GE Multilin
B90 Low Impedance Bus Differential System
B-49
APPENDIX B
B.4 MEMORY MAPPING
B
CAD8
Direct Input/Output Channel 2 CRC Alarm Function
0 to 1
---
1
F102
0 (Disabled)
CAD9
Direct I/O Channel 2 CRC Alarm Message Count
100 to 10000
---
1
F001
600
CADA
Direct Input/Output Channel 2 CRC Alarm Threshold
1 to 1000
---
1
F001
10
CADB
Direct Input/Output Channel 2 CRC Alarm Events
0 to 1
---
1
F102
0 (Disabled)
CADC
Reserved (4 items)
1 to 1000
---
1
F001
10
CAE0
Direct I/O Ch 1 Unreturned Messages Alarm Function
0 to 1
---
1
F102
0 (Disabled)
CAE1
Direct I/O Ch 1 Unreturned Messages Alarm Msg Count
100 to 10000
---
1
F001
600
CAE2
Direct I/O Ch 1 Unreturned Messages Alarm Threshold
1 to 1000
---
1
F001
10
CAE3
Direct I/O Ch 1 Unreturned Messages Alarm Events
0 to 1
---
1
F102
0 (Disabled)
CAE4
Reserved (4 items)
1 to 1000
---
1
F001
10
CAE8
Direct IO Ch 2 Unreturned Messages Alarm Function
0 to 1
---
1
F102
0 (Disabled)
CAE9
Direct I/O Ch 2 Unreturned Messages Alarm Msg Count
100 to 10000
---
1
F001
600
CAEA
Direct I/O Ch 2 Unreturned Messages Alarm Threshold
1 to 1000
---
1
F001
10
CAEB
Direct I/O Channel 2 Unreturned Messages Alarm Events
0 to 1
---
1
F102
0 (Disabled)
CAEC
Reserved (4 items)
---
---
1
F001
10
Remote Devices (Read/Write Setting) (32 modules)
CB00
Remote Device 1 GSSE/GOOSE Application ID
---
---
---
F209
“Remote Device
1“
CB21
Remote Device 1 GOOSE Ethernet APPID
0 to 16383
---
1
F001
0
CB22
Remote Device 1 GOOSE Dataset
0 to 16
---
1
F184
0 (Fixed)
CB23
Remote Device 1 in PMU Scheme
0 to 1
---
1
F126
0 (No)
CB24
Undefined
0 to 3
---
1
F626
0 (None)
CB25
...Repeated for Device 2
CB4A
...Repeated for Device 3
CB6F
...Repeated for Device 4
CB94
...Repeated for Device 5
CBB9
...Repeated for Device 6
CBDE
...Repeated for Device 7
CC03
...Repeated for Device 8
CC28
...Repeated for Device 9
CC4D
...Repeated for Device 10
CC72
...Repeated for Device 11
CC97
...Repeated for Device 12
CCBC
...Repeated for Device 13
CCE1
...Repeated for Device 14
CD06
...Repeated for Device 15
CD2B
...Repeated for Device 16
CD50
...Repeated for Device 17
CD75
...Repeated for Device 18
CD9A
...Repeated for Device 19
CDBF
...Repeated for Device 20
CDE4
...Repeated for Device 21
CE09
...Repeated for Device 22
CE2E
...Repeated for Device 23
CE53
...Repeated for Device 24
CE78
...Repeated for Device 25
CE9D
...Repeated for Device 26
CEC2
...Repeated for Device 27
CEE7
...Repeated for Device 28
CF0C
...Repeated for Device 29
CF31
...Repeated for Device 30
CF56
...Repeated for Device 31
CF7B
...Repeated for Device 32
Table B–9: MODBUS MEMORY MAP (Sheet 42 of 48)
ADDR
REGISTER NAME
RANGE
UNITS
STEP
FORMAT
DEFAULT
Содержание B90 UR Series
Страница 28: ...1 20 B90 Low Impedance Bus Differential System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Страница 114: ...4 28 B90 Low Impedance Bus Differential System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Страница 272: ...6 14 B90 Low Impedance Bus Differential System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Страница 316: ...A 4 B90 Low Impedance Bus Differential System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Страница 406: ...B 90 B90 Low Impedance Bus Differential System GE Multilin B 4 MEMORY MAPPING APPENDIX B B ...
Страница 436: ...C 30 B90 Low Impedance Bus Differential System GE Multilin C 7 LOGICAL NODES APPENDIX C C ...
Страница 446: ...D 10 B90 Low Impedance Bus Differential System GE Multilin D 1 IEC 60870 5 104 APPENDIX D D ...