6.1.4 Main Menu Mode
The keypad provides access to the main menu mode.
Select the Main Menu mode by pressing the [Main Menu]
key. Illustration 6.2 shows the resulting read-out, which
appears on the display of the keypad.
Lines 2 through 5 on the display show a list of parameter
groups which can be chosen by toggling the up and down
buttons.
Illustration 6.8 Display example.
Each parameter has character(s) and number which remain
the same regardless of the programming mode. In the
Main Menu mode, the parameters are further divided into
groups: Macros, Keypad Set-Up, Parameter Data Set,
Parameter Data Check, Drive Information, Data Readouts,
Logs & I/O Option Status, and Advanced Parameter Data
Set.
All parameters can be changed in the Main Menu. The
configuration of the unit (
H-40 Configuration Mode
) will
determine other parameters available for programming.
For example, selecting Closed Loop enables additional
parameters related to closed loop operation. Option cards
added to the unit enable additional parameters associated
with the option device.
6.1.5 Parameter Selection
Main Menu Item
Parameter Groups:
Keypad Set-Up
K-##
Parameter Data
Set
F-##, E-##, C-##, P-##, H-##, AN-##, SP-##, O-
##, AO-##, DN-##, PB-##, LN-##, BN-##
Drive Information ID-##
Data Readouts
DR-##
Logs & I/O Option
Status
LG-##
Advanced
Parameter Data
Set
AP-##, FB-##, T-##, CL-##, XC-##, PC-##, LC-##,
B-##
Table 6.3 Parameter Groups in Main Menu Items
Group no.
Parameter group:
K-##
Keypad Set-Up
F-##
Fundamental Parameters
E-##
Digital In/Out
C-##
Frequency Control Functions
P-##
Motor Data
H-##
High Perf Parameters
AN-##
Analog In/Out
SP-##
Special Functions
O-##
Options / Comms
AO-##
Analog I/O Option
DN-##
DeviceNet
PB-##
Profibus
LN-##
LonWorks
BN-##
BACnet
ID-##
Drive Information
DR-##
Data Readouts
LG-##
Logs & I/O Opt. Status
AP-##
HVAC Appl. Param.
FB-##
Fire/Bypass Operation
EN-##
EtherNet
T-##
Timed Functions
CL-##
PID Closed Loop
XC-##
Ext. PID Closed Loop
PC-##
Pump Controller
LC-##
Logic Controller
B-##
Braking Functions
Table 6.4 Parameter groups.
Choose a parameter group from the Main Menu and Press
[OK]. Then further select the parameter sub-groups by
using the up and down arrows and then Press [OK].
The middle section of the keypad display shows the
parameters. Press [OK] to select parameters and now the
display shows that selected parameter's value.
6.1.6 Changing Data
1.
Press [Quick Menu] or [Main Menu] key.
2.
Use [
▲
] and [
▼
] keys keys to find parameter
group to edit.
3.
Press [OK] key.
4.
Use [
▲
] and [
▼
] keys to find parameter to edit.
5.
Press [OK] key.
6.
Use [
▲
] and [
▼
] keys to select correct parameter
setting. Or, to move to digits within a number,
use left or right arrow keys. Cursor indicates digit
selected to change. [
▲
] key increases the value,
[
▼
] key decreases the value.
7.
Press [Cancel] key to disregard change, or press
[OK] key to accept change and enter new setting.
How to Program
AF-600 FP High Power Operating Instructions
81
6
6
Содержание AF-600 FP Series
Страница 44: ...Please note airflow directions Mechanical Installation AF 600 FP High Power Operating Instructions 43 4 4...
Страница 45: ...Please note airflow directions Mechanical Installation AF 600 FP High Power Operating Instructions 44 4 4...
Страница 46: ...Please note airflow directions Mechanical Installation AF 600 FP High Power Operating Instructions 45 4 4...