Alarms
Configuration warning. Displays when the priority setting for
Tachy/Brady PR
high/low
or
HR/PR high/low
, or
SpO2 low
has been set to low. Check the alarm
configuration. Displays in the upper left corner of the alarm area.
General warning sign. Displays when the priority setting for
Tachy/Brady PR
high/low
or
HR/PR high/low
, or
SpO2 low
has been set to low. Displays in the
lower part of the parameter menus’
Alarms
tab, and in the
Priority
column of
the selected alarm in the
Alarm Setup
>
Alarm Priorities
.
Alarm priority indicator: High (red). Indicates a high priority alarm.
Alarm priority indicator: Medium (yellow). Indicates a medium priority alarm.
Alarm priority indicator: Low (cyan). Indicates a low priority alarm.
Alarm volume indicator. Adjust the minimum alarm tone volume.
Description of alarm and information messages
Alarm and information messages can be displayed in three areas:
●
The parameter window
●
The waveform field
●
Alarm area (upper part of the screen)
In the alarm area, up to five alarm or information messages may be displayed from
left to right, from the newest highest priority alarm to the oldest lowest priority alarm.
Up to four newest highest priority remote alarm messages display first, followed by
the newest highest priority local alarm messages.
Alarm and information messages are stored in the clinical logs. Access to the
clinical logs is a service-level function and it is password protected. The alarm and
information messages stored in the clinical logs include:
●
Time of occurrence
●
Alarm or information message text
●
Current value and the associated alarm limit if a limit alarm (local only)
134
CARESCAPE Modular Monitors
2062971-001
Содержание CARESCAPE
Страница 38: ...38 CARESCAPE Modular Monitors 2062971 001 ...
Страница 114: ...Setting up the monitor before use 114 CARESCAPE Modular Monitors 2062971 001 ...
Страница 146: ...Alarms 146 CARESCAPE Modular Monitors 2062971 001 ...
Страница 218: ...Pulse oximetry 218 CARESCAPE Modular Monitors 2062971 001 ...
Страница 234: ...Non invasive blood pressure 234 CARESCAPE Modular Monitors 2062971 001 ...
Страница 260: ...Temperature 260 CARESCAPE Modular Monitors 2062971 001 ...
Страница 274: ...Cardiac output 274 CARESCAPE Modular Monitors 2062971 001 ...
Страница 280: ...Mixed venous oxygen saturation SvO 280 CARESCAPE Modular Monitors 2062971 001 ...
Страница 322: ...CO2 with CAPNOSTAT Mainstream CapnoFlex LF and Dual CO2 modules 322 CARESCAPE Modular Monitors 2062971 001 ...
Страница 338: ...Patient Spirometry 338 CARESCAPE Modular Monitors 2062971 001 ...
Страница 372: ...Neuromuscular transmission 372 CARESCAPE Modular Monitors 2062971 001 ...
Страница 404: ...Laboratory data 404 CARESCAPE Modular Monitors 2062971 001 ...
Страница 410: ...Calculations 410 CARESCAPE Modular Monitors 2062971 001 ...
Страница 416: ...Drug calculations 416 CARESCAPE Modular Monitors 2062971 001 ...
Страница 424: ...Trends 424 CARESCAPE Modular Monitors 2062971 001 ...
Страница 432: ...Snapshots and events 432 CARESCAPE Modular Monitors 2062971 001 ...
Страница 462: ...Cleaning and care 462 CARESCAPE Modular Monitors 2062971 001 ...
Страница 528: ...Abbreviations yr year yrs years 528 CARESCAPE Modular Monitors 2062971 001 ...
Страница 546: ...Skills checklist 546 CARESCAPE Modular Monitors 2062971 001 ...
Страница 547: ...content ...