background image

5

Installation Instructions, Indoor Exhausting

     

ELBOWS HIGHLY

RECOMMENDED

ELBOW HIGHLY

RECOMMENDED

DO

6  ALCOVE OR CLOSET INSTALLATION

6  ALCOVE OR CLOSET INSTALLATION

 If your dryer is approved for installation in an alcove or 

  closet, it will be stated on a label on the dryer back.

 The dryer MUST be vented to the outdoors. See the 

  EXHAUST INFORMATION sections 3 & 4. 

 Minimum clearance between dryer cabinet and adjacent       

  walls or other surfaces is:

3 in. front and rear

 Minimum vertical space from floor to overhead cabinets, 

  ceiling, etc. is 52 in.

 Closet doors must be louvered or otherwise ventilated and 

  must contain a minimum of 60 sq. in. of open area equally 

  distributed. If the closet contains both a washer and a 

  dryer, doors must contain a minimum of 120 sq. in. of open 

  area equally distributed.

7  BATHROOM OR BEDROOM

INSTALLATION

• The dryer 

MU ST be vented to the outdoors. See 

  EXHAUST INFORMATION section 3 & 4.

• The installation must conform with local codes or, in the 

  absence of local codes, with the NATIONAL  ELECTRI-     
  CAL CODE, ANSI/NFPA NO. 70.

8  MOBILE OR MANUFACTURED

HOME INSTALLATION

       

 

 

 

 

 

• Installation must conform to the MA

NUFACTURED 

  HOME CONSTRUCTION & SAFETY STANDARD, 

  TITLE 24, PART 32-80 or, when such standard is not 

  applicable, with AMERICAN NATIONAL STANDARD 

  FOR MOBILE HOME, ANSI/NFPA NO. 501B.

• The dryer 

MUST be vented to the outdoors with the 

  termination securely fastened to the mobile home 

  structure. (See EXHAUST  INFORMATION

  section 3 & 4.)

• The vent 

MUST NOT be terminated beneath a mobile or 

  manufactured home.

• The vent duct material 

MUST BE METAL.

• 

Do not use sheet metal screws or other fastening devices 

  which extend into the interior of the exhaust vent.

• 

See section 2 for electrical connection information.

 

CONNECTING THE DRYER

TO HOUSE VENT

 

Rigid metal transitions ducts reduce the risk of crush-

ing and kinking.

 

Never install flexible metal duct in walls, ceilings, floors 

or other enclosed spaces.

 

For best drying performance, a rigid metal transition 

duct is recommended.

 

Avoid resting the duct on sharp objects.

 

In Canada and the United States, only the flexible 

metal(foil-type) ducts that comply with the “Outline for 

Clothes Dryer Transition Duct Subject 2158A” shall be 

used.

 

For many applications, installing elbows at both the 

dryer and the wall is highly recommended (see illustra-

tions below).  Elbows allow the dryer to sit close to the 

wall without kinking and or crushing the transition 

duct, maximizing drying performance.

 

Total length of flexible metal duct should not exceed 8 

feet (2.4m).

 RIGID METAL TRANSITION DUCT

 

If rigid metal duct cannot be used, then UL-listed 

flexible metal (semi-rigid) ducting can be used (Kit 

WX08X10077).

 

UL-LISTED FLEXIBLE METAL (SEMI-RIGID) TRANSITION DUCT

 

In special installations, it may be necessary to connect 

the dryer to the house vent using a flexible metal (foil- 

type) duct.  A UL-listed flexible metal (foil-type)duct 

may be used ONLY in installations where rigid metal or 

flexible metal (semi-rigid) ducting cannot be used AND 

where a 4" diameter can be maintained throughout the 

entire length of the transition duct.

 

Never install flexible metal duct in walls, ceilings, floors 

or other enclosed spaces.

 

Total length of flexible metal duct should not exceed 8 

feet (2.4m).

 

Avoid resting the duct on sharp objects.

 

For best drying performance:

 

1. Slide one end of the duct over the clothes dryer 

outlet pipe.

 

2. Secure the duct with a clamp.

 

3. With the dryer in its permanent position, extend the 

duct to its full length.  Allow 2” of duct to overlap the 

exhaust pipe.  Cut off and remove excess duct.  Keep 

the duct as straight as possible for maximum airflow.

 

4. Secure the duct to the exhaust pipe with the other 

clamp.

 UL-LISTED FLEXIBLE METAL (FOIL-TYPE) TRANSITION DUCT

0 in. either side

DO NOT

SIT DRYER

ON FLEXIBLE

EXHAUST.

DO NOT USE

EXCESSIVE

EXHAUST

LENGTH

DO NOT

CRUSH

FLEXIBLE

EXHAUST

AGAINST

WALL.

DON’T

Содержание DSLVR48EH

Страница 1: ...nstallation must be performed by a qualified installer Install the clothes dryer according to these instructions and in accordance with local codes This dryer must be exhausted to the outdoors Use only 4 rigid metal ducting for exhausting the clothes dryer to the outdoors Do not install or store this appliance in any location where it could be exposed to water and or weather Save these instruction...

Страница 2: ...y does not meet the above specifications then call a licensed electrician GROUNDING INSTRUCTIONS This dryer must be connected to a grounded metal permanent wiring system or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal on the appliance L1 N L2 RELOCATE GREEN GROUND SCREW HERE STRAIN RELIEF BRACKET GREEN OR YELLOW WIRE 3 4...

Страница 3: ... HOOD OR WALL CAP Terminate in a manner to prevent back drafts or entry of birds or other wildlife Termination should present minimal resistance to the exhaust air flow and should require little or no maintenance to prevent clogging Never install a screen in or over the exhaust duct This could cause lint build up Wall caps must be installed at least 12 in above ground level or any other obstructio...

Страница 4: ...ot terminate exhaust in a chimney a wall a ceiling gas vent crawl space attic under an enclosed floor or in any other concealed space of a building The accumulated lint could create a fire hazard Never terminate the exhaust into a common duct with a kitchen exhaust system A combination of grease and lint creates a potential fire hazard Do not use duct longer than specified in the exhaust length ta...

Страница 5: ...ever install flexible metal duct in walls ceilings floors or other enclosed spaces For best drying performance a rigid metal transition duct is recommended Avoid resting the duct on sharp objects In Canada and the United States only the flexible metal foil type ducts that comply with the Outline for Clothes Dryer Transition Duct Subject 2158A shall be used For many applications installing elbows a...

Страница 6: ... DESIRED KNOCKOUT ONE ONLY FIXING HOLE BEND TAB UP 45 9 A B ADDING NEW DUCT Reconnect the cut portion A of the duct to the blower housing Make sure that the shortened duct is aligned with the tab in the base Use the screw saved previously to secure the duct in place through the tab on the appliance base RIGHT OR LEFT SIDE EXHAUST PORTION A FIXING HOLE o Preassemble 4 elbow with 4 duct Wrap duct ta...

Страница 7: ...yer face half way With one hand holding the top of the door and the other hand holding the bottom remove the door from the dryer by lifting itUP and OUT 3 Rotate the door 180º Insert the door on the opposite side of the opening by moving the doorIN and DOWN until the top hinge and the bottom hinge are resting on the top screws inserted in step 1 4 Remove the remaining screws from the side of the o...

Страница 8: ...Notes ...