EVT-Pro Software – Test Valve/ Set Point Determination
Rev - 1.0 / Page 46 / 10/10/2012
Set Pressure:
allows for manual
determination of set
pressure. Click
then move cursor
onto the graph to
move the green set
pressure bar to the
desired location.
Reseat Pressure:
click to display a
representational
"best guess" of
the reseat
pressure. Actual
reseat pressure
cannot be
measured without
putting the valve
into full lift.
Click here to store the
current test to memory.
Remember three tests are
needed to pass a valve.
Starts a new test
without saving the
previous test to
memory.
Click here to go to
the test certificate
page.
Graph zoom
controls.
Set Pressure
Valve Passed/Failed