provide information that may be useful for debugging an EGD network. The EGD signature and packet size
for the slow EGD exchanges are displayed.
IEC 61850
GOOSE UINTEGERS
UINT INPUT
1
0
MESSAGE
UINT INPUT
2
0
↓
MESSAGE
UINT INPUT 16
0
FAST EXCHANGE 1
FAST EXCHANGE 1
SIGNATURE:
0
MESSAGE
FAST EXCHANGE 1
DATA LENGTH:
0
SLOW EXCHANGE 1
SLOW EXCHANGE 1
SIGNATURE:
0
MESSAGE
SLOW EXCHANGE 1
DATA LENGTH:
0
Содержание G60 UR Series
Страница 2: ......
Страница 4: ......
Страница 12: ...xii G60 Generator Protection System GE Multilin TABLE OF CONTENTS ...
Страница 32: ...1 20 G60 Generator Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Страница 102: ...3 48 G60 Generator Protection System GE Multilin 3 4 MANAGED ETHERNET SWITCH MODULES 3 HARDWARE 3 ...
Страница 132: ...4 30 G60 Generator Protection System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Страница 392: ...5 260 G60 Generator Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Страница 418: ...6 26 G60 Generator Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Страница 446: ...8 18 G60 Generator Protection System GE Multilin 8 3 ENERVISTA SECURITY MANAGEMENT SYSTEM 8 SECURITY 8 ...
Страница 452: ...9 6 G60 Generator Protection System GE Multilin 9 1 PHASE DISTANCE THROUGH POWER TRANSFORMERS 9 THEORY OF OPERATION 9 ...
Страница 482: ...A 12 G60 Generator Protection System GE Multilin A 1 PARAMETER LISTS APPENDIXA A ...
Страница 604: ...D 10 G60 Generator Protection System GE Multilin D 1 IEC 60870 5 104 APPENDIXD D ...
Страница 616: ...E 12 G60 Generator Protection System GE Multilin E 2 DNP POINT LISTS APPENDIXE E ...
Страница 634: ...x G60 Generator Protection System GE Multilin INDEX ...