12
Installation Instructions
MAKING THE LP CONVERSION
1 SAFETY INFORMATION YOU
SHOULD KNOW
The pressure regulator and burner orifices are set
for natural gas. To use LP gas, the regulator and
burner orifices must be converted. The LP orifice
spuds for the cooktop burners can be located in the
literature package attached to the regulator.
CAUTION:
The cooktop, as shipped from
the factory, is set for use with natural gas. If you
wish to use your cooktop with LP gas, you must
first replace the orifices and convert the pressure
regulator.
WARNING:
This conversion must be
performed by a qualified installer or gas supplier in
accordance with the manufacturer’s instructions
and all codes and requirements of the authority
having jurisdiction. Failure to follow instructions
could result in serious injury or property damage.
The qualified agency performing this work assumes
responsibility for the conversion.
CAUTION:
The following adjustments
must be made before turning on the burner. Failure
to do so could result in serious injury. Be sure
pressure regulator has been converted as
described in Step 2.
2 ADJUST YOUR COOKTOP FOR USE
WITH LP GAS
A Disconnect all electrical power, at the main
circuit breaker or fuse box.
B Shut off the gas supply to the cooktop
by closing the manual shut-off valve.
C Adjust the pressure regulator, by the following
instructions:
• Unscrew the cap.
• Place your thumb against the flat side of the
spring retainer and press down to remove
the retainer.
• Carefully look at the spring retainer to locate
the NAT or LP position.
• Turn the spring retainer over so that LP is
showing on the bottom.
• Snap the retainer back into position.
• Screw the cap back onto the regulator.
DOWN
FOR OFF
NAT
LP
LP
NAT
LP
NAT
NAT
LP
Gasket
Cap
Spring
Retainer
L.P./Propane
Position
NAT.
Position
Pressure Regulator
TOOLS YOU WILL NEED
FOR LP CONVERSION
Safety Glasses
Small Flat-Head
Screwdriver (4mm or
5/32
″
tip size, 60mm
long)
7mm Nutdriver