DigitalFlow™ GF868 Programming Manual (2-Channel)
53
Chapter 3. Logging Data
3.2 Creating a Standard Log (cont.)
Refer to Chapter 3,
Diagnostics
, of the
Service Manual
for a discussion of the many parameters accessible via the
DIAG
option.
Note:
The units assigned to the parameters in Table 16 on page 52 are those selected in the
User Program
(
SYSTM
submenu)
.
6.
Use the [
, [
and
[F1]-[F4]
keys to select the second parameter to be logged.
7.
Use the [
, [
and
[F1]-[F4]
keys to select the third parameter to be logged.
•
If you selected a totalized value for display, go to step 8.
•
If you did not, go to step 9.
8.
At the
Set Log Totals to 0
prompt, press
[F1]
to leave the log totals at their present value or press
[F2]
to reset the log
totals to zero. Choosing
YES
at this prompt only resets the log totals to zero and has no effect on the meter totals.
3.2.1 Log Type
9.
Press
[F1]
to create a non-circular log or press
[F2]
to create a circular log.
A non-circular log automatically stops when the meter runs out of memory or the specified
END TIME
is reached. A
circular log runs continuously until manually stopped, but only the data from the most recent log cycle is saved. At the
start of each cycle, the oldest recorded data is overwritten by the new data from the current cycle.
3.2.2 STARTTIME Prompt
10.
Press
[F1]
to accept the displayed start time or press
[F2]
to enter a different start time. To start logging immediately,
press
[F3]
.
•
If
OK
was selected, proceed to step 11.
•
If
NOW
was selected, proceed to step 12 if you selected a the non-circular log or to step 14 for a circular log.
•
If
EDIT
was selected, complete the steps listed below.
a.
Press
[F1]-[F2]
to select
AM
or
PM
. Then, enter the desired
Hour
(1-12) and press
[ENT]
. (Entry of a start time
earlier than the current time will generate an error message.)
b.
Enter the desired
Minutes
and press
[ENT]
. The acceptable range is 0 to 59.
c.
Enter the desired
Seconds
and press
[ENT]
. The acceptable range is 0 to 59.
CAUTION! If data from one circular log cycle exceeds the meter’s memory capacity, the
earliest logged data will be lost.
Содержание DigitalFlow GF868
Страница 2: ......
Страница 4: ...ii no content intended for this page ...
Страница 10: ...Contents viii DigitalFlow GF868 Programming Manual 2 Channel no content intended for this page ...
Страница 60: ...Chapter 2 Displaying Data 50 DigitalFlow GF868 Programming Manual 2 Channel no content intended for this page ...
Страница 95: ...DigitalFlow GF868 Programming Manual 2 Channel 85 Appendix A Menu Maps Appendix A Menu Maps ...
Страница 96: ...86 DigitalFlow GF868 Programming Manual 2 Channel no content intended for this page ...
Страница 104: ...Appendix A Menu Maps DigitalFlow GF868 Programming Manual 2 Channel 94 ...
Страница 108: ...98 DigitalFlow GF868 Programming Manual 2 Channel no content intended for this page ...
Страница 146: ...Warranty 136 DigitalFlow GF868 Programming Manual 2 Channel no content intended for this page ...
Страница 150: ......
Страница 151: ......