background image

se and Care&Installation Guide

Air Conditioner

Adapter Plug

Model and Serial Numbers

Air Direction

Moisture Removal

Air Filter

5

Problem Solver

10

 Registration

2

 Instructions

2

Care and Cleaning

User Maintenance Instructions 5

Condenser Coils

5

Back Cover

Consumer Services

11

Control Settings

4

Electrical Requirements

3

 Tips

6

Extension Cords
Grille and Cabinet

5

Grounding

GE Answer Center

a

Installation Instructions

800.626.2000

Portable Models

GE Appliances

Содержание APM04

Страница 1: ...ance Registration 2 Safe Instructions 2 Care and Cleaning 5 User Maintenance Instructions 5 Condenser Coils 5 Warran Back Cover Consumer Services 11 Control Settings 4 Electrical Requirements 3 Ener Saving Tips 6 Extension Cords 3 Grille and Cabinet 5 Grounding GE Answer Centera Installation Instructions 7 800 626 2000 Portable Models APM04 APM05 GE Appliances ...

Страница 2: ...This air conditioner must be properly installed in accordance with the Installation Instructions before it is used See grounding instructions on page 3 c Never unplug your air conditioner by pulling on the power cord Always grip plug firmly and pull straight out from the receptacle Repair or replace immediately all electric service cords that have become frayed or otherwise damaged Do not use a co...

Страница 3: ...DO NOT UNDER ANY CIRCUMSTANCES CUT OR REMOVE THE THIRD GROUND PRONG FROM THE POWER CORD properly grounded two prong wdl outlet by use of a UL listed adapter Fig 2 available at most Iocd hardware stores PR ER u FIRM CONNECTION Fig 2 BEFORE USE The larger slot in the adapter must be aligned with the larger slot in the wall outlet to provide proper polarity in the connection of the power cord CAUTION...

Страница 4: ...es cooling with low fan speed operation For normal cooling For matimum cooling 1 Set the Selector at HI COOL temperature is not satisfactory 1 Set the Selector at HI COOL 2 Set the Thermostat at desired tifter a reasonable time set the number usually the midpoint is a Thermostat Control at a higher 2 Set the Thermostat at 10 good starting position If room number for a cooler room or at a lower num...

Страница 5: ... the air filter fits into a slot at the front of the air discharge louvers Remove the filter by grasping its top corners and pulling up and out On the APM05 model the air filter fits in a slot behind an access door located on the front top of the air conditioner Remove the t ilter by opening the access door grasping the filter and pulling up and out ir Filter Use a vacuum cleaner to clean the filt...

Страница 6: ...ition Keep windows and doors closed Cool dry air escapes when they re open Keep furnace floor registers and cold air returns closed Cold air can easily escape through them Don t let drapes or furniture block the front of the unit and restrict air flow when it is operating It s best to operate your air conditioner at high speed during extremely hot weather Keep outdoor condenser coil clean Turn air...

Страница 7: ...pply provided does not meet the above specifications call a licensed electrician Aluminum house wiring may pose special problems consult a qualified electrician SAVE THE CARTON For convenient storage of air conditioner during winter months or when not in use TOOLS NEEDED Phillips screwdriver I nife or Scissors Flat Blade screwdriver Ruler WINDOW REQUIREMENTS Standard double hung window with actual...

Страница 8: ...dow Wood Filler Strips L lNS LLATION N WINDOW 1 Center the unit in the window opening Keeping a firm grip on the air conditioner carefully put the bottom rail between the window stool and the locator If the locator is too short to hold the unit in position insert a filler strip to raise it Bottom tor Rail Strip ed 2 Lower the window sash tight against the sliding panels and the rear of the grille ...

Страница 9: ...emove foam sash gap gasket from between windows 3 Remove screws securing the sliding panels to the lower sash and window stool Close sliding panels 4 Keeping a firm grip on the air conditioner raise sash and carefully rock air conditioner backward to drain the major portion of any condensate water in the base of the unit Carefully lift the unit from the window to avoid spilling any remaining water...

Страница 10: ...urned on Allow time for it to cool down Cold air may be escaping through open furnace floor registers and cold air returns Cooling coils have iced up To melt ice set the Selector Switch to HI FAN or HI COOL with the Thermostat Control to 1 or 2 Thermostat click a metallic sound may be heard when compressor cycles on and off This is normal Fan runs continuously when Selector Switch is in COOL or FA...

Страница 11: ...n have needed parts or accessories sent direcdy to their home free of shipping charge The GE parts system provides access to over 47 000 parts and dl GE Genuine Renewal Parts are fully warranted WSA MasterCard and Discover cards are accepted User maintenance instructions contained in this boo et cover proce dures intended to be performed by any user Other servicing genedy shodd be referred to quti...

Страница 12: ...TORY SERVICE or GENERAL ELECTRIC CUSTOMER CARE SERVICE WHAT IS NOT COVERED Service trips to your home to teach you how to use the product Read your Use and Care material If you then have any questions about operating the product please contact your dealer or our Consumer Affairs office at the address below or call toll free GE Answer Center 800 626 2000 Improper installation If you have an install...

Отзывы: