Specifications
4-5
March 2008
Transducer (cont.)
Housing Options:
Explosion-proof (Class I, Group C & D, Division I)
Flameproof (INIEX/ISSeP certified for EEx d II C T6)
Weatherproof (Type-4X, IP65)
Type-7
Flowcell
The flowcell specifications for the Model GS868 flowmeter are
divided into the following categories:
Spoolpiece
Process Connections:
Flanged typical, welded optional
Transducer Connections
:
1.5 in., 300 lb. flange for T9 transducer
1.5 in., 150-2,500-lb. flange for BWT transducers
Cold Tap
Process Connections:
N/A
Transducer Connection:
PanaPort cold tap kit
Optional: ANSI flanged 150 to 300#
Pipe Size & Materials
Outside Diameter (OD):
2 to 48 in. (50 to 1200 mm).
Materials:
All metals. Consult GE for other materials.