![GE DigitalFlow GC868 Скачать руководство пользователя страница 114](http://html.mh-extra.com/html/ge/digitalflow-gc868/digitalflow-gc868_programming-manual_128362114.webp)
April 2008
6-2
Serial Communications
Checking the GC868
Baud Rate
For successful serial communications, the GC868 and the personal
computer must be set up to send/receive data at the same speed. To
verify or change the
baud rate
setting of the GC868, proceed as
follows:
Access the
User Program
, by pressing the
[PROG]
key on the keypad.
The standard measurement mode screen will be replaced by the
following initial programming mode screen:
The available rates are 300, 600, 1200, 2400, 4800, 9600 and 19200
baud. After verifying or changing the baud rate setting, press the
[EXIT]
key twice to return to standard measurement mode.
Note:
Refer to Chapter 1,
Programming Site Data
, for a detailed
description of using the
COMM
submenu on page 1-44. The
description includes information on checking UART bits and
network ID.
Setting Up the Terminal
Software and
Transferring Data
Specific instructions are given in this manual for communicating with
personal computers running under the Windows 9X/NT (page 6-3)
operating systems. Proceed to the appropriate section for detailed set
up procedures.
Note:
For computers operating under other operating systems,
contact the factory for assistance or consult the operating
system manual supplied with the computer.
PROGRAM Start
Press the [
←]
and [
→]
keys and
the
[F3]
key to select the
COMM
submenu.
PROGRAM
status
SETUP CLOCK COMM
SAVE
COMM PROGRAM
To change the baud rate, press
the [
→]
key until the desired
baud rate appears on the option
bar, and then press the
appropriate
[Fx]
function key.
PROGRAM
Comm port
BAUD RATE
current setting appears here
4800
9600
19200
Содержание DigitalFlow GC868
Страница 8: ...Chapter 1 ...
Страница 61: ...Chapter 2 ...
Страница 78: ...Chapter 3 ...
Страница 91: ...Chapter 4 ...
Страница 105: ...Chapter 5 ...
Страница 106: ...Clearing Data Introduction 5 1 Reset Totals 5 2 Deleting Site Files 5 3 Deleting Log Files 5 4 ...
Страница 111: ...Chapter 6 ...
Страница 123: ...Appendix A ...
Страница 132: ...Appendix B ...
Страница 133: ...Data Records Option Cards Installed B 1 Initial Setup Data B 2 ...
Страница 136: ...Appendix C ...
Страница 156: ...Appendix D ...