Product 
Summary

The Dialog

 Telephone Interface Module (DTIM) is a battery operated communication link 

between the security system control panel and the central monitoring station. The DTIM 
receives radio signals from the panel, then uses the phone line to report security system events to 
the central monitoring station.

The DTIM provides added security by separating the telephone interface from the panel. If the 
panel is damaged during a break-in or fire, the DTIM can still report to the central monitoring 
station.

The DTIM is a supervised device that transmits supervisory signals every hour for the panel to 
receive. When the battery is low, the module transmits a low battery signal.

Note  

The DTIM does not have a backup power supply. Therefore, the battery must be replaced within 7 days 
when a low battery condition occurs to ensure that system events can be reported. If the battery is 
allowed to completely drain, the panel identifies the DTIM as being in a supervisory (non-working) 
state, which prevents system events from being reported.

Tools and Supplies Needed

Phillips screwdriver

Mounting Hardware (included)

Ty-wrap and Cover Screw for UL Listed installations (included)

Installation

This section describes guidelines for installing the DTIM, programming, testing, mounting, and 
phone line connections.

Installation Guidelines

Before permanently mounting to a wall, test the DTIM from the desired location to ensure 
communication with the panel. This means you must first add (learn) the DTIM into panel 
memory, then perform a sensor test.

Mount the module within 100 feet of the panel, but not closer than 10 feet to another DTIM 
or the panel.

Always mount the DTIM in the upright vertical position.

The DTIM can be connected to a standard analog (loop-start) phone line, with or without 
digital subscriber line (DSL) service.

Note  

The DTIM cannot be used on digital or PBX phone lines, which are designed only for digital type 
devices that operate anywhere from 5 volts DC and up. The DTIM uses an analog modem and does 
not have a digital converter, adapter, or interface to operate with such systems.

When connecting the DTIM to the phone line, it is recommended that you install an RJ-31X 
jack (CA-38A in Canada) ahead of all phones and other devices on the line for full line sei-
zure. This allows the DTIM to take control of the phone line when an alarm occurs, even if 
the phone is in use or off-hook. It also provides customers with a quick disconnect in case the 
DTIM malfunctions, allowing them to use their phone.

For UL Listed installations, mount the RJ-31X jack within 5 feet of the DTIM.

'RFXPHQW1XPEHU5HY'

-XQH

'LDORJ7HOHSKRQH,QWHUIDFH

0RGXOH

0RGHO1R5

Содержание Dialog

Страница 1: ...tion describes guidelines for installing the DTIM programming testing mounting and phone line connections Installation Guidelines Before permanently mounting to a wall test the DTIM from the desired location to ensure communication with the panel This means you must first add learn the DTIM into panel memory then perform a sensor test Mount the module within 100 feet of the panel but not closer th...

Страница 2: ...y to success with step 5 Read the complete step before you begin to help ensure successful programming Do not wait more than 1 second between tamper switch activa tions in step 5 If you wait too long the LED will not flash and you must start over Also do not release the tamper switch before the LED is done flashing or you must start over 5 Press and release the DTIM tamper switch as follows Press ...

Страница 3: ...ng by announcing the sensor number name and group Refer to the Simon Security System Installation Instructions for more information on programming the DTIM with a Simon panel Testing DTIM Transmitting Range The following describes the basic steps for testing transmitting range from the DTIM to the panel For complete testing instructions see the panel installation instructions Note Be sure to attac...

Страница 4: ... use Note For UL Listed systems the RJ 31X jack must be mounted within 5 feet of the DTIM An RJ 31X CA 38A jack should be installed when wiring for full line seizure This lets the user quickly and easily disconnect the DTIM from the phone line in case the DTIM disables the phone line due to a malfunction 1 Run a 4 conductor cable from the TELCO block to the RJ 31X A in Figure 4 2 Connect the 4 con...

Страница 5: ...tation The following steps describe the basic steps for conducting a phone test Refer to the specific panel installation instructions for complete details Note You must conduct a phone test whenever the DTIM bat tery is replaced 1 Call the central monitoring station to inform them you are testing the system 2 Make sure the panel has the correct account number and central station receiver phone num...

Страница 6: ... the battery if necessary Use an RF Sniffer 60 401 to verify that the DTIM is transmitting remove and replace the DTIM cover to cause a transmission Verify that the DTIM was added learned into panel memory correctly Relocate the DTIM to a different location Trouble Condition If the panel indicates a Tamper condition for this device check that the cover is securely in place and that the spring is o...

Страница 7: ... the REN is separately shown on the label A plug and jack used to connect this equipment to the premises wiring and telephone network must comply with the appli cable FCC Part 68 rules and requirements as adopted by ACTA A compliant telephone cord and modular plug is provided with this product It is designed to be connected to a compliant modular jack that is also compliant See the Installation In...

Страница 8: ...mber 0 3B AC The term IC before the certification registration number only signifies that the Industry Canada technical specifications were met IC 867A 12000 AVIS L étiquette du ministère des Communications du Canada identifie le matériel homologué Cette étiquette certifie que le matériel est conforme a certaines normes de protection d exploitation et de sécurité des réseaux de télécommuni cations...

Отзывы: