DigitalFlow™ GF868 Programming Manual (2-Channel)
41
Chapter 2. Displaying Data
2.3 The DUAL Submenu
The
DUAL
format displays two measurements simultaneously in normal print. To select the
DUAL
format and the
measurements to display in this format, follow the instructions in this section.
Upon power up, a standard measurement mode display (similar to the one shown below) appears in
BIG
format. Press
the appropriate side of the
[SCREEN]
key to activate the desired pane of the display screen, and complete the following
steps:
1.
To access the
Display Menu
, press the
[DISP]
key.
2.
Press
[F2]
=
DUAL
. The measurement mode display reappears and the display is now in the
DUAL
format.
3.
Use the
[F1]-[F4], [
and [
keys to select the desired display parameter option. See Table 9 on page 40 for a
complete description of the available options.
Note:
See Chapter 3,
Operation
, of the
Startup Guide
for more details on selecting a measurement parameter to
display.
With the
DUAL
format display screen active, when a measurement parameter is selected, the top line of the prompt area
will be changed to show that parameter. The parameter previously displayed at the top of the display is moved to the
bottom of the display, and the previous bottom parameter is no longer shown.
2.4 The GRAPH Submenu
The
GRAPH
submenu permits the display of either the flow velocity, mass flow or the volumetric flow on an XY bar
graph, with a specified time interval on the x-axis. This section describes the procedures for setting up and using the
graph format.
2.4.1 Setting Up the GRAPH Format
Press the appropriate side of the
[SCREEN]
key to activate the desired pane of the display screen, and complete the
following steps:
1.
To access the
Display Menu
, press the
[DISP]
key.
2.
Press
[F3]
=
GRAPH
.
3.
Press
[F1]-[F3]
to graph the
Flow Velocity
,
Volumetric Flow
or
Mass Flow
, respectively.
4.
Use the
[
, [
and
[F1]-[F4]
keys to select the desired
Time Increment
.
5.
Enter a maximum value for the
Y-axis
(vertical) scale that is larger than the maximum expected reading and press
[ENT]
.
6.
At the
Y Range
prompt, press
[F1]
to graph only positive Y values or press
[F2]
to graph both positive and negative
Y values.
After the
Y RANGE
is entered, the Model GF868 automatically begins taking measurements and displays them in the
specified graphical format. Proceed to the next section for a discussion of manipulating the graphical display.
Содержание DigitalFlow GF868
Страница 2: ......
Страница 4: ...ii no content intended for this page ...
Страница 10: ...Contents viii DigitalFlow GF868 Programming Manual 2 Channel no content intended for this page ...
Страница 60: ...Chapter 2 Displaying Data 50 DigitalFlow GF868 Programming Manual 2 Channel no content intended for this page ...
Страница 95: ...DigitalFlow GF868 Programming Manual 2 Channel 85 Appendix A Menu Maps Appendix A Menu Maps ...
Страница 96: ...86 DigitalFlow GF868 Programming Manual 2 Channel no content intended for this page ...
Страница 104: ...Appendix A Menu Maps DigitalFlow GF868 Programming Manual 2 Channel 94 ...
Страница 108: ...98 DigitalFlow GF868 Programming Manual 2 Channel no content intended for this page ...
Страница 146: ...Warranty 136 DigitalFlow GF868 Programming Manual 2 Channel no content intended for this page ...
Страница 150: ......
Страница 151: ......