34
SD Series Reference Manual (x710 Mode)
MDS 05-4670A01, Rev. E
PORT [RS232, RS485]
COM2 Settings
Set or show
COM2
data port interface settings.
Push-to-Talk Delay
PTT [0–255]
This command sets or shows the key-up delay in milliseconds.
This timer specifies how long to wait after the radio receives a key
signal, before actually keying the radio.
Push-to-Talk
Configuration
PTTSIG [OFF, LOW, HI]
Used to set or show the configuration of the push-to-talk signal. This
signal is used for analog operation.
TX RF Power
Output Level
PWR [20–37]
NOTE:
This function might be restricted due to regulatory constraints.
This command displays or sets the desired RF forward output power set-
ting of the radio. The
PWR
command parameter is specified in dBm and
can range from 20 through 37. The default setting is 37 dBm (5 watts).
To read the actual (measured) power output of the radio, use the
SHOW
PWR
command. A dBm-to-watts conversion chart is provided in
RESTORECONFIG
Restore
Configuration
This command restores a user configuration. Command is timed and
aborts in 3 sec if no response is provided.
RESTOREDEFAULTS
Restore Defaults
This command restores the original factory configuration. Command is
timed and aborts in 3 sec if no response is provided.
RMODE [X710, TRANSPARENT, PACKET, CMAC, HELP]
Radio Mode
Allows the reconfiguration of the SD operating mode. An “MS” radio
model normally ships with x710 mode and provides the command inter-
face documented in this manual. Changing to a mode other than x710
causes the radio to exit the x710 command emulation interface and
prompt for a user login.
RSSI
Received Signal
Strength Indicator
This command continuously displays the
radio’s Received Signal
Strength Indication (RSSI) in dBm, until you press the Enter key.
Incoming signal strengths up to -60 dBm can be read.
Содержание DS-SD4-1
Страница 10: ...viii SD Series Reference Manual x710 Mode MDS 05 4670A01 Rev E ...
Страница 69: ...MDS 05 4670A01 Rev E SD Series Reference Manual x710 Mode 59 NOTES ...
Страница 70: ...60 SD Series Reference Manual x710 Mode MDS 05 4670A01 Rev E ...
Страница 74: ...MDS 05 4670A01 Rev E SD Series Reference Manual x710 Mode I 4 ...
Страница 76: ...GE MDS LLC Rochester NY 14620 Telephone 1 585 242 9600 FAX 1 585 242 9620 www gemds com 175 Science Parkway ...